ICP-AES determination of minor and major elements in Cornelian cherry (Cornus mas L.) after microwave assisted digestion

被引:22
|
作者
Juranovic Cindric, Iva [2 ]
Zeiner, Michaela [1 ]
Krpetic, Martina [2 ]
Stingeder, Gerhard [1 ]
机构
[1] Univ Nat Resources & Life Sci, Dept Chem, Div Analyt Chem, A-1190 Vienna, Austria
[2] Univ Zagreb, Fac Sci, Dept Chem, Analyt Chem Lab, Zagreb 10000, Croatia
关键词
ICP-AES; Microwave assisted digestion; Minor and major elements; Cornelian cherry; Cornus mas L; FRUITS; ANTHOCYANINS;
D O I
10.1016/j.microc.2012.03.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inductively coupled plasma atomic emission spectrometry (ICP-AES) was used for the determination of minor and major elements present in Cornelian cherry (Cornus mas L). as this fruit and its preservatives may be considered as important nutritional supplements. Prior to ICP-AES measurement, the samples were digested in a microwave assisted digestion system. The ICP-AES method was validated and optimized for the determination of selected elements in Cornelian cherry. The accuracy of the method as estimated through by spiking experiments was satisfactory, the recoveries obtained after microwave digestions in whole fruit (A), mesocarp (B) seed (C), and juice ranged from 84-123%, 74-115% 82-124%, and from 83-116% respectively. For microwave assisted digested Cornelian cherry samples of whole fruit (A), mesocarp (B) and seeds (C) the following limits of detection were obtained <2 ng/g for Al, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sr, Zn, Mg, and K. moderate 2-10 ng/g for B, and Ca. The highest LODs were obtained only for Al in mesocarp (B) and seeds (C) compared with whole fruit (A). For microwave assisted digested Cornelian cherry juice the limits of detection were in the range 0.04-0.108 mu g/L. The precision of the method was evaluated using the standard deviation, RSD, of repeated determinations of the analytes and for all elements RSD ranged from 0.5 to 7% except for Na 12%. The intermediate precision (< 4.8%), the day-to-day reproducibility (< 6.8%), and the overall uncertainty of measurement (approx. 4-10%) for all elements analyzed demonstrated the good applicability of the chosen microwave assisted digestion procedure. Regarding potentially toxic elements, Cu and Pb are below 4 mu g/g in the whole berry. Cr and Cd were not even detected.The order of magnitude of the concentrations for the elements found in whole fruit (whole fruit, A) and seed (C) is found to be similar for most of the elements of interest, namely in mu g/g: 2.52 and 6.0 B, 2074.4 and 3971.8 Ca, 2.4 and 2.4 Cu, 7.8 and 4.1 Fe, 4019 and 3288K, 288 and 237 Mg, 1.65 and 3.1 Mn, 22.9 and 41 Na, 9.0 and 6.9 Ni, 2.9 and 3.3 Pb, 6.9 and 12.5 Sr, respectively. In Cornelian cherry juice the content of Al, Ba, Cd, Cr, Cu, Mn, Pb, and Sr were below the limits of detection (0.06, 0.07, 0.07, 0.006, 0.01, 0.042, 0.056, 0.04 and 0.009 mu g/L, respectively). The content of minor elements was 0.135 Fe, 0.163 Ni, 0.828 Zn and 1.47 mg/L B. The concentrations of major elements were 11.3 Na, 51.7 Ca, 94.3 Mg and 1326 mg/L K. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 76
页数:5
相关论文
共 50 条
  • [31] Freezing enhances the phytocompound content in cornelian cherry (Cornus mas L.) liqueur
    Szczepaniak, Oskar
    Kobus-Cisowska, Joanna
    Kmiecik, Dominik
    CZECH JOURNAL OF FOOD SCIENCES, 2020, 38 (04) : 259 - 263
  • [32] CORNELIAN CHERRY (Cornus mas L.) JUICES AS A SOURCE OF MINERALS IN HUMAN DIET
    Krosniak, M.
    Gastol, M.
    Szalkowski, M.
    Zagrodzki, P.
    Derwisz, M.
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2010, 73 (17-18): : 1155 - 1158
  • [33] Pomological studies of Bulgarian cultivars and forms of cornelian cherry (Cornus mas L.)
    Zhivondov, A.
    Malchev, S.
    Pandova, S.
    III INTERNATIONAL SYMPOSIUM ON HORTICULTURAL CROP WILD RELATIVES, 2019, 1259 : 55 - 60
  • [34] Determination of Inorganic Elements in Chicken Muscle by Sealed Microwave Digestion ICP-AES
    Sun Tao
    Long Dan-feng
    Xin Guo-sheng
    Liu Zhi-yun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (07) : 1965 - 1967
  • [35] Study of the elements determination method in animal fur by microwave digestion ICP-AES
    Hou Tian-ping
    Wang Song-jun
    Cao Lin
    Chang Ping
    Hou Yue
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (08) : 1933 - 1937
  • [36] Study of the elements determination method in animal fur by microwave digestion ICP-AES
    Hou, Tian-Ping
    Wang, Song-Jun
    Cao, Lin
    Chang, Ping
    Hou, Yue
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2008, 28 (08): : 1933 - 1937
  • [37] Genetic diversity in fruit quality traits in cornelian cherry (Cornus mas L.)
    Ercisli, S
    Orhan, E
    Esitken, A
    ASIAN JOURNAL OF CHEMISTRY, 2006, 18 (01) : 650 - 654
  • [38] Experimental investigation of drying characteristics of cornelian cherry fruits (Cornus mas L.)
    Ozgen, Filiz
    HEAT AND MASS TRANSFER, 2015, 51 (03) : 343 - 352
  • [39] Some nutritional, pomological and physical properties of cornelian cherry (Cornus mas L.)
    Demir, F
    Kalyoncu, IH
    JOURNAL OF FOOD ENGINEERING, 2003, 60 (03) : 335 - 341
  • [40] Determination of metal elements in Mongolian medicine Chagederi by ICP-AES with microwave digestion
    Er-Deng Sang
    Bao Yind-Lai
    Si Qin-Ba-Te-Er
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (04) : 940 - 942