AC "Back to Back" Switching Device in Industrial Application

被引:3
|
作者
Faranda, Roberto [1 ]
Hafezi, Hossein [2 ]
Akkala, Kishore [1 ]
Lazzaroni, Massimo [3 ]
机构
[1] Politecn Milan, Dept Energy, I-20156 Milan, Italy
[2] Univ Vaasa, Sch Technol & Innovat, Elect Engn, Vaasa 65200, Finland
[3] Univ Milan, Dipartimento Fis, I-20133 Milan, Italy
关键词
back to back; electromagnetic compatibility (EMC); inductance; industrial automation; measurement; power converters; power quality; silicon-controlled rectifier (SCR); RECTIFIERS;
D O I
10.3390/en13143539
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In industrial applications, among several varieties of semiconductor devices available, a silicon-controlled rectifier (SCR) is often used in managing and protecting various systems with different applications. Hence, it is of the utmost importance to design a control system which can operate over a range of electrical loads without any modifications in its hardware and/or software. This paper analyzes and investigates in detail the power circuit effects on conduction delay and SCR functioning. Moreover, two different commonly used driving systems for SCR application have been introduced, discussed, and evaluated. Concerning driving systems, here, three aspects have paramount importance and are consequently taken into consideration, namely the driver system losses, the conduction delay, and in particular, some power quality indices. The conduction delay is a parameter of great importance, as being able to control and reduce it to the minimum allowed by the application can bring significant practical advantages (both in terms of application and economic terms, as better summarized in the article). Theoretical analysis has been performed, followed and verified by simulation studies and, for some cases, laboratory experimental test results are presented which provide credibility to the study.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Design and Control of a Lifting Assist Device for Preventing Lower Back Injuries in Industrial Athletes
    Jong-won Lee
    Gyoosuk Kim
    International Journal of Precision Engineering and Manufacturing, 2019, 20 : 1825 - 1838
  • [32] A Half-Capacity Back-to-Back Converter Interconnecting Synchronous AC Grids
    Li, Zixin
    Lei, Ming
    Wang, Zhe
    Wang, Weifan
    Wang, Ping
    Li, Yaohua
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 560 - 565
  • [33] Power Flow Management of Interconnected AC Microgrids Using Back-to-Back Converters
    Udoha, Ezenwa
    Das, Saptarshi
    Abusara, Mohammad
    ELECTRONICS, 2023, 12 (18)
  • [34] Performance and Control of a Back to Back MMC-HVDC for Asynchronous ac Networks Interconnection
    Hazem, Khaled M.
    Moustafa, Mohamed M. Zakaria
    2015 IEEE 28TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2015, : 1066 - 1071
  • [35] Design and Implementation of a Back to Back Interlinking Converter for AC-DC Microgrid Applications
    Carrasco, Dante
    Aravena, Jose
    Uriarte, Matias
    Ibaceta, Efrain
    Diaz, Matias
    Espina, Enrique
    2021 IEEE CHILEAN CONFERENCE ON ELECTRICAL, ELECTRONICS ENGINEERING, INFORMATION AND COMMUNICATION TECHNOLOGIES (IEEE CHILECON 2021), 2021, : 837 - 842
  • [36] Distance Protection Performance in AC Power System With Back-to-Back Converter Interface
    Alshehri, Jaber
    Khalid, Muhammad
    Alismail, Fahad
    2019 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2019,
  • [37] A back-to-back micromirror device for optical add/drop multiplexer applications
    Lin, YC
    Chiou, JC
    SMART SENSORS, ACTUATORS, AND MEMS, PTS 1 AND 2, 2003, 5116 : 473 - 479
  • [38] INDUSTRIAL BACK PROBLEM - ROLE OF INDUSTRIAL HYGIENIST AND ERGONOMICS
    GARRETT, JT
    AHMAD, I
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1977, 38 (10): : 560 - 562
  • [39] INDUSTRIAL DISC AND BACK PROBLEM IN WOMEN
    LONG, NG
    AMERICAN JOURNAL OF SURGERY, 1955, 89 (03): : 569 - 572
  • [40] INDUSTRIAL MEDICAL PRECAUTIONS IN BACK INJURIES
    JUNGHANNS, H
    ARBEITSMEDIZIN SOZIALMEDIZIN PRAVENTIVMEDIZIN, 1977, 12 (02): : 49 - &