Retinal Nerve Fiber Layer Thickness Reproducibility Using Seven Different OCT Instruments

被引:111
|
作者
Pierro, Luisa [1 ]
Gagliardi, Marco [1 ]
Iuliano, Lorenzo [1 ]
Ambrosi, Alessandro [2 ]
Bandello, Francesco [1 ]
机构
[1] Univ Vita Salute San Raffaele, Dept Ophthalmol, San Raffaele Sci Inst, I-20132 Milan, Italy
[2] Univ Vita Salute San Raffaele, Milan, Italy
关键词
OPTICAL COHERENCE TOMOGRAPHY; SPECTRAL-DOMAIN OCT; CIRRUS-HD-OCT; TIME-DOMAIN; NORMAL EYES; HEALTHY EYES; COMPARABILITY; OCT/SLO; RTVUE;
D O I
10.1167/iovs.11-8644
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The clinical utility of new optical coherence tomography (OCT) instruments strongly depends on measurements reproducibility. The aim of this study was to assess retinal nerve fiber layer (RNFL) thickness reproducibility using six different spectral-domain OCTs (SD-OCTs) and one time-domain OCT. METHODS. RNFL thickness (average and four quadrant) from six SD-OCTs (Spectral OCT/SLO OPKO/OTI, 3D-OCT 2000 Topcon, RS-3000 NIDEK, Cirrus HD-OCT Zeiss, RTVue-100 Optovue, and Spectralis Heidelberg) and one time-domain OCT (Stratus OCT Zeiss) was measured twice in 38 right eyes of 38 randomly chosen healthy volunteers by two masked operators. Inter-and intraoperator reproducibility was evaluated by the intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measures. We also tested how the devices disagree in terms of systemic bias and random error using a structural equation model. RESULTS. Mean RNFL average thickness ranged from 90.08 mu m to 106.51 mu m. Cirrus and Heidelberg showed the thinnest RNFL values in all measurements, Topcon the highest. ICC, CV, and Bland-Altman plots showed variable inter- and intraoperator agreement depending on the instrument. Heidelberg demonstrated the best interoperator (ICC, 0.92; CV, 1.56%) and intraoperator (ICC, 0.94 and 0.95; CV, 1.28% and 1.26%, respectively, for operator A and operator B) agreement for average RNFL thickness. CONCLUSIONS. Heidelberg demonstrated the higher agreement in inter-and intraoperator reproducibility, Optovue the worst. In light of our error analysis results, we found that a scale bias among instruments could interfere with a thorough RNFL monitoring, suggesting that best monitoring is obtained with the same operator and the same device. (Invest Ophthalmol Vis Sci. 2012; 53: 5912-5920) DOI:10.1167/iovs.11-8644
引用
收藏
页码:5912 / 5920
页数:9
相关论文
共 50 条
  • [31] Evaluation of Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness in Axial Myopia Using SD OCT
    AttaAllah H.R.
    Omar I.A.N.
    Abdelhalim A.S.
    Ophthalmology and Therapy, 2017, 6 (2) : 335 - 341
  • [32] Comparing retinal nerve fiber layer thickness between SD-OCT and AO-OCT
    King, Brett
    Swanson, William H.
    Kurokawa, Kazuhiro
    Miller, Donald Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [33] The Role of the Retinal Nerve Fiber Layer Thickness on OCT in the Evaluation of Papillitis in Childhood Uveitis
    V. Kouwenberg, Carlyn
    Blom, Laurens A.
    Vellinga, Suzanne C.
    Bozkir, Irem
    de Boer, Joke H.
    Ayuso, Viera Koopman-Kalinina
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 254 : 62 - 68
  • [34] Association of Birth Parameters with OCT Measured Macular and Retinal Nerve Fiber Layer Thickness
    Tariq, Yasser M.
    Pai, Amy
    Li, Haitao
    Afsari, Sonia
    Gole, Glen A.
    Burlutsky, George
    Mitchell, Paul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1709 - 1715
  • [35] REPEATABILITY AND REPRODUCIBILITY OF OPTIC NERVE HEAD AND RETINAL NERVE FIBER LAYER PARAMETER MEASUREMENTS WITH THE HEIDELBERG SPECTRALIS OCT
    Mardin, Christian Y.
    Schrems, Wolfgang
    Schrems-Hoesl, Laura -Maria
    Laemmer, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [36] Comparison of retinal nerve fiber layer thickness measurements using different stratus-OCT scan protocols in patients with early glaucoma
    Hougaard, JL
    Bengtsson, B
    Ostenfeld, C
    Heijl, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [37] Retinal nerve fiber layer assessed by OCT in different forms of multiple sclerosis
    Meyniel, Claire
    Vasseur, Vivien
    Gout, Olivier
    NEUROLOGY, 2008, 70 (11) : A261 - A261
  • [38] Reproducibility of Peripapillary Retinal Nerve Fiber Thickness Measurement With Spectral Domain OCT(Spectralis) in Glaucomatous Eyes
    Kim, M.
    An, G.
    Park, K.
    Kim, D.
    Kim, T. -W.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [39] Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments
    Bourne, RRA
    Medeiros, FA
    Bowd, C
    Jahanbakhsh, K
    Zangwill, LM
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) : 1280 - 1285
  • [40] Comparison of Retinal Nerve Fiber Layer Measurement Between 2 Spectral Domain OCT Instruments
    Tan, Benjamin B.
    Natividad, Maricel
    Chua, Kia-Chong
    Yip, Leonard W.
    JOURNAL OF GLAUCOMA, 2012, 21 (04) : 266 - 273