X-ray simulation with the Monte Carlo code PENELOPE. Application to Quality Control

被引:0
|
作者
Pozuelo, F. [1 ]
Gallardo, S. [1 ]
Querol, A. [1 ]
Verdu, G. [1 ]
Rodenas, J. [1 ]
机构
[1] Univ Politecn Valencia, Ingn Quim & Nucl Dept, Valencia 46022, Spain
来源
2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2012年
关键词
FILTRATION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A realistic knowledge of the energy spectrum is very important in Quality Control (QC) of X-ray tubes in order to reduce dose to patients. However, due to the implicit difficulties to measure the X-ray spectrum accurately, it is not normally obtained in routine QC. Instead, some parameters are measured and/or calculated. PENELOPE and MCNP5 codes, based on the Monte Carlo method, can be used as complementary tools to verify parameters measured in QC. These codes allow estimating Bremsstrahlung and characteristic lines from the anode taking into account specific characteristics of equipment. They have been applied to simulate an X-ray spectrum. Results are compared with theoretical IPEM 78 spectrum. A sensitivity analysis has been developed to estimate the influence on simulated spectra of important parameters used in simulation codes. With this analysis it has been obtained that the FORCE factor is the most important parameter in PENELOPE simulations. FORCE factor, which is a variance reduction method, improves the simulation but produces hard increases of computer time. The value of FORCE should be optimized so that a good agreement of simulated and theoretical spectra is reached, but with a reduction of computer time. Quality parameters such as Half Value Layer (HVL) can be obtained with the PENELOPE model developed, but FORCE takes such a high value that computer time is hardly increased. On the other hand, depth dose assessment can be achieved with acceptable results for small values of FORCE.
引用
收藏
页码:5777 / 5780
页数:4
相关论文
共 50 条
  • [11] Monte Carlo simulation of x-ray spectra in mammography
    Ng, KP
    Kwok, CS
    Tang, FH
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05): : 1309 - 1318
  • [12] Benchmarking of a Module for the Monte Carlo Simulation of Proton Transport in the PENELOPE Code
    Verbeek, N.
    Smyczek, S.
    Wulff, J.
    Baeumer, C.
    Timmermann, B.
    Brualla, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S179 - S179
  • [13] Benchmarking of a module for Monte Carlo simulation of proton transport in the PENELOPE code
    Verbeek, N.
    Smyczek, S.
    Wulff, J.
    Baeumer, C.
    Timmermann, B.
    Brualla, L.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S479 - S480
  • [14] Accurate simulation of ionisation chamber response with the Monte Carlo code PENELOPE
    Sempau, Josep
    Andreo, Pedro
    XXXIII BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2011, 1351
  • [15] GXPS: A Geant4-based Monte Carlo code for x-ray polycapillary simulation
    Chi, Zhijun
    JOURNAL OF APPLIED PHYSICS, 2020, 128 (12)
  • [16] Monte Carlo simulation of X-ray room shielding in diagnostic radiology using PHITS code
    Abdul Aziz, M. Z.
    Yani, S.
    Haryanto, F.
    Ya Ali, N. Kamarullah
    Tajudin, S. M.
    Iwase, H.
    Musarudin, M.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2020, 13 (01) : 704 - 713
  • [17] Experimental benchmarks of the Monte Carlo code PENELOPE
    Sempau, J
    Fernández-Varea, JM
    Acosta, E
    Salvat, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 207 (02): : 107 - 123
  • [18] Beam Quality of Flat Panel X-Ray Source Using Monte Carlo Simulation
    Ding, Z.
    Yang, S.
    Huang, J.
    Zhou, L.
    Xu, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E493 - E493
  • [19] X-ray spectra and quality parameters from Monte Carlo simulation and analytical filters
    Salehi, Z.
    Ali, N. K. Ya
    Yusoff, A. L.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (11) : 2586 - 2589
  • [20] On the behavior of fc,Q factors with quality indexes for medium energy X-ray beams: A Monte Carlo study with PENELOPE
    Chica, U.
    Anguiano, M.
    Lallena, A. M.