Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus

被引:107
|
作者
Matassi, Fabrizio [1 ]
Angeloni, Renzo [2 ]
Carulli, Christian [1 ]
Civinini, Roberto [1 ]
Di Bella, Leonardo [2 ]
Redl, Birgit [1 ]
Innocenti, Massimo [1 ]
机构
[1] Univ Florence, Dept Special Surg Sci, Orthoped Clin 1, I-50139 Florence, Italy
[2] Azienda Osped Careggi, Gen Orthoped Unit 3, I-50139 Florence, Italy
关键词
Proximal humeral fracture; Fibular allograft; Locking plate; Medial support; Endosteal implant; INTERNAL-FIXATION; MEDIAL SUPPORT; OPEN REDUCTION; LOCKED PLATE; COMPLICATIONS; GRAFT;
D O I
10.1016/j.injury.2012.08.004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The use of an intramedullary fibular allograft together with a locking plate fixation has been recently described in biomechanical studies to provide additional medial support and prevent varus malalignment for displaced proximal humeral fractures with promising results. The aim of this study was to evaluate the clinical and radiographic outcome of a locking plate with fibular allograft augmentation in unstable humeral fractures. Methods: We prospectively assessed the functional outcome and complications in 17 patients with proximal humeral fractures with disrupted medial column, treated with a locking plate and a fibular strut graft. The median patient age was 62 years. Postoperative assessments included radiographic imaging, range of motion, pain according to the visual analogue scale (VAS), Short Form (SF36) Health Survey, Constant-Murley and Disabilities of the Arm, Shoulder and Hand (DASH) shoulder scores as well as return to previous occupation and complications. Results: No patients were lost to follow-up and no major complications were recorded. There was no collapse of the humeral head more than 2 mm, osteonecrosis or screw penetration of the articular surface. All fractures healed clinically and radiographically. After an average follow-up of 13 months, the mean Constant score was 79 points. The mean active flexion was 149 degrees; extension, 47 degrees; internal rotation, 40 degrees; external rotation, 65 degrees; and abduction, 135 degrees. The median VAS pain level was 1 point. The median DASH score was 33 points, and the median SF36 was 83 points. Conclusion: Locking plate with fibular graft augmentation is a safe and promising technique to support the humeral head and maintain reduction in the proximal humeral fracture with medial comminution. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1939 / 1942
页数:4
相关论文
共 50 条
  • [21] Allograft augmentation in proximal humerus fractures; [Allograft-Augmentation bei proximalen Humerusfrakturen]
    Euler S.A.
    Kralinger F.S.
    Hengg C.
    Wambacher M.
    Blauth M.
    Operative Orthopädie und Traumatologie, 2016, 28 (3) : 153 - 163
  • [22] The potential of locking plate with intramedullary fibular allograft to manage proximal humeral fracture with an unstable medial column
    Young-Kyu Kim
    Suk-Woong Kang
    Kyu-Hak Jung
    Young-Kwang Oh
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 91 - 97
  • [23] The potential of locking plate with intramedullary fibular allograft to manage proximal humeral fracture with an unstable medial column
    Kim, Young-Kyu
    Kang, Suk-Woong
    Jung, Kyu-Hak
    Oh, Young-Kwang
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (01) : 91 - 97
  • [24] A Prospective Clinical Study of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate
    Yang, Huiguang
    Li, Zhongze
    Zhou, Feng
    Wang, Daoyuan
    Zhong, Baoliang
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (01) : 11 - 17
  • [25] Locking Plate Combined With Endosteal Fibular Allograft Augmentation for Medial Column Comminuted Proximal Humeral Fracture
    Tuerxun, Maimaitiaili
    Tuxun, Aikebaier
    Zeng, Langqing
    Wang, Qiuke
    Chen, Yunfeng
    ORTHOPEDICS, 2020, 43 (06) : 367 - 372
  • [26] A Prospective Clinical Study of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate
    Bali, Kamal
    Krishnan, Vibhu
    Aggarwal, Sameer
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (04) : E42 - E42
  • [27] Efficacy of fibular allograft and locking plate in the treatment of proximal humeral fracture
    Li, Dezhi
    Chen, Shengwen
    Mao, Jun
    Deng, Ting
    ASIAN JOURNAL OF SURGERY, 2023, 46 (03) : 1372 - 1373
  • [28] Complications after Locking Plate Fixation of Fractures of the Proximal Humerus
    Gerber, Christian
    Spross, Christian
    Gren, Holger
    Jost, Bernhard
    SWISS MEDICAL WEEKLY, 2011, 141 : 29S - 29S
  • [29] Current concepts in locking plate fixation of proximal humerus fractures
    Christoph J. Laux
    Florian Grubhofer
    Clément M. L. Werner
    Hans-Peter Simmen
    Georg Osterhoff
    Journal of Orthopaedic Surgery and Research, 12
  • [30] Functional Outcome and Complications in Management of Proximal Humerus Fractures Operated with Proximal Humerus Locking Plate
    George, P. K.
    Dasgupta, B.
    Bhaladhare, S. M.
    Reddy, B. P., V
    Jain, A.
    Jogani, A. D.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (02) : 47 - 54