Automated assay of the potency of natural antioxidants using pipetting robot and spectrophotometry

被引:23
|
作者
Pohanka, Miroslav [2 ]
Sochor, Jiri [1 ,3 ]
Ruttkay-Nedecky, Branislav [1 ,3 ]
Cernei, Natalia [1 ,3 ]
Adam, Vojtech [1 ,3 ]
Hubalek, Jaromir [1 ,3 ]
Stiborova, Marie [4 ]
Eckschlager, Tomas [5 ]
Kizek, Rene [1 ,3 ]
机构
[1] Mendel Univ Brno, Fac Agron, Dept Chem & Biochem, Brno 61300, Czech Republic
[2] Univ Def, Fac Mil Hlth Sci, Hradec Kralove, Czech Republic
[3] Brno Univ Technol, Cent European Inst Technol, Brno, Czech Republic
[4] Charles Univ Prague, Fac Sci, Dept Biochem, Prague, Czech Republic
[5] Charles Univ Prague, Fac Med 2, Dept Paediat Haematol & Oncol, Prague, Czech Republic
关键词
DPPH; FRAP; ABTS; DMPD; free radicals; antioxidant; POWER FRAP; ACID;
D O I
10.2478/v10136-012-0006-y
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
In the food industry, in the process of creating new agricultural plant products, and in the testing of anti-cancer drugs there is often a need to assay multiple samples of low molecular weight antioxidants, plant samples and foods rich in antioxidants, with minimal additional costs and low degrees of uncertainty. With these demands in mind, we decided to study the fully automated assay of antioxidants using not only automated sample measurements but also automated processing of samples and application of reagents. The automated pipetting system epMotion 5075 and the automated spectrophotometer BS 400 were chosen for the assay purposes. Five methods were introduced for the automation: 2-diphenyl-1-picrylhydrazyl (DPPH) test, ferric reducing antioxidant power (FRAP) method, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid (ABTS) based test, N,N-dimethyl-1,4-diaminobenzene (DMPD) based test and the free radicals method. Samples containing one of the four antioxidants (standard rutin, quercitrin, ferulic and gallic acid) in a range 1-1000 mu g/ml were used throughout. All of the tested methods were found suitable for implementation in an automated assay. However, some of them, such as the ABTS test failed to assay all tested antioxidants. The coefficients of determination were also unequal. From the analytical point of view, FRAP methods provided the most reliable results in the automated assay; because of the capacity of the method, approximately 240 samples per hour (one sample per 15 seconds) can be assayed using the automated protocol. We were encouraged by the data received and we expect further interest in the practical performance of such automation. As a mean of testing the robustness of our method, in the next step of our study, oxidative status was assessed in model cell lines derived from prostate cancer (PC-3, PNT1A and 22RV1) that were cultured on ellipticine (0, 0.5, 1, 1.5, 2, 2.5, 5, 7.5, 10, 15 mu mol/l) supplemented agar. Antioxidant activity was assessed (DPPH, ABTS, FRAP, DMPD, FR) and calculated on the phenolic antioxidant level (rutin, quercitrin, ferulic and gallic acid), and thus an estimation was formulated of the oxidative stress as a result of the impact of anti-cancer drugs. It can be demonstrated that the new method has wide applicability.
引用
收藏
页码:155 / 167
页数:13
相关论文
共 50 条
  • [1] ASSAY OF NATURAL ANTIOXIDANTS POTENCY USING PIPETING ROBOT AND SPEKTROPHOTOMETRY
    Dobes, J.
    Sochor, J.
    Ruttkay-Nedecky, B.
    Adam, V
    Kizek, R.
    Klejdus, B.
    MENDELNET 2012, 2012, : 1166 - 1173
  • [2] ADAPTATIONS TO KEEP A THYROTROPIN IMMUNORADIOMETRIC ASSAY SUPERSENSITIVE WITH AUTOMATED PIPETTING
    SURMONT, DWA
    ALEXANDRE, JA
    CLINICAL CHEMISTRY, 1988, 34 (02) : 370 - 371
  • [3] Automated compound formatting using a pipetting station
    Spaan, R
    Loughlin, J
    AMERICAN LABORATORY, 2000, 32 (14) : 42 - +
  • [4] Automated pipetting robot for proxy high-throughput viscometry of Newtonian fluids
    Soh, Beatrice W.
    Chitre, Aniket
    Lee, Wen Yang
    Bash, Daniil
    Kumar, Jatin N.
    Hippalgaonkar, Kedar
    DIGITAL DISCOVERY, 2023, 2 (02): : 481 - 488
  • [5] AUTOMATED METHODS FOR THE ASSAY OF NATURAL TOXINS USING ROBOTICS
    CARMAN, AS
    KUAN, SS
    FRANCIS, OJ
    KIRSCHENHEUTER, GP
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1987, 64 (05) : 624 - 624
  • [6] High-Throughput Bacteriophage Testing with Potency Determination: Validation of an Automated Pipetting and Phage Drop-Off Method
    Dufour, Nicolas
    Delattre, Raphaelle
    Debarbieux, Laurent
    BIOMEDICINES, 2024, 12 (02)
  • [7] Automated Preparation of MS-Sensitive Fluorescently Labeled N-Glycans with a Commercial Pipetting Robot
    Reed, Corey E.
    Fournier, Jennifer
    Vamvoukas, Nikolaos
    Koza, Stephan M.
    SLAS TECHNOLOGY, 2018, 23 (06): : 550 - 559
  • [8] ASSAY FOR AMOXICILLIN IN URINE USING DERIVATIVE SPECTROPHOTOMETRY
    ELWALILY, AM
    ELSAYED, MAH
    KORANY, MA
    GALAL, SM
    JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 1992, 17 (02) : 101 - 105
  • [9] Validation of an automated chromogenic assay of potency of factor VIII in commercial concentrates
    Collazo, V.
    Alonso, C.
    Frutos, G.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 (01) : 38 - 45
  • [10] AUTOMATED PRINTING PROCESS USING A ROBOT
    Menakadevi, T.
    Vishwashree, V. K.
    Manjula, G.
    VivitaSherin, B.
    ADVANCEMENTS IN AUTOMATION AND CONTROL TECHNOLOGIES, 2014, 573 : 223 - 228