Evaluating Psychophysical Polarity Sensitivity as an Indirect Estimate of Neural Status in Cochlear Implant Listeners

被引:37
|
作者
Jahn, Kelly N. [1 ]
Arenberg, Julie G. [2 ,3 ]
机构
[1] Univ Washington, Dept Speech & Hearing Sci, 1417 NE 42nd St, Seattle, WA 98105 USA
[2] Massachusetts Eye & Ear, 243 Charles St, Boston, MA 02114 USA
[3] Harvard Med Sch, Dept Otolaryngol, Boston, MA 02115 USA
来源
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY | 2019年 / 20卷 / 04期
基金
美国国家卫生研究院;
关键词
polarity effect; electrode position; imaging; psychophysics; electrical field imaging; electrode-neuron interface; STIMULATED AUDITORY-NERVE; SPEECH RECOGNITION; PARTIAL TRIPOLAR; MODEL; INTERFACE; LOUDNESS; THRESHOLDS; USERS; INTRACOCHLEAR; PERCEPTION;
D O I
10.1007/s10162-019-00718-2
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The physiological integrity of spiral ganglion neurons is presumed to influence cochlear implant (CI) outcomes, but it is difficult to measure neural health in CI listeners. Modeling data suggest that, when peripheral processes have degenerated, anodic stimulation may be a more effective neural stimulus than cathodic stimulation. The primary goal of the present study was to evaluate the emerging theory that polarity sensitivity reflects neural health in CI listeners. An ideal in vivo estimate of neural integrity should vary independently of other factors known to influence the CI electrode-neuron interface, such as electrode position and tissue impedances. Thus, the present analyses quantified the relationships between polarity sensitivity and (1) electrode position estimated via computed tomography imaging, (2) intracochlear resistance estimated via electrical field imaging, and (3) focused (steered quadrupolar) behavioral thresholds, which are believed to reflect a combination of local neural health, electrode position, and intracochlear resistance. Eleven adults with Advanced Bionics devices participated. To estimate polarity sensitivity, electrode-specific behavioral thresholds in response to monopolar, triphasic pulses where the central high-amplitude phase was either anodic (CAC) or cathodic (ACA) were measured. The polarity effect was defined as the difference in threshold response to the ACA compared to the CAC stimulus. Results indicated that the polarity effect was not related to electrode-to-modiolus distance, electrode scalar location, or intracochlear resistance. Large, positive polarity effects, which may indicate SGN degeneration, were associated with relatively high focused behavioral thresholds. The polarity effect explained a significant portion of the variation in focused thresholds, even after controlling for electrode position and intracochlear resistance. Overall, these results provide support for the theory that the polarity effect may reflect neural integrity in CI listeners. Evidence from this study supports further investigation into the use of polarity sensitivity for optimizing individual CI programming parameters.
引用
收藏
页码:415 / 430
页数:16
相关论文
共 50 条
  • [21] PSYCHOPHYSICAL STUDIES EVALUATING THE FEASIBILITY OF A SPEECH PROCESSING STRATEGY FOR A MULTIPLE-CHANNEL COCHLEAR IMPLANT
    TONG, YC
    BLAMEY, PJ
    DOWELL, RC
    CLARK, GM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1983, 74 (01): : 73 - 80
  • [23] Effect of Channel Envelope Synchrony on Interaural Time Difference Sensitivity in Bilateral Cochlear Implant Listeners
    Francart, Tom
    Lenssen, Anneke
    Buechner, Andreas
    Lenarz, Thomas
    Wouters, Jan
    EAR AND HEARING, 2015, 36 (04): : e199 - e206
  • [24] Noise Enhances Modulation Sensitivity in Cochlear Implant Listeners: Stochastic Resonance in a Prosthetic Sensory System?
    Monita Chatterjee
    Mark E. Robert
    Journal of the Association for Research in Otolaryngology, 2001, 2 : 159 - 171
  • [25] Noise enhances modulation sensitivity in cochlear implant listeners: Stochastic resonance in a prosthetic sensory system?
    Chatterjee, M
    Robert, ME
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2001, 2 (02): : 159 - 171
  • [26] Using Temporal Modulation Sensitivity to Select Stimulation Sites for Processor MAPs in Cochlear Implant Listeners
    Garadat, Soha N.
    Zwolan, Teresa A.
    Pfingst, Bryan E.
    AUDIOLOGY AND NEURO-OTOLOGY, 2013, 18 (04) : 247 - 260
  • [27] Mixed stimulation rates to improve sensitivity of interaural timing differences in bilateral cochlear implant listeners
    Thakkar, Tanvi
    Kan, Alan
    Jones, Heath G.
    Litovsky, Ruth Y.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 143 (03): : 1428 - 1440
  • [28] PSYCHOPHYSICAL STUDIES EVALUATING THE FEASIBILITY OF A SPEECH PROCESSING STRATEGY FOR A MULTIPLE-CHANNEL COCHLEAR IMPLANT.
    Tong, Y.C.
    Blamey, P.J.
    Dowell, R.C.
    Clark, G.M.
    Journal of the Acoustical Society of America, 1983, 74 (01): : 73 - 80
  • [29] Spectrotemporal Modulation Sensitivity in Cochlear-Implant and Normal-Hearing Listeners: Is the Performance Driven by Temporal or Spectral Modulation Sensitivity?
    Zhou, Ning
    Dixon, Susannah
    Zhu, Zhen
    Dong, Lixue
    Weiner, Marti
    TRENDS IN HEARING, 2020, 24
  • [30] Aversatile deep-neural-network-based music preprocessing and remixing scheme for cochlear implant listeners
    Gauer, Johannes
    Nagathil, Anil
    Eckel, Kai
    Belomestny, Denis
    Martin, Rainer
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2022, 151 (05): : 2975 - 2986