Evaluation of fit for 3D-printed retainers compared with thermoform retainers

被引:53
|
作者
Cole, David [1 ]
Bencharit, Sompop [2 ,3 ]
Carrico, Caroline K. [4 ]
Arias, Andrew [5 ]
Tufekci, Eser [1 ]
机构
[1] Virginia Commonwealth Univ, Sch Dent, Dept Orthodont, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Sch Dent, Dept Gen Practice, Richmond, VA 23298 USA
[3] Virginia Commonwealth Univ, Coll Engn, Dept Biomed Engn, Richmond, VA 23298 USA
[4] Virginia Commonwealth Univ, Oral Hlth Res Core, Oral Hlth Promot & Community Outreach, Richmond, VA 23298 USA
[5] Virginia Commonwealth Univ, Sch Dent, Richmond, VA 23298 USA
关键词
DIAGNOSTIC-ACCURACY; MODELS; TRUENESS;
D O I
10.1016/j.ajodo.2018.09.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: In the literature, there is little information available on 3D-printed orthodontic retainers. This study examined the accuracy of 3D-printed retainers compared with conventional vacuum-formed and commercially available vacuum-formed retainers. Methods: Three reference models (models 1, 2, and 3) were used to fabricate traditional vacuum-formed, commercially available vacuum-formed, and 3D-printed retainers. For each model, retainers were made using the 3 methods (a total of 27 retainers). To determine the trueness, ie, closeness of a model to a true model, the distance between the retainer and its digital model at reference points were calculated with the use of engineering software. The measurements were reported as average absolute observed values and compared with those of the conventional vacuum-formed retainers. Results: Average differences of the conventional vacuum-formed retainers ranged from 0.10 to 0.20 mm. The commercially available and 3D-printed retainers had ranges of 0.10 to 0.30 mm and 0.10 to 0.40 mm, respectively. Conclusions: The conventional vacuum-formed retainers showed the least amount of deviation from the original reference models and the 3D-printed retainers showed the greatest deviation. However, all 3 methods yielded measurements within 0.5 mm, which has previously been accepted to be clinically sufficient.
引用
收藏
页码:592 / 599
页数:8
相关论文
共 50 条
  • [21] T-Scan Novus System Application-Digital Occlusion Analysis of 3D Printed Orthodontics Retainers
    Shopova, Dobromira
    Yaneva, Antoniya
    Bakova, Desislava
    Mihaylova, Anna
    Yordanova, Miroslava
    Yordanova, Svetlana
    APPLIED SCIENCES-BASEL, 2023, 13 (14):
  • [22] The influence of 3-dimensional printing layer thickness on model accuracy and the perceived fit of thermoformed retainers
    Elshebiny, Tarek
    Canepa, Ian
    Kasper, F. Kurtis
    Tsolakis, Ioannis A.
    Matthaios, Stefanos
    Palomo, Juan Martin
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2025, 167 (04)
  • [23] Evaluation of the precision of operative augmented reality compared to standard neuronavigation using a 3D-printed skull
    Haemmerli, Julien
    Davidovic, Alioucha
    Meling, Torstein R.
    Chavaz, Lara
    Schaller, Karl
    Bijlenga, Philippe
    NEUROSURGICAL FOCUS, 2021, 50 (01) : 1 - 8
  • [24] 3D-printed minimalists
    Gross, Heinz
    Gross, Sebastian
    Nobrega, Miguel J.
    Vidal, Joao P.O.
    Kunststoffe International, 2019, 109 (1-2): : 40 - 43
  • [25] A 3D-Printed Computer
    Shirmohammadli, Vahideh
    Bahreyni, Behraad
    ADVANCED INTELLIGENT SYSTEMS, 2023, 5 (08)
  • [26] 3D-Printed Microfluidics
    Au, Anthony K.
    Huynh, Wilson
    Horowitz, Lisa F.
    Folch, Albert
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (12) : 3862 - 3881
  • [27] 3D-printed microboat
    不详
    NATURE, 2020, 587 (7835) : 527 - 527
  • [28] 3D-PRINTED THERMOPLASTICS
    不详
    ADVANCED MATERIALS & PROCESSES, 2021, 179 (04): : 9 - 9
  • [29] 3D-printed ceramics
    Button, Keith (buttonkeith@gmail.com), 1600, AIAA International (58):
  • [30] Comparative evaluation of the accuracy of 3D-printed denture teeth
    Alalawi, Haidar
    Al-Qarni, Faisal D.
    Gad, Mohammed M.
    SAUDI DENTAL JOURNAL, 2023, 35 (04) : 365 - 371