Evaluating Psychophysical Polarity Sensitivity as an Indirect Estimate of Neural Status in Cochlear Implant Listeners

被引:37
|
作者
Jahn, Kelly N. [1 ]
Arenberg, Julie G. [2 ,3 ]
机构
[1] Univ Washington, Dept Speech & Hearing Sci, 1417 NE 42nd St, Seattle, WA 98105 USA
[2] Massachusetts Eye & Ear, 243 Charles St, Boston, MA 02114 USA
[3] Harvard Med Sch, Dept Otolaryngol, Boston, MA 02115 USA
来源
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY | 2019年 / 20卷 / 04期
基金
美国国家卫生研究院;
关键词
polarity effect; electrode position; imaging; psychophysics; electrical field imaging; electrode-neuron interface; STIMULATED AUDITORY-NERVE; SPEECH RECOGNITION; PARTIAL TRIPOLAR; MODEL; INTERFACE; LOUDNESS; THRESHOLDS; USERS; INTRACOCHLEAR; PERCEPTION;
D O I
10.1007/s10162-019-00718-2
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The physiological integrity of spiral ganglion neurons is presumed to influence cochlear implant (CI) outcomes, but it is difficult to measure neural health in CI listeners. Modeling data suggest that, when peripheral processes have degenerated, anodic stimulation may be a more effective neural stimulus than cathodic stimulation. The primary goal of the present study was to evaluate the emerging theory that polarity sensitivity reflects neural health in CI listeners. An ideal in vivo estimate of neural integrity should vary independently of other factors known to influence the CI electrode-neuron interface, such as electrode position and tissue impedances. Thus, the present analyses quantified the relationships between polarity sensitivity and (1) electrode position estimated via computed tomography imaging, (2) intracochlear resistance estimated via electrical field imaging, and (3) focused (steered quadrupolar) behavioral thresholds, which are believed to reflect a combination of local neural health, electrode position, and intracochlear resistance. Eleven adults with Advanced Bionics devices participated. To estimate polarity sensitivity, electrode-specific behavioral thresholds in response to monopolar, triphasic pulses where the central high-amplitude phase was either anodic (CAC) or cathodic (ACA) were measured. The polarity effect was defined as the difference in threshold response to the ACA compared to the CAC stimulus. Results indicated that the polarity effect was not related to electrode-to-modiolus distance, electrode scalar location, or intracochlear resistance. Large, positive polarity effects, which may indicate SGN degeneration, were associated with relatively high focused behavioral thresholds. The polarity effect explained a significant portion of the variation in focused thresholds, even after controlling for electrode position and intracochlear resistance. Overall, these results provide support for the theory that the polarity effect may reflect neural integrity in CI listeners. Evidence from this study supports further investigation into the use of polarity sensitivity for optimizing individual CI programming parameters.
引用
收藏
页码:415 / 430
页数:16
相关论文
共 50 条
  • [1] Evaluating Psychophysical Polarity Sensitivity as an Indirect Estimate of Neural Status in Cochlear Implant Listeners
    Kelly N. Jahn
    Julie G. Arenberg
    Journal of the Association for Research in Otolaryngology, 2019, 20 : 415 - 430
  • [2] Polarity Sensitivity in Pediatric and Adult Cochlear Implant Listeners
    Jahn, Kelly N.
    Arenberg, Julie G.
    TRENDS IN HEARING, 2019, 23
  • [3] Polarity Sensitivity in Pediatric and Adult Cochlear Implant Listeners (vol 23, 1, 2019)
    Jahn, K. N.
    Arenberg, J. G.
    TRENDS IN HEARING, 2020, 24
  • [4] Psychophysical Tuning Curves as a Correlate of Electrode Position in Cochlear Implant Listeners
    DeVries, Lindsay
    Arenberg, Julie G.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2018, 19 (05): : 571 - 587
  • [5] Polarity Sensitivity as a Potential Correlate of Neural Degeneration in Cochlear Implant Users
    Mesnildrey, Quentin
    Venail, Frederic
    Carlyon, Robert P.
    Macherey, Olivier
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2020, 21 (01): : 89 - 104
  • [6] Polarity Sensitivity as a Potential Correlate of Neural Degeneration in Cochlear Implant Users
    Quentin Mesnildrey
    Frédéric Venail
    Robert P. Carlyon
    Olivier Macherey
    Journal of the Association for Research in Otolaryngology, 2020, 21 : 89 - 104
  • [7] Psychophysical Tuning Curves as a Correlate of Electrode Position in Cochlear Implant Listeners
    Lindsay DeVries
    Julie G. Arenberg
    Journal of the Association for Research in Otolaryngology, 2018, 19 : 571 - 587
  • [8] Effect of electrode configuration on psychophysical forward masking in cochlear implant listeners
    Kwon, BJ
    van den Honert, C
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (05): : 2994 - 3002
  • [9] The relation between polarity sensitivity and neural degeneration in a computational model of cochlear implant stimulation
    Kalkman, Randy K.
    Briaire, Jeroen J.
    Dekker, David M. T.
    Frijns, Johan H. M.
    HEARING RESEARCH, 2022, 415
  • [10] The Effects of Auditory Experience on Psychophysical Tuning Curves in Pediatric and Adult Cochlear Implant Listeners
    Arenberg, Julie G.
    DeVries, Lindsay A.
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2018, 104 (05) : 830 - 834