Full Versus Surface Tibial Baseplate Cementation in Total Knee Arthroplasty

被引:20
|
作者
Galasso, Olimpio [1 ]
Jenny, Jean-Yves [2 ]
Saragaglia, Dominique [3 ]
Miehlke, Rolf K. [4 ]
机构
[1] Magna Graecia Univ Catanzaro, Dept Orthopaed & Trauma Surg, Catanzaro, Italy
[2] Univ Hosp Strasbourg, Ctr Orthoped & Hand Surg, Strasbourg, France
[3] Univ Hosp Grenoble, Dept Orthopaed Surg & Sport Traumatol, Echirolles, France
[4] Rhine Main Ctr Joint Dis, Div Knee Replacement, Wiesbaden, Germany
关键词
CEMENTING TECHNIQUES; COMPONENT FIXATION; REPLACEMENT; PROSTHESES; SYSTEM; STEM;
D O I
10.3928/01477447-20130122-16
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The use of a keel in the tibial component during modern primary total knee arthroplasty (TKA) has become common, and its cementation may affect the future performance of the prosthesis. Although proponents of cementing the entire tibial component argue that this technique provides better initial fixation and may prevent aseptic loosening, reasons exist to apply cement only to the tibial baseplate. In this study, 232 patients who underwent TKA using full or surface cementation of the tibial baseplate were evaluated at an average 5.6-year follow-up to assess survivorship and clinical results. The cumulative survival rate at 8 years was 97.1%. With revision of either component for any reason considered the endpoint, no significant difference was noted between full and surface cemented groups. Knee Society Score, range of motion, and femorotibial mechanical angle significantly increased postoperatively. Multivariate analysis revealed that good preoperative range of motion and Knee Society Scores were related to good postoperative range of motion and Knee Society Scores. Follow-up length was a negative predictor of postoperative Knee Society Score. The use of full or surface cementation of the baseplate was unrelated to the postoperative clinical outcomes. Clinical outcomes did not differ according to the tibial component cementation technique. The results of this study suggest that cementing the keel of the tibial component during primary TKA has no advantage for patients. Longer-term follow-up and proper patient randomization are required to confirm these findings.
引用
收藏
页码:E151 / E158
页数:8
相关论文
共 50 条
  • [31] Contemporary Cruciate-Retaining Total Knee Arthroplasty with a Pegged Tibial Baseplate Results at a Minimum of Ten Years
    Barrington, John W.
    Sah, Alexander
    Malchau, Henrik
    Burke, Dennis W.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (04): : 874 - 878
  • [32] Dissociation of the polyethylene insert from the tibial baseplate after total knee arthroplasty: a case report and review of the literature
    Wiley, Marcel R.
    Huo, Michael H.
    CURRENT ORTHOPAEDIC PRACTICE, 2018, 29 (02): : 180 - 183
  • [33] Survival of total knee arthroplasty after high tibial osteotomy versus primary total knee arthroplasty A meta-analysis
    Seo, Seung-Suk
    Nha, Kyung-Wook
    Kim, Tae-Yeong
    Shin, Young-Soo
    MEDICINE, 2019, 98 (30) : e16609
  • [34] In vivo kinematics of total knee arthroplasty -: Concave versus posterior-stabilised tibial joint surface
    Uvehammer, J
    Kärrholm, J
    Brandsson, S
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (04): : 499 - 505
  • [35] Polyethylene wear on the distal tibial insert surface in total knee arthroplasty
    Gabriel, SM
    Dennis, DA
    Honey, MJ
    Scott, RD
    KNEE, 1998, 5 (03): : 221 - 228
  • [36] Osteolysis after total knee arthroplasty: Influence of tibial baseplate surface finish and sterilization of polyethylene insert - Findings at five to ten years postoperatively
    Collier, MB
    Engh, CA
    McAuley, JP
    Ginn, SD
    Engh, GA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (12): : 2702 - 2708
  • [37] Tibial baseplate positioning in robotic-assisted and conventional unicompartmental knee arthroplasty
    MacCallum K.P.
    Danoff J.R.
    Geller J.A.
    European Journal of Orthopaedic Surgery & Traumatology, 2016, 26 (1) : 93 - 98
  • [38] COMPUTATIONAL ANALYSIS OF CEMENTATION TECHNIQUES FOR TOTAL KNEE ARTHROPLASTY
    Kelly, Nicola
    Cawley, Derek
    Shannon, Fintan J.
    McGarry, Patrick J.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 639 - 640
  • [39] Tibial component fixation with cement - Full-versus surface-cementation techniques
    Peters, CL
    Craig, MA
    Mohr, RA
    Bachus, KN
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (409) : 158 - 168
  • [40] Radiolucent lines and revision risk in total knee arthroplasty using the conventional versus the Attune S plus tibial baseplate RESULTS OF A MULTICENTRE OBSERVATIONAL STUDY
    Smolle, M. A.
    Keintzel, M.
    Staats, K.
    Boehler, C.
    Windhager, R.
    Koutp, A.
    Leithner, A.
    Donner, S.
    Reiner, T.
    Renkawitz, T.
    Sava, M-P
    Hirschmann, M. T.
    Sadoghi, P.
    BONE & JOINT JOURNAL, 2024, 106B (11): : 1240 - 1248