Simultaneous Quantitation of Rosiglitazone and Glibenclamide in Human Plasma by LC-MS/MS; Method Development and Validation

被引:0
|
作者
Sengupta, Pinaki [1 ]
Das, Ayan [1 ]
Chatterjee, Bappaditya [1 ]
Bhaumik, Uttam [1 ]
Ghosh, Animesh [1 ]
Bose, Anirbandeep [1 ]
Pal, T. K. [1 ]
机构
[1] Jadavpur Univ, Dept Pharmaceut Technol, Bioequivalence Study Ctr, Kolkata 32, India
关键词
Rosiglitazone; glibenclamide; human plasma; method validation; LC-MS/MS;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated according to the FDA guidelines, for the simultaneous quantitation of rosiglitazone and glibenclamide in human plasma using glipizide (is an internal standard (IS). The bioanalytical method consists in the liquid-liquid extraction with a mixture of chloroform and isoamylalcohol (9:1) and quantitation by triple quadrupole mass spectrometer (API- 2000) using electrospray ionization technique, operating in multiple reaction monitoring (MRM) and positive ion mode. The compounds were eluted isocratically injecting 20 mu L aliquots of the processed samples on a C18 column with an mobile phase consisting of a mixture of aqueous ammonium formate (pH 3.0, 10 mM) and methanol. The ion transitions monitored were m/z 358 -> 135 for rosiglitazone, m/z 494 -> 369 for glibenclamide, and m/z 446 -> 321 for glipizide (internal standard, IS). The method demonstrated linearity from 5 to 800 ng/mL (r(2) = 0.998) for both the analytes with desired accuracy and precision. Intra- and inter-day precision ranged from 4 to 6 and 5 to 9% (RSD), respectively. The accuracy determined at quality control levels was within 90-105%. The validated method is very robust, accurate and requires a single IS for determination of both the analytes. This developed method proved to be reproducible and sensitive and can be used successfully to support a pharmacokinetic and/or bioequivalence study.
引用
收藏
页码:414 / 418
页数:5
相关论文
共 50 条
  • [31] Development and validation of a highly sensitive LC-MS/MS method for quantitation of bivalirudin in human plasma: application to a human pharmacokinetic study
    Chai, Dong
    Wang, Rui
    Bai, Nan
    Cai, Yun
    Liang, Beibei
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (12) : 1788 - 1793
  • [32] Development of an LC-MS/MS method for the simultaneous quantification of aripiprazole and dehydroaripiprazole in human plasma
    Song, Min
    Xu, Xinxin
    Hang, Taijun
    Wen, Aidong
    Yang, Lin
    ANALYTICAL BIOCHEMISTRY, 2009, 385 (02) : 270 - 277
  • [33] Development and validation of a LC-MS/MS method for simultaneous quantification of Ivabradine and Metoprolol in rat plasma
    Eswarudu, M. Mukkanti
    Rao, A. Lakshmana
    Vijay, K.
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2022, 116
  • [34] Validation of an LC-MS/MS method for simultaneous quantification of abiraterone, enzalutamide and darolutamide in human plasma
    Buck, Stefan A. J.
    de Bruijn, Peter
    Ghobadi-Moghaddam-Helmantel, Inge M.
    Lam, Mei H.
    de Wit, Ronald
    Koolen, Stijn L. W.
    Mathijssen, Ron H. J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1225
  • [35] Validation of an LC-MS/MS method for the simultaneous quantification of dabigatran, rivaroxaban and apixaban in human plasma
    Baldelli, Sara
    Cattaneo, Dario
    Pignatelli, Pasquale
    Perrone, Valentina
    Pastori, Daniele
    Radice, Sonia
    Violi, Francesco
    Clementi, Emilio
    BIOANALYSIS, 2016, 8 (04) : 275 - 283
  • [36] Development and validation of an LC-MS/MS method to quantify kynurenic acid in human plasma
    Liu, Renmeng
    Zhao, Xiaofeng
    Geng, Guoju
    Lai, Yurong
    BIOANALYSIS, 2022, 14 (20) : 1327 - 1336
  • [37] Development and Validation of New LC-MS/MS Method for the Determination of armodafinil in Human Plasma
    Ramesh, Devi
    Ramakrishna, Singirikonda
    Habibuddin, Mohammad
    CURRENT PHARMACEUTICAL ANALYSIS, 2012, 8 (03) : 295 - 305
  • [38] Development and validation of a LC-MS/MS method for the quantification of the regioisomers of dihydroxybutylether in human plasma
    Yuan, Bo
    Li, Li
    Fu, Yao
    Jin, Yi
    Guo, Lixin
    Xu, Haiyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 911 : 27 - 33
  • [39] METHOD OF DEVELOPMENT AND VALIDATION OF NIRAPARIB IN PLASMA SAMPLES BY LC-MS/MS
    Anil, Pamarthi
    Rahaman, Sk. Abdul
    Raj, Injety Sundar
    Ravikishore, Saiempu
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2020, : 613 - 618
  • [40] Development and validation of LC-MS/MS method for determination of plasma apixaban
    Dzudovic, Jelena
    Sakac, Milkica Crevar
    Antunovic, Marko
    Repic, Aleksandra
    Obradovic, Slobodan
    Djordjevic, Snezana
    Savic, Jelena
    Dzudovic, Boris
    ACTA CHROMATOGRAPHICA, 2022, 34 (03) : 332 - 337