Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus

被引:107
|
作者
Matassi, Fabrizio [1 ]
Angeloni, Renzo [2 ]
Carulli, Christian [1 ]
Civinini, Roberto [1 ]
Di Bella, Leonardo [2 ]
Redl, Birgit [1 ]
Innocenti, Massimo [1 ]
机构
[1] Univ Florence, Dept Special Surg Sci, Orthoped Clin 1, I-50139 Florence, Italy
[2] Azienda Osped Careggi, Gen Orthoped Unit 3, I-50139 Florence, Italy
关键词
Proximal humeral fracture; Fibular allograft; Locking plate; Medial support; Endosteal implant; INTERNAL-FIXATION; MEDIAL SUPPORT; OPEN REDUCTION; LOCKED PLATE; COMPLICATIONS; GRAFT;
D O I
10.1016/j.injury.2012.08.004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The use of an intramedullary fibular allograft together with a locking plate fixation has been recently described in biomechanical studies to provide additional medial support and prevent varus malalignment for displaced proximal humeral fractures with promising results. The aim of this study was to evaluate the clinical and radiographic outcome of a locking plate with fibular allograft augmentation in unstable humeral fractures. Methods: We prospectively assessed the functional outcome and complications in 17 patients with proximal humeral fractures with disrupted medial column, treated with a locking plate and a fibular strut graft. The median patient age was 62 years. Postoperative assessments included radiographic imaging, range of motion, pain according to the visual analogue scale (VAS), Short Form (SF36) Health Survey, Constant-Murley and Disabilities of the Arm, Shoulder and Hand (DASH) shoulder scores as well as return to previous occupation and complications. Results: No patients were lost to follow-up and no major complications were recorded. There was no collapse of the humeral head more than 2 mm, osteonecrosis or screw penetration of the articular surface. All fractures healed clinically and radiographically. After an average follow-up of 13 months, the mean Constant score was 79 points. The mean active flexion was 149 degrees; extension, 47 degrees; internal rotation, 40 degrees; external rotation, 65 degrees; and abduction, 135 degrees. The median VAS pain level was 1 point. The median DASH score was 33 points, and the median SF36 was 83 points. Conclusion: Locking plate with fibular graft augmentation is a safe and promising technique to support the humeral head and maintain reduction in the proximal humeral fracture with medial comminution. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1939 / 1942
页数:4
相关论文
共 50 条
  • [1] The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus
    Bae, J. -H.
    Oh, J. -K.
    Chon, C. -S.
    Oh, C. -W.
    Hwang, J. -H.
    Yoon, Y. -C.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (07): : 937 - 941
  • [2] A new locking plate for unstable fractures of the proximal humerus
    Fankhauser, F
    Boldin, C
    Schippinger, G
    Haunschmid, C
    Szyszkowitz, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) : 176 - 181
  • [3] The Augment of the Stability in Locking Compression Plate with Intramedullary Fibular Allograft for Proximal Humerus Fractures in Elderly People
    Chen, Hua
    Yin, Peng
    Wang, Song
    Li, Jiantao
    Zhang, Lihai
    Khan, Kamran
    Zhang, Licheng
    Tang, Peifu
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [4] Clinical and radiological outcomes of unstable proximal humeral fractures treated with a locking plate and fibular strut allograft
    Panchal, Karnav
    Jeong, Jae-Jung
    Park, Sang-Eun
    Kim, Weon-Yoo
    Min, Hyung-Ki
    Kim, Ju-Yeong
    Ji, Jong-Hun
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (03) : 569 - 577
  • [5] Clinical and radiological outcomes of unstable proximal humeral fractures treated with a locking plate and fibular strut allograft
    Karnav Panchal
    Jae-Jung Jeong
    Sang-Eun Park
    Weon-Yoo Kim
    Hyung-Ki Min
    Ju-Yeong Kim
    Jong-Hun Ji
    International Orthopaedics, 2016, 40 : 569 - 577
  • [6] Outcomes of locking plate fixation with fibular allograft augmentation for proximal humeral fractures in osteoporotic patients COMPARISON WITH LOCKING PLATE FIXATION ALONE
    Lee, S. H.
    Han, S. S.
    Yoo, B. M.
    Kim, J. W.
    BONE & JOINT JOURNAL, 2019, 101B (03): : 260 - 265
  • [7] Allograft augmentation in proximal humerus fractures
    Euler, S. A.
    Kralinger, F. S.
    Hengg, C.
    Wambacher, M.
    Blauth, M.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (03): : 153 - 163
  • [8] Fibular Autograft as Medial Support with Proximal Humerus Locking Plate Construct in Comminuted Proximal Humerus Fractures: A Retrospective Analysis
    Sameer Panchal
    Sangeet Gawhale
    Amit Kumar Yadav
    Devanshu Gupta
    K. S. Akshay
    Indian Journal of Orthopaedics, 2023, 57 : 1443 - 1451
  • [9] Fibular Autograft as Medial Support with Proximal Humerus Locking Plate Construct in Comminuted Proximal Humerus Fractures: A Retrospective Analysis
    Panchal, Sameer
    Gawhale, Sangeet
    Yadav, Amit Kumar
    Gupta, Devanshu
    Akshay, K. S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (09) : 1443 - 1451
  • [10] Fibular allograft augmentation of Locking Plate Osteosynthesis for the Treatment of osteoporotic Humeral Head Fractures
    Immler, Christoph
    Gruber, Christoph
    Brunner, U. H.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2022, 17 (04): : 272 - 275