Augmented Reality Surgical Navigation System for External Ventricular Drain

被引:14
|
作者
Chiou, Shin-Yan [1 ,2 ,3 ]
Zhang, Zhi-Yue [1 ]
Liu, Hao-Li [4 ]
Yan, Jiun-Lin [3 ]
Wei, Kuo-Chen [5 ]
Chen, Pin-Yuan [3 ,6 ]
机构
[1] Chang Gung Univ, Coll Engn, Dept Elect Engn, Taoyuan 333, Taiwan
[2] Linkou Chang Gung Mem Hosp, Dept Nucl Med, Taoyuan 333, Taiwan
[3] Keelung Chang Gung Mem Hosp, Dept Neurosurg, Keelung 204, Taiwan
[4] Natl Taiwan Univ, Dept Elect Engn, Taipei 106, Taiwan
[5] New Taipei City TuCheng Hosp, Dept Neurosurg, New Taipei 236, Taiwan
[6] Chang Gung Univ, Sch Med, Taoyuan 333, Taiwan
关键词
surgical navigation; augmented reality; neurosurgery; 3-DIMENSIONAL ULTRASOUND; ACCURACY; MOBILE; TIME;
D O I
10.3390/healthcare10101815
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Augmented reality surgery systems are playing an increasing role in the operating room, but applying such systems to neurosurgery presents particular challenges. In addition to using augmented reality technology to display the position of the surgical target position in 3D in real time, the application must also display the scalpel entry point and scalpel orientation, with accurate superposition on the patient. To improve the intuitiveness, efficiency, and accuracy of extra-ventricular drain surgery, this paper proposes an augmented reality surgical navigation system which accurately superimposes the surgical target position, scalpel entry point, and scalpel direction on a patient's head and displays this data on a tablet. The accuracy of the optical measurement system (NDI Polaris Vicra) was first independently tested, and then complemented by the design of functions to help the surgeon quickly identify the surgical target position and determine the preferred entry point. A tablet PC was used to display the superimposed images of the surgical target, entry point, and scalpel on top of the patient, allowing for correct scalpel orientation. Digital imaging and communications in medicine (DICOM) results for the patient's computed tomography were used to create a phantom and its associated AR model. This model was then imported into the application, which was then executed on the tablet. In the preoperative phase, the technician first spent 5-7 min to superimpose the virtual image of the head and the scalpel. The surgeon then took 2 min to identify the intended target position and entry point position on the tablet, which then dynamically displayed the superimposed image of the head, target position, entry point position, and scalpel (including the scalpel tip and scalpel orientation). Multiple experiments were successfully conducted on the phantom, along with six practical trials of clinical neurosurgical EVD. In the 2D-plane-superposition model, the optical measurement system (NDI Polaris Vicra) provided highly accurate visualization (2.01 +/- 1.12 mm). In hospital-based clinical trials, the average technician preparation time was 6 min, while the surgeon required an average of 3.5 min to set the target and entry-point positions and accurately overlay the orientation with an NDI surgical stick. In the preparation phase, the average time required for the DICOM-formatted image processing and program import was 120 +/- 30 min. The accuracy of the designed augmented reality optical surgical navigation system met clinical requirements, and can provide a visual and intuitive guide for neurosurgeons. The surgeon can use the tablet application to obtain real-time DICOM-formatted images of the patient, change the position of the surgical entry point, and instantly obtain an updated surgical path and surgical angle. The proposed design can be used as the basis for various augmented reality brain surgery navigation systems in the future.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Markerless Registration for Augmented-Reality Surgical Navigation System Based on Monocular Depth Estimation
    Choi M.-H.
    Choi S.-E.
    Kang S.-R.
    Yoo J.-Y.
    Yang S.
    Kim J.-E.
    Huh K.-H.
    Lee S.-S.
    Heo M.-S.
    Yi W.-J.
    Transactions of the Korean Institute of Electrical Engineers, 2021, 70 (12): : 1898 - 1905
  • [32] Campus Navigation System Based on Mobile Augmented Reality
    Qin Yong-xu
    Liu Jia-min
    Qiu Hui
    Yan Bo
    Jin Chang-xu
    2013 6TH INTERNATIONAL CONFERENCE ON INTELLIGENT NETWORKS AND INTELLIGENT SYSTEMS (ICINIS), 2013, : 139 - 142
  • [33] AN AUGMENTED REALITY NAVIGATION SYSTEM FOR PEDIATRIC SURGERY FOR TUMORS
    Souzaki, R.
    Ieiri, S.
    Uemura, M.
    Kinoshita, Y.
    Yuhki, K.
    Suminoe, A.
    Kohashi, K.
    Oda, Y.
    Hara, T.
    Hashizume, M.
    Taguchi, T.
    PEDIATRIC BLOOD & CANCER, 2013, 60 : 47 - 47
  • [34] Public Transport Navigation System with Augmented Reality Interface
    Krolewski, Jakub
    Gawrysiak, Piotr
    CONVERGENCE AND HYBRID INFORMATION TECHNOLOGY, 2011, 206 : 545 - 551
  • [35] Building detection in augmented reality based navigation system
    Lee, Kisung
    Kim, Yongkwon
    Ch, Seong Ik
    Choi, Kyungho
    ADVANCES IN MULTIMEDIA MODELING, PT 2, 2007, 4352 : 544 - 551
  • [36] Augmented and Virtual Reality Navigation for Interventions in the Musculoskeletal System
    Belmustakov S.
    Bailey C.
    Weiss C.R.
    Current Radiology Reports, 6 (9)
  • [37] ARBIN: Augmented Reality Based Indoor Navigation System
    Huang, Bo-Chen
    Hsu, Jiun
    Chu, Edward T. -H.
    Wu, Hui-Mei
    SENSORS, 2020, 20 (20) : 1 - 20
  • [38] A Navigation and Augmented Reality System for Visually Impaired People
    Lo Valvo, Alice
    Croce, Daniele
    Garlisi, Domenico
    Giuliano, Fabrizio
    Giarre, Laura
    Tinnirello, Ilenia
    SENSORS, 2021, 21 (09)
  • [39] Benefit Analysis of Gamified Augmented Reality Navigation System
    Lee, Chun-, I
    APPLIED SCIENCES-BASEL, 2022, 12 (06):
  • [40] Indoor Navigation System Based on Augmented Reality Markers
    Sato, Fumiaki
    INNOVATIVE MOBILE AND INTERNET SERVICES IN UBIQUITOUS COMPUTING, IMIS-2017, 2018, 612 : 266 - 274