Automated assay of the potency of natural antioxidants using pipetting robot and spectrophotometry

被引:23
|
作者
Pohanka, Miroslav [2 ]
Sochor, Jiri [1 ,3 ]
Ruttkay-Nedecky, Branislav [1 ,3 ]
Cernei, Natalia [1 ,3 ]
Adam, Vojtech [1 ,3 ]
Hubalek, Jaromir [1 ,3 ]
Stiborova, Marie [4 ]
Eckschlager, Tomas [5 ]
Kizek, Rene [1 ,3 ]
机构
[1] Mendel Univ Brno, Fac Agron, Dept Chem & Biochem, Brno 61300, Czech Republic
[2] Univ Def, Fac Mil Hlth Sci, Hradec Kralove, Czech Republic
[3] Brno Univ Technol, Cent European Inst Technol, Brno, Czech Republic
[4] Charles Univ Prague, Fac Sci, Dept Biochem, Prague, Czech Republic
[5] Charles Univ Prague, Fac Med 2, Dept Paediat Haematol & Oncol, Prague, Czech Republic
关键词
DPPH; FRAP; ABTS; DMPD; free radicals; antioxidant; POWER FRAP; ACID;
D O I
10.2478/v10136-012-0006-y
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
In the food industry, in the process of creating new agricultural plant products, and in the testing of anti-cancer drugs there is often a need to assay multiple samples of low molecular weight antioxidants, plant samples and foods rich in antioxidants, with minimal additional costs and low degrees of uncertainty. With these demands in mind, we decided to study the fully automated assay of antioxidants using not only automated sample measurements but also automated processing of samples and application of reagents. The automated pipetting system epMotion 5075 and the automated spectrophotometer BS 400 were chosen for the assay purposes. Five methods were introduced for the automation: 2-diphenyl-1-picrylhydrazyl (DPPH) test, ferric reducing antioxidant power (FRAP) method, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid (ABTS) based test, N,N-dimethyl-1,4-diaminobenzene (DMPD) based test and the free radicals method. Samples containing one of the four antioxidants (standard rutin, quercitrin, ferulic and gallic acid) in a range 1-1000 mu g/ml were used throughout. All of the tested methods were found suitable for implementation in an automated assay. However, some of them, such as the ABTS test failed to assay all tested antioxidants. The coefficients of determination were also unequal. From the analytical point of view, FRAP methods provided the most reliable results in the automated assay; because of the capacity of the method, approximately 240 samples per hour (one sample per 15 seconds) can be assayed using the automated protocol. We were encouraged by the data received and we expect further interest in the practical performance of such automation. As a mean of testing the robustness of our method, in the next step of our study, oxidative status was assessed in model cell lines derived from prostate cancer (PC-3, PNT1A and 22RV1) that were cultured on ellipticine (0, 0.5, 1, 1.5, 2, 2.5, 5, 7.5, 10, 15 mu mol/l) supplemented agar. Antioxidant activity was assessed (DPPH, ABTS, FRAP, DMPD, FR) and calculated on the phenolic antioxidant level (rutin, quercitrin, ferulic and gallic acid), and thus an estimation was formulated of the oxidative stress as a result of the impact of anti-cancer drugs. It can be demonstrated that the new method has wide applicability.
引用
收藏
页码:155 / 167
页数:13
相关论文
共 50 条
  • [21] Assessment of an in vitro potency assay for evaluation of immune cell-mediated cytotoxicity using the Omni Pro 12 automated imaging platform
    Sullivan, Denise
    Stemkens, Lieke
    Thijssen, Inge
    Meiler, Svenja
    Califano, Danielle
    Chvatal, Stacie
    Millard, Daniel
    CANCER RESEARCH, 2024, 84 (06)
  • [22] Inhibin A measurement using an automated assay platform
    Lambert-Messerlian, G. M.
    Palomaki, G. E.
    Canick, J. A.
    PRENATAL DIAGNOSIS, 2008, 28 (05) : 399 - 403
  • [23] Automated microalbumin assay using the Abbott spectrum
    Fleming, N
    LABORATORY MEDICINE, 1996, 27 (05) : 339 - 341
  • [24] Evaluation of the Ph. Eur. anti-A and anti-B assay on a pipetting robot in combination with a camera guided reading mode
    Hausammann, G. J.
    Bellac, C. L.
    Sanger, M.
    Gilgen, M.
    BIOLOGICALS, 2017, 47 : 76 - 80
  • [25] TUBERCULIN POTENCY ASSAY USING 2 PARALLEL DOSE RESPONSE LINES
    HATAKEYA.H
    JAPANESE JOURNAL OF VETERINARY SCIENCE, 1969, S 31 : 35 - &
  • [26] Potency testing of Clostridium perfringens vaccines using cell culture assay
    Borrmann, E
    Schulze, F
    Diller, R
    TIERARZTLICHE UMSCHAU, 1997, 52 (10): : 616 - 621
  • [27] Development of homogeneous plasmonic potency assay using gold nanoparticle immunocomplexes
    Han, Jin-Hee
    Li, Fang
    Gunawan, Rico C.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 181
  • [28] Human potency predictions for aldehydes using the local lymph node assay
    Basketter, DA
    Wright, ZM
    Warbrick, EV
    Dearman, RJ
    Kimber, I
    Ryan, CA
    Gerberick, GF
    White, IR
    CONTACT DERMATITIS, 2001, 45 (02) : 89 - 94
  • [29] COMPARISON OF POTENCY ESTIMATES FOR GLUCOCORTICOIDS USING 2 THYMOLYTIC ASSAY PROCEDURES
    MAUER, SI
    HEYDER, E
    RINGLER, I
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1962, 111 (02): : 345 - &
  • [30] Low-cost automated pipetting system using a single board computer and 3D-printing
    Boppana, Naga P. D.
    Snow, Robyn A.
    Simone, Paul S.
    Emmert, Gary L.
    Brown, Michael A.
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2023, 51 (04) : 355 - 370