Balanced SSFP Dixon imaging with banding-artifact reduction at 3 Tesla

被引:10
|
作者
Quist, Brady [1 ,2 ]
Hargreaves, Brian A. [1 ]
Daniel, Bruce L. [1 ]
Saranathan, Manojkumar [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词
bSSFP; SSFP; fat suppression; steady-state; fat water separation; artifact reduction; STATE FREE PRECESSION; FAT-WATER SEPARATION; STEADY-STATE; MUSCULOSKELETAL MRI; MAGNETIC-RESONANCE; RELAXATION-TIMES; IN-VIVO; 3.0; T; PHASE; ACQUISITION;
D O I
10.1002/mrm.25449
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a three-dimensional (3D) balanced steady-state free-precession (bSSFP) two-point Dixon method with banding-artifact suppression to offer robust high-resolution 3D bright-fluid imaging. MethodsA complex sum reconstruction that combines phase-cycled bSSFP images acquired at specific echo times for robust fat/water separation without banding was investigated and compared with a magnitude-based method. Bloch simulations using both single-peak and multiple-peak fat models were performed to predict the performance of these methods for a wide range of echo times and repetition times. The quality and degree of fat/water separation was evaluated in both simulations and using in vivo imaging. ResultsSimulations predicted that both effective banding-artifact suppression and substantial improvements in fat/water separation are possible at echo times that are different from conventional echo times, enabling improved spatial resolution. Comparisons between various echo times and repetition times in vivo validated the improved fat/water separation and effective banding-artifact removal predicted by the simulations. ConclusionThe proposed complex sum Dixon 3D bSSFP method is able to effectively separate fat and water at different sets of echo times, while removing banding-artifacts, providing a fast, high-resolution, T-2-like sequence without blurring. Magn Reson Med 74:706-715, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:706 / 715
页数:10
相关论文
共 50 条
  • [1] Interleaved Balanced SSFP Imaging: Reduction Using Gradient Waveform Artifact Grouping
    Nielsen, Jon-Fredrik
    Nayak, Krishna S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (03) : 745 - 750
  • [2] Cardiac SSFP imaging at 3 tesla
    Schär, M
    Kozerke, S
    Fischer, SE
    Boesiger, P
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 799 - 806
  • [3] Phase-Cycled Simultaneous Multislice Balanced SSFP Imaging with CAIPIRINHA for Efficient Banding Reduction
    Wang, Yi
    Shao, Xingfeng
    Martin, Thomas
    Moeller, Steen
    Yacoub, Essa
    Wang, Danny J. J.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (06) : 1764 - 1774
  • [4] Banding-artifact reduction using an improved threshold scaling function in multitoning with stochastic screen
    Park, Tae-Yong
    Park, Kee-Hyon
    Jang, In-Su
    Kwon, Oh-Seol
    Ha, Yeong-Ho
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2007, 51 (06) : 502 - 508
  • [5] Frequency scouting for cardiac imaging with SSFP at 3 Tesla
    Wansapura, Janaka
    Fleck, Robert
    Crotty, Eric
    Gottliebson, William
    PEDIATRIC RADIOLOGY, 2006, 36 (10) : 1082 - 1085
  • [6] Frequency scouting for cardiac imaging with SSFP at 3 Tesla
    Janaka Wansapura
    Robert Fleck
    Eric Crotty
    William Gottliebson
    Pediatric Radiology, 2006, 36 : 1082 - 1085
  • [7] Dynamically Phase-Cycled Radial Balanced SSFP Imaging for Efficient Banding Removal
    Benkert, Thomas
    Ehses, Philipp
    Blaimer, Martin
    Jakob, Peter M.
    Breuer, Felix A.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 182 - 194
  • [8] Slice encoding for the reduction of outflow signal artifacts in cine balanced SSFP imaging
    Ali, Fadil
    Bydder, Mark
    Han, Hui
    Wang, Da
    Ghodrati, Vahid
    Gao, Chang
    Prosper, Ashley
    Nguyen, Kim-Lien
    Finn, J. Paul
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (04) : 2034 - 2048
  • [9] Assessment of left atrial volumes at 1.5 Tesla and 3 Tesla using FLASH and SSFP cine imaging
    Hudsmith, L. E.
    Cheng, A. S. H.
    Tyler, D. J.
    Shirodaria, C.
    Lee, J.
    Petersen, S. E.
    Francis, J. M.
    Clarke, Kieran
    Robson, M. D.
    Neubauer, S.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (04) : 673 - 679
  • [10] 50 Myocardial signal behaviors of balanced SSFP imaging at 3 T
    Kyunghyun Sung
    Krishna S Nayak
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)