PURPOSE. The clinical utility of new optical coherence tomography (OCT) instruments strongly depends on measurements reproducibility. The aim of this study was to assess retinal nerve fiber layer (RNFL) thickness reproducibility using six different spectral-domain OCTs (SD-OCTs) and one time-domain OCT. METHODS. RNFL thickness (average and four quadrant) from six SD-OCTs (Spectral OCT/SLO OPKO/OTI, 3D-OCT 2000 Topcon, RS-3000 NIDEK, Cirrus HD-OCT Zeiss, RTVue-100 Optovue, and Spectralis Heidelberg) and one time-domain OCT (Stratus OCT Zeiss) was measured twice in 38 right eyes of 38 randomly chosen healthy volunteers by two masked operators. Inter-and intraoperator reproducibility was evaluated by the intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measures. We also tested how the devices disagree in terms of systemic bias and random error using a structural equation model. RESULTS. Mean RNFL average thickness ranged from 90.08 mu m to 106.51 mu m. Cirrus and Heidelberg showed the thinnest RNFL values in all measurements, Topcon the highest. ICC, CV, and Bland-Altman plots showed variable inter- and intraoperator agreement depending on the instrument. Heidelberg demonstrated the best interoperator (ICC, 0.92; CV, 1.56%) and intraoperator (ICC, 0.94 and 0.95; CV, 1.28% and 1.26%, respectively, for operator A and operator B) agreement for average RNFL thickness. CONCLUSIONS. Heidelberg demonstrated the higher agreement in inter-and intraoperator reproducibility, Optovue the worst. In light of our error analysis results, we found that a scale bias among instruments could interfere with a thorough RNFL monitoring, suggesting that best monitoring is obtained with the same operator and the same device. (Invest Ophthalmol Vis Sci. 2012; 53: 5912-5920) DOI:10.1167/iovs.11-8644
引用
收藏
页码:5912 / 5920
页数:9
相关论文
共 50 条
  • [1] Reproducibility of peripapillary retinal nerve fiber layer thickness measurements using Spectral Domain OCT in Brazilian patients
    Toscano, Daniela Araujo
    de Avila, Marcos Pereira
    Catai Chalita, Maria Regina
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (05) : 320 - 323
  • [2] Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3)
    Gürses-Özden, R
    Teng, C
    Vessani, R
    Zafar, S
    Liebmann, JM
    Ritch, R
    JOURNAL OF GLAUCOMA, 2004, 13 (03) : 238 - 244
  • [3] Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3)
    Teng, CC
    Gurses-Ozden, R
    Vessani, RM
    Makornwattana, M
    Rubin, B
    Zafar, S
    Liebmann, JM
    Tello, C
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U234 - U234
  • [4] Retinal nerve fiber layer thickness in children measured with OCT
    Salchow, DJ
    Chiang, MF
    Tsai, J
    Langton, K
    Al-Aswad, LA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [5] Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
    Budenz, DL
    Chang, RT
    Huang, XR
    Knighton, RW
    Tielsch, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2440 - 2443
  • [6] Reproducibility of peripapillary retinal nerve fiber layer thickness measurements with Cirrus HD-OCT in glaucomatous eyes
    Reza Soltani-Moghadam
    Yousef Alizadeh
    Ehsan Kazemnezhad Leili
    Mohamadreza Absari Haghighi
    International Journal of Ophthalmology, 2015, (01) : 113 - 117
  • [7] Reproducibility of peripapillary retinal nerve fiber layer thickness measurements with Cirrus HD-OCT in glaucomatous eyes
    Soltani-Moghadam, Reza
    Alizadeh, Yousef
    Leili, Ehsan Kazemnezhad
    Haghighi, Mohamadreza Absari
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (01) : 113 - 117
  • [8] REPRODUCIBILITY OF RETINAL NERVE-FIBER LAYER THICKNESS MEASUREMENTS USING THE NERVE-FIBER ANALYZER-II
    REITER, K
    BAILEY, ED
    DREHER, AW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S972 - S972
  • [9] Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes
    Budenz, Donald L.
    Fredette, Marie-Josee
    Feuer, William J.
    Anderson, Douglas R.
    OPHTHALMOLOGY, 2008, 115 (04) : 661 - 666
  • [10] Custom measurement of retinal nerve fiber layer thickness using STRATUS OCT in normal eyes
    Carpineto, P
    Ciancaglini, M
    Aharrh-Gnama, A
    Cirone, D
    Mastropasqua, L
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (03) : 360 - 366