Validity of a Smartphone Application in Calculating Measures of Heart Rate Variability

被引:3
|
作者
Himariotis, Andreas T. [1 ,2 ]
Coffey, Kyle F. [1 ,2 ]
Noel, Sabrina E. [1 ,3 ]
Cornell, David J. [1 ,2 ]
机构
[1] Univ Massachusetts Lowell, Hlth Assessment Lab, Lowell, MA 01854 USA
[2] Univ Massachusetts Lowell, Dept Phys Therapy & Kinesiol, Lowell, MA 01854 USA
[3] Univ Massachusetts Lowell, Dept Biomed & Nutr Sci, Lowell, MA 01854 USA
关键词
heart rate monitor; autonomic nervous system function; R-R interval data; artifact corrections; CORRELATION-COEFFICIENTS; TRAINING ADAPTATION; TIME-DOMAIN; RELIABILITY; STATISTICS; RESPONSES; HRV;
D O I
10.3390/s22249883
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The purpose of the current study was to determine the concurrent validity of the Elite HRV smartphone application when calculating heart rate variability (HRV) metrics in reference to an independent software criterion. A total of 5 minutes of R-R interval and natural log of root mean square of the successive differences (lnRMSSD) resting HRV data were simultaneously collected using two Polar H10 heart rate monitors (HRMs) in both the seated and supine positions from 22 participants (14 males, 8 females). One H10 HRM was paired with a Polar V800 watch and one with the Elite HRV application. When no artifact correction was applied, significant, but small, differences in the lnRMSSD data were observed between the software in the seated position (p = 0.022), and trivial and nonstatistically significant differences were observed in the supine position (p = 0.087). However, significant differences (p > 0.05) in the lnRMSSD data were no longer identifiable in either the seated or the supine positions when applying Very Low, Low, or Automatic artifact-correction filters. Additionally, excellent agreements (ICC3,1 = 0.938 - 0.998) and very strong to near-perfect (r = 0.889 - 0.997) relationships were observed throughout all correction levels. The Elite HRV smartphone application is a valid tool for calculating resting lnRMSSD HRV metrics.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] REPRODUCIBILITY OF HEART RATE VARIABILITY MEASURES DURING EXERCISE
    Kerrigan, D.
    Armstrong, W. J.
    Levine, S.
    Ehrman, J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S202 - S202
  • [32] Heart rate variability measures: a fresh look at reliability
    Pinna, Gian Domenico
    Maestri, Roberto
    Torunski, Antoni
    Danilowicz-Szymanowicz, Ludmilla
    Szwoch, Mallgorzata
    La Rovere, Maria Teresa
    Raczak, Grzegorz
    CLINICAL SCIENCE, 2007, 113 (3-4) : 131 - 140
  • [33] NONLINEAR MEASURES OF HEART RATE VARIABILITY AND THEIR CLINICAL SIGNIFICANCE
    Kubo, Yuyaka
    Otsuka, Kuniaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 97 : S16 - S16
  • [34] Limitations of Oximetry to Measure Heart Rate Variability Measures
    Lu, Guohua
    Yang, Fang
    CARDIOVASCULAR ENGINEERING, 2009, 9 (03) : 119 - 125
  • [35] Validity and reliability properties of canine short-term heart rate variability measures-a pilot study
    Essner, Ann
    Sjostrom, Rita
    Gustas, Pia
    Edge-Hughes, Laurie
    Zetterberg, Lena
    Hellstrom, Karin
    JOURNAL OF VETERINARY BEHAVIOR-CLINICAL APPLICATIONS AND RESEARCH, 2015, 10 (05) : 384 - 390
  • [36] Comparison of entropy rate measures for the evaluation of time series complexity: Simulations and application to heart rate and respiratory variability
    Bara, Chiara
    Pernice, Riccardo
    Catania, Cristina Angela
    Hilal, Mirvana
    Porta, Alberto
    Humeau-Heurtier, Anne
    Faes, Luca
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2024, 44 (02) : 380 - 392
  • [37] Measures of and changes in heart rate variability in pediatric heart transplant recipients
    Williams, T.
    Tang, X.
    Gilmore, G.
    Gossett, J.
    Knecht, K. R.
    PEDIATRIC TRANSPLANTATION, 2017, 21 (04)
  • [38] Reproducibility of heart rate variability measures in patients with chronic heart failure
    Ponikowski, P
    Piepoli, M
    Amadi, AA
    Chua, TP
    Harrington, D
    Volterrani, M
    Colombo, R
    Mazzuero, G
    Giordano, A
    Coats, AJS
    CLINICAL SCIENCE, 1996, 91 (04) : 391 - 398
  • [39] Outcomes prediction in heart failure by measures of heart rate variability dynamics
    Srivastava, S.
    Eleuteri, A.
    Dawson, R.
    Fisher, M.
    Elt, M.
    Laflin, R.
    Cubbon, R. M.
    Kearney, M. T.
    Fisher, A. C.
    Groves, D.
    EUROPEAN HEART JOURNAL, 2015, 36 : 1178 - 1178
  • [40] Heart Rate Variability Analysis on Reference Heart Beats and Detected Heart Beats of Smartphone Seismocardiograms
    Siecinski, Szymon
    Kostka, Pawel S.
    Tkacz, Ewaryst J.
    Piaseczna, Natalia
    Wadas, Marta
    INFORMATION TECHNOLOGY IN BIOMEDICINE, 2019, 1011 : 473 - 480