C1-C2 Instrumentation According to Harms/Goel in Case of Vertebral Artery below the Arch of C1: A Case Report

被引:0
|
作者
Ruf, Michael [1 ]
Drumm, Joerg [1 ]
Pitzen, Tobias [1 ]
Merk, Harry R. [2 ]
机构
[1] SRH Klinikum Karlsbad, Wirbelsaulenchirurg Orthopadie & Traumatol, Langensteinbach, Karlsbad, Germany
[2] Ernst Moritz Arndt Univ Greifswald, Klin Orthopadie, Greifswald, Germany
关键词
atlantoaxial instrumentation; vertebral artery; lateral mass screw; 1ST INTERSEGMENTAL ARTERY; COMPUTED-TOMOGRAPHY; SCREW FIXATION; ANATOMICAL VARIATIONS; POSTERIOR ARCH; FUSION; INJURY; GROOVE; ATLAS; RISK;
D O I
10.1055/s-0035-1567860
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design Case report. Background and Study Aims For stabilizing surgery of the atlantoaxial region, a precise evaluation of the course of the vertebral artery (VA) is essential to avoid vessel injury and life threatening complications. In patients with aberrant VA course, an appropriate way for fusion needs to be found. This article presents a case of an unusual VA course and illuminates the importance of surgical planning with computed tomography angiography identifying VA variations at the atlantoaxial region. Case Report A 71-year-old woman with atlantoaxial arthrosis had a VA variation (persistent first intersegmental artery). She underwent C1-C2 posterior fixation according to Harms/Goel using the typical entry points, requiring VA dissection in caudal direction. The postoperative clinical as well as radiographic result was excellent. Angiography 6 months postoperatively showed the VAs below the C1 screws with normal blood flow. Conclusions Placement of C1 screws in a patient with a persistent first intersegmental VA is possible. Careful VA dissection is the key step for safe screw placement, screw anchoring, and clinical success.
引用
收藏
页码:543 / 547
页数:5
相关论文
共 50 条
  • [21] Chronic C1-C2 Rotatory Subluxation Reduced by C1 Lateral Mass Screws and C2 Translaminar Screws: A Case Report
    Lavelle, William F.
    Palomino, Kathryn
    Badve, Siddharth A.
    Albanese, Stephen A.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2017, 37 (03) : E174 - E177
  • [22] Importance of C1 pedicle screws in the Goel-Harms technique
    Kobbe, Philipp
    Kandziora, Frank
    Hildebrand, Frank
    Scholz, Matti
    UNFALLCHIRURG, 2017, 120 (12): : 1096 - 1096
  • [23] Application of the Harms Technique to Treat Undiagnosed Intractable C1-C2 Unilateral Neck Pain: A Case Report
    Bhatti, Adnan Bashir
    Kim, Sunny
    CUREUS, 2016, 8 (09):
  • [24] Dorsale Stabilisation der Halswirbelkörper HWK1/HWK2 modifiziert nach Goel-Harms mit HWK-1-PedikelschraubenDorsal stabilization of C1/C2 modified according to Goel-Harms with C1 pedicle screws
    Lennart Viezens
    Stephan Sehmisch
    Lukas Weiser
    Marc Dreimann
    Wolfgang Lehmann
    Operative Orthopädie und Traumatologie, 2019, 31 (4) : 275 - 283
  • [25] Vertebral artery in relationship to C1-C2 vertebrae: An anatomical study
    Cacciola, F
    Phalke, U
    Goel, A
    NEUROLOGY INDIA, 2004, 52 (02) : 178 - 184
  • [26] Bedeutung der C1-Pedikelschraube bei der Goel-Harms-TechnikImportance of C1 pedicle screws in the Goel-Harms technique
    Philipp Kobbe
    Frank Kandziora
    Frank Hildebrand
    Matti Scholz
    Der Unfallchirurg, 2017, 120 (12): : 1096 - 1096
  • [27] PHRENIC STIMULATION OF C1-C2 TETRAPLEGIA - A CASE-REPORT
    ORDRONNEAU, J
    DESPINS, P
    KERAVEL, Y
    CHAILLEUX, E
    GUIHENEUC, P
    CHOLLET, S
    REVUE DES MALADIES RESPIRATOIRES, 1989, 6 (05) : 469 - 471
  • [28] CONGENITAL ABSENCE OF THE C1 VERTEBRAL ARCH
    MACE, SE
    HOLLIDAY, R
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1986, 4 (04): : 326 - 329
  • [29] A giant spinal schwannoma at the C1-C2 level: A case report
    Wu, Xiaodong
    Li, Dazhi
    Zhang, Lu
    Li, Yanming
    MEDICINE, 2025, 104 (01)
  • [30] Biomechanical Comparison of a Novel C1 Posterior Locking Plate With the Harms Technique in A C1-C2 Fixation Model
    Kelly, Brian P.
    Glaser, John A.
    DiAngelo, Denis J.
    SPINE, 2008, 33 (24) : E920 - E925