Four-dimensional cone-beam computed tomography-guided radiotherapy for gastric lymphoma

被引:6
|
作者
Toya, Ryo [1 ]
Saito, Tetsuo [1 ]
Shimohigashi, Yoshinobu [2 ]
Yotsuji, Yohei [2 ]
Matsuyama, Tomohiko [1 ]
Watakabe, Takahiro [1 ]
Kai, Yudai [2 ]
Yamashita, Yasuyuki [3 ]
Oya, Natsuo [1 ]
机构
[1] Kumamoto Univ Hosp, Dept Radiat Oncol, Chuo Ku, 1-1-1 Honjo, Kumamoto 8608556, Japan
[2] Kumamoto Univ Hosp, Dept Radiol Technol, Kumamoto, Japan
[3] Kumamoto Univ Hosp, Dept Diagnost Radiol, Kumamoto, Japan
关键词
Gastric lymphoma; Four-dimensional conebeam computed tomography; Image-guided radiotherapy; Internal target volume; Respiratory motion; RADIATION; STOMACH;
D O I
10.1007/s11604-017-0698-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We describe a treatment method with four-dimensional cone-beam computed tomography (4D-CBCT)-guided radiotherapy for gastric lymphoma. We performed image-guided radiotherapy (IGRT) with 15 fractions for a gastric mucosa-associated lymphoid tissue lymphoma patient, using 4D-CBCT. The stomach was delineated based on 4D-CT images. For image guidance, an automatic registration between planning CT and 4D-CBCT images was performed based on the bony anatomy (bone matching), followed by manual registration based on the stomach in 4D-CBCT images of all 10 phases (4D matching). We calculated the covering ratio (CR) with variable stomach-to-planning target volume (PTV) margins, based on the images of all phases [CR (%) = the number of covering phases/all 150 phases x 100]. The patient underwent radiotherapy (RT) as scheduled, without any significant adverse effects. The appropriate PTV margins (CR ae<yen> 95%) were 25 mm (CR 99.3%) and 15 mm (CR 98.7%) for bone and 4D matching, respectively. 4D matching using 4D-CBCT is appropriate for IGRT of gastric lymphomas.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [41] Assessment of the therapeutic accuracy of cone beam computed tomography-guided nasopharyngeal carcinoma radiotherapy
    Liu, Jiabin
    Lyman, Khumbula Maitireazvo
    Ding, Zhenhua
    Zhou, Liang
    ONCOLOGY LETTERS, 2019, 18 (02) : 1071 - 1080
  • [42] Micro-Computed Tomography-Guided Artificial Intelligence for Pulp Cavity and Tooth Segmentation on Cone-beam Computed Tomography
    Lin, Xiang
    Fu, Yujie
    Ren, Genqiang
    Yang, Xiaoyu
    Duan, Wei
    Chen, Yufei
    Zhang, Qi
    JOURNAL OF ENDODONTICS, 2021, 47 (12) : 1933 - 1941
  • [43] Dose Verification of Four-Dimensional Cone-Beam Computed Tomography for Target Localization of Planned and Unplanned Target Motion
    Baley, C.
    Stathakis, S.
    Myers, P.
    Kirby, N.
    Rasmussen, K.
    Papanikolaou, N.
    Saenz, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E605 - E606
  • [44] Motion-map constrained image reconstruction (MCIR): Application to four-dimensional cone-beam computed tomography
    Park, Justin C.
    Kim, Jin Sung
    Park, Sung Ho
    Liu, Zhaowei
    Song, Bongyong
    Song, William Y.
    MEDICAL PHYSICS, 2013, 40 (12)
  • [45] Development of a markerless tumor-tracking algorithm using prior four-dimensional cone-beam computed tomography
    Chhatkuli, Ritu Bhusal
    Demachi, Kazuyuki
    Uesaka, Mitsuru
    Nakagawa, Keiichi
    Haga, Akihiro
    JOURNAL OF RADIATION RESEARCH, 2019, 60 (01) : 109 - 115
  • [46] The accuracy of extracted target motion trajectories in four-dimensional cone-beam computed tomography for lung cancer patients
    Iramina, Hiraku
    Nakamura, Mitsuhiro
    Iizuka, Yusuke
    Mitsuyoshi, Takamasa
    Matsuo, Yukinori
    Mizowaki, Takashi
    Hiraoka, Masahiro
    Kanno, Ikuo
    RADIOTHERAPY AND ONCOLOGY, 2016, 121 (01) : 46 - 51
  • [47] Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
    Sun, Xiaolin
    Hao, Yimeng
    Kiekenap, Jonathan Frederik Sebastian
    Emeis, Jasper
    Steitz, Marvin
    Breitenstein-Attach, Alexander
    Berger, Felix
    Schmitt, Boris
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (179):
  • [48] Where are we on (preventing) pneumothorax after (cone-beam) computed tomography-guided lung biopsy?
    Vestering, Myrthe M.
    Braak, Sicco J.
    JOURNAL OF THORACIC DISEASE, 2015, 7 (09) : E341 - E343
  • [49] Target-specific optimization of four-dimensional cone beam computed tomography
    Ahmad, Moiz
    Pan, Tinsu
    MEDICAL PHYSICS, 2012, 39 (09) : 5683 - 5696
  • [50] Target-Specific Optimization of Four-Dimensional Cone Beam Computed Tomography
    Ahmad, M.
    Pan, T.
    MEDICAL PHYSICS, 2012, 39 (06) : 3682 - 3682