Eight years of left ventricle pacing due to inadvertent malposition of a transvenous pacemaker lead in the left ventricle

被引:17
|
作者
Vanhercke, Daniel [1 ]
Heytens, Wendy [1 ]
Verloove, Hugues [1 ]
机构
[1] AZ Sint Lucas, Dept Cardiol, BE-9000 Ghent, Belgium
来源
关键词
Left ventricle; Pacemaker; Malpositioned pacemaker lead;
D O I
10.1093/ejechocard/jen187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The inadvertent malposition of a pacemaker lead in the left ventricle is a rare and underdiagnosed pacemaker complication. A 78-year-old woman was admitted to our Emergency Department for progressive dyspnea, 8 years after transvenous pacemaker implantation. Routine 12-lead electrocardiography revealed a right bundle branch block on the paced beats, and lateral chest X-ray showed posterior deflection of the pacemaker lead, suggesting a pacemaker electrode in the left ventricle. Echocardiography confirmed that the pacing lead had migrated through the foramen ovale into the left ventricle. After review of the literature and taking into account the age and emboligenic-free history of the patient under platelet therapy, we decided to postpone the surgical removal of the malpositioned lead in the left ventricle until the need arose for cardiac surgery for additional reasons, such as valve and/or coronary illness. The general therapeutic strategy remained unchanged due to the risk of bleeding complications with anticoagulation in the patient. This case illustrates the prominent role of echocardiography in the diagnosis of unusual cardiac events.
引用
收藏
页码:825 / 827
页数:3
相关论文
共 50 条
  • [21] Lead extraction of an unintentional pacemaker lead implantation in the left ventricle from the left subclavian artery
    Strube, Camille
    Domain, Guillaume
    Dognin, Nicolas
    Dagenais, Francois
    Plourde, Benoit
    Jacques, Frederic
    Gilbert, Philippe
    Steinberg, Christian
    Philippon, Francois
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (02): : 281 - 284
  • [22] TRANSVENOUS PACEMAKER ELECTRODES PLACED UNINTENTIONALLY IN THE LEFT-VENTRICLE - 3 CASES
    WINNER, SJ
    BOON, NA
    POSTGRADUATE MEDICAL JOURNAL, 1989, 65 (760) : 98 - 102
  • [23] Pacemaker lead malposition in the left atrial roof is masked by normal pacing thresholds
    Claus Rath
    Martin Andreas
    Caesar Khazen
    Dominik Wiedemann
    Andreas Habertheuer
    Alfred Kocher
    Journal of Cardiothoracic Surgery, 9
  • [24] Pacemaker lead malposition in the left atrial roof is masked by normal pacing thresholds
    Rath, Claus
    Andreas, Martin
    Khazen, Caesar
    Wiedemann, Dominik
    Habertheuer, Andreas
    Kocher, Alfred
    JOURNAL OF CARDIOTHORACIC SURGERY, 2014, 9
  • [25] 7 YEARS OF LEFT-VENTRICULAR PACING DUE TO MALPOSITION OF PACING ELECTRODE
    SHMUELY, H
    ERDMAN, S
    STRASBERG, B
    ROSENFELD, JB
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (04): : 369 - 372
  • [26] Pacemaker electrode misplaced in the left ventricle
    Cerqueira de Almeida, Andre Luiz
    Cavalcante, Viviane Machicado
    Castro Teixeira, Marcio Diego
    Costa de Freitas, Gustavo Rocha
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2010, 95 (03) : E83 - E87
  • [27] Inadvertently placed pacemaker lead into the left ventricle without thromboembolic complication: Due to Dabigatran or chance?
    Yildiz, Ibrahim
    Yildiz, Pinar Ozmen
    KUWAIT MEDICAL JOURNAL, 2020, 52 (03): : 306 - 308
  • [28] Inadvertent malposition of a transvenous pacing lead in the left ventricleVersehentliche Fehlpositionierung einer transvenösen Schrittmacher-Elektrode im linken Ventrikel
    A. Engström
    B. Holmberg
    A. Månsson
    J. Carlsson
    Herzschrittmachertherapie & Elektrophysiologie, 2006, 17 (4): : 221 - 224
  • [29] Inadvertent left ventricular pacing due to lead malpositioning, incidentally discovered seventeen years later
    Bobat, Shahid
    How, Wei Jun
    BMJ CASE REPORTS, 2021, 14 (11)
  • [30] Monitoring biventricular pacing parameters depending on the left ventricle lead configuration
    Prochazka, Antonin
    Korpas, David
    EXPERIMENTAL & CLINICAL CARDIOLOGY, 2013, 18 (02) : 85 - 88