Harmonic Suppression and Stability Analysis of Three-phase VSR with Cosine Internal Model Control Strategy

被引:0
|
作者
Liu, Bo [1 ]
Ben, Hongqi [1 ]
Meng, Tao [2 ]
Bai, Yinlong [1 ]
机构
[1] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin, Peoples R China
[2] Heilongjiang Univ, Sch Mech & Elect Engn, Harbin, Peoples R China
关键词
voltage source rectifier (VSR); harmonic suppression; cosine internal model (CIM); stability boundary; FILTERS; POWER;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, low-frequency harmonics of grid current in the three-phase voltage source rectifier (VSR) are analyzed. It indicates that dead-time effect, harmonics in drive signals and harmonics in grid voltage are the main reasons why harmonics exist in the grid current. Furthermore, a self-adjusting control strategy in current loop is proposed to suppress specific harmonics based on cosine internal model (CIM) control strategy. The system stability is effected by the added controller, and its stability boundary is calculated by Jacobian matrix, which gives constraints to design the controller parameters. Tested waveforms prove that harmonics can be suppressed by the proposed control strategy, and the numerical analysis is correct.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] A Power Switching Control Strategy of Three-phase VSC Based on Power Switching Model
    Guo X.
    Pan Y.
    Li W.
    Liu J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (11): : 4459 - 4469
  • [42] Two-degree-of-freedom I-PD voltage control of three-phase PWM VSR
    Zhang, Ping-Hua
    Yang, Gui-Jie
    Li, Tie-Cai
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2009, 13 (05): : 667 - 672
  • [43] The Control Strategy Study of Three-phase Phase-locked Loop
    Xu Bei
    Su Bin
    Lin Zhiwei
    Jiang Danyu
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5885 - 5889
  • [44] Phase compensation resonant control strategy for three-phase PWM converters
    Yang, Yun-Hu
    Zhang, Jia-Yan
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2013, 17 (08): : 43 - 49
  • [45] Harmonic Current Suppression Using Single-Phase DG units in Three-Phase Grids with Unbalanced Harmonic Sources
    Yoshida, Hidehito
    Wada, Keiji
    Cheng, Po-tai
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 6239 - 6245
  • [46] Dynamic Analysis and Optimization of a Three-phase Control Mode of a Mobile System with an Internal Mass
    Fang, H. B.
    Xu, J.
    JOURNAL OF VIBRATION AND CONTROL, 2011, 17 (01) : 19 - 26
  • [47] Analysis on Harmonic Current of Three-phase Bridge Uncontrolled Rectifier
    Zhang Zheyu
    Zou Xudong
    Wu Zhenxing
    Zou Yunping
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [48] Three-Phase Harmonic Analysis Method for Unbalanced Distribution Systems
    Teng, Jen-Hao
    Liao, Shu-Hung
    Leou, Rong-Ceng
    ENERGIES, 2014, 7 (01) : 365 - 384
  • [49] Perfect Harmonic Cancellation Strategy for Three-Phase Four-Wire APF
    Xu, Lin
    Han, Yang
    Yao, Gang
    Zhou, Li-Dan
    Khan, Muhammad Mansoor
    Chen, Chen
    Pan, Jun-Min
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (10): : 65 - 70
  • [50] A Control Strategy Based on Small Signal Model for Three-Phase to Single-Phase Matrix Converters
    Chen, Si
    Ge, Hongjuan
    Zhang, Wenbin
    Lu, Song
    JOURNAL OF POWER ELECTRONICS, 2015, 15 (06) : 1456 - 1467