Evaluation of fit for 3D-printed retainers compared with thermoform retainers

被引:53
|
作者
Cole, David [1 ]
Bencharit, Sompop [2 ,3 ]
Carrico, Caroline K. [4 ]
Arias, Andrew [5 ]
Tufekci, Eser [1 ]
机构
[1] Virginia Commonwealth Univ, Sch Dent, Dept Orthodont, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Sch Dent, Dept Gen Practice, Richmond, VA 23298 USA
[3] Virginia Commonwealth Univ, Coll Engn, Dept Biomed Engn, Richmond, VA 23298 USA
[4] Virginia Commonwealth Univ, Oral Hlth Res Core, Oral Hlth Promot & Community Outreach, Richmond, VA 23298 USA
[5] Virginia Commonwealth Univ, Sch Dent, Richmond, VA 23298 USA
关键词
DIAGNOSTIC-ACCURACY; MODELS; TRUENESS;
D O I
10.1016/j.ajodo.2018.09.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: In the literature, there is little information available on 3D-printed orthodontic retainers. This study examined the accuracy of 3D-printed retainers compared with conventional vacuum-formed and commercially available vacuum-formed retainers. Methods: Three reference models (models 1, 2, and 3) were used to fabricate traditional vacuum-formed, commercially available vacuum-formed, and 3D-printed retainers. For each model, retainers were made using the 3 methods (a total of 27 retainers). To determine the trueness, ie, closeness of a model to a true model, the distance between the retainer and its digital model at reference points were calculated with the use of engineering software. The measurements were reported as average absolute observed values and compared with those of the conventional vacuum-formed retainers. Results: Average differences of the conventional vacuum-formed retainers ranged from 0.10 to 0.20 mm. The commercially available and 3D-printed retainers had ranges of 0.10 to 0.30 mm and 0.10 to 0.40 mm, respectively. Conclusions: The conventional vacuum-formed retainers showed the least amount of deviation from the original reference models and the 3D-printed retainers showed the greatest deviation. However, all 3 methods yielded measurements within 0.5 mm, which has previously been accepted to be clinically sufficient.
引用
收藏
页码:592 / 599
页数:8
相关论文
共 50 条
  • [1] Direct 3D-Printed Orthodontic Retainers. A Systematic Review
    Tsoukala, Efthimia
    Lyros, Ioannis
    Tsolakis, Apostolos I.
    Maroulakos, Michael P.
    Tsolakis, Ioannis A.
    CHILDREN-BASEL, 2023, 10 (04):
  • [2] Effect of print angulation on the accuracy and precision of 3D-printed orthodontic retainers
    Williams, Allison
    Bencharit, Sompop
    Yang, Il-Hyung
    Stilianoudakis, Spiro Christos
    Carrico, Caroline K.
    Tufekci, Eser
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (01) : 133 - 139
  • [3] 3D-Printed Wearable Personalized Orthodontic Retainers for Sustained Release of Clonidine Hydrochloride
    Jiang, Heliu
    Fu, Junhui
    Li, Mingguang
    Wang, Shanshan
    Zhuang, Bo
    Sun, Haiyan
    Ge, Cheng
    Feng, Bin
    Jin, Yiguang
    AAPS PHARMSCITECH, 2019, 20 (07)
  • [4] 3D-Printed Wearable Personalized Orthodontic Retainers for Sustained Release of Clonidine Hydrochloride
    Heliu Jiang
    Junhui Fu
    Mingguang Li
    Shanshan Wang
    Bo Zhuang
    Haiyan Sun
    Cheng Ge
    Bin Feng
    Yiguang Jin
    AAPS PharmSciTech, 20
  • [5] Mechanical Properties of 3D Printed Orthodontic Retainers
    Firlej, Marcel
    Zaborowicz, Katarzyna
    Zaborowicz, Maciej
    Firlej, Ewa
    Domagala, Ivo
    Pieniak, Daniel
    Igielska-Kalwat, Joanna
    Dmowski, Artur
    Biedziak, Barbara
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (09)
  • [6] Optical properties of 3D printed orthodontic retainers
    Uzunov, T.
    Yordanova-Ignatova, T.
    Grozdanova-Uzunova, R.
    Stoyanova, N.
    Stoev, Y.
    Apostolov, N.
    Taneva, I.
    Bogdanov, V.
    XXII INTERNATIONAL CONFERENCE AND SCHOOL ON QUANTUM ELECTRONICS, ICSQE 2022, 2023, 2487
  • [7] Effect of post-processing on the surface, optical, mechanical, and dimensional properties of 3D-printed orthodontic clear retainers
    Neoh, Siew Peng
    Khantachawana, Anak
    Santiwong, Peerapong
    Chintavalakorn, Rochaya
    Srikhirin, Toemsak
    CLINICAL ORAL INVESTIGATIONS, 2025, 29 (01)
  • [8] 3D designed and manufactured retainers
    Tee, Selena H. M.
    Glockengiesser, Joerg
    Knode, Vanessa
    Fleming, Padhraig S.
    SEMINARS IN ORTHODONTICS, 2025, 31 (01) : 167 - 176
  • [9] Anterior California Bridges: Marginal fit evaluation of inlay-retainers.
    Mason, PN
    Ferrari, M
    Calabrese, M
    Graiff, L
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1229 - 1229
  • [10] Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts
    Abualsaud, Reem
    Alalawi, Haidar
    DENTISTRY JOURNAL, 2022, 10 (11)