Rapid On-site Monitoring of Organophosphorus Insecticide Chlorpyrifos Residue Using Simple Plastic Lab-on-a-Chip

被引:1
|
作者
Chaumpluk, P. [1 ]
Janduang, T. [2 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Dept Bot, Lab Plant Transgen Technol & Biosensor, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Sci, Sci Instrument Serv & Dev Unit, Bangkok 10330, Thailand
关键词
Chlorpyrifos sensor; plastic chip; colorimetric detection; Aptamer; AuNPs; UNMODIFIED GOLD NANOPARTICLES; COLORIMETRIC DETECTION; DNA APTAMER; PESTICIDES; SELECTION; WATER; CHEMILUMINESCENT; OCHRATOXIN; APTASENSOR; BIOSENSORS;
D O I
10.1117/12.2267756
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
On-site detection of chlorpyrifos, the most commonly used insecticide, is still a challenge for food safety concerns. So far, different chromatographic methods and immunological methods have been used for chlorpyrifos assays due to their reliability and sensitivity, yet they have been time-consuming, depended too much on expensive facilities and needed a lot of technical skills, making them unsuitable for on-site screening. In this study, a plastic lab-on-a-chip was developed to rapidly detect chlorpyrifos residue. The 1.8x5.3 cm. acrylic chip was fabricated using an engraving machine. It had two parts, a sample socket for sample application and a reaction part for chlorpyrifos signal detection. The simple and rapid chlorpyrifos assay combining a chlorpyrifos specific aptamer and colorimetric detection using gold nanoparticle was in its entirety operated on the acrylic plastic chip. The sample was just applied to the chip via a sample socket, then the chip was sealed with a sticker and flicked forward to get the gold nanoparticles/aptamer solution mixed and flicked backward to see the result. When chlorpyrifos was present in a sample, a binding between chlorpyrifos and aptamer protected the gold nanoparticles from salt induced aggregation, leaving a distinct ruby red color on the chip, whereas when chlorpyrifos was absent, the aptamer would induce particle aggregation leaving only purple color. The assay completion requires less than 10 minutes, has a limit of detection (LOD) of 10 ppb, and has high specificity (100%) and sensitivity (100%). When this was used to identify chlorpyrifos residue in commercial samples, residue contamination was identified in 6 of 30 samples tested (20.00%). This work demonstrates the fabrication of a simple, low-cost, paperbased lab-on-a-chip platform suitable for rapid-detection applications.
引用
收藏
页数:14
相关论文
共 43 条
  • [31] Environmental Fate Modeling of Nanoplastics in a Salinity Gradient Using a Lab-on-a-Chip: Where Does the Nanoscale Fraction of Plastic Debris Accumulate?
    Venel, Zelie
    Tabuteau, Herve
    Pradel, Alice
    Pascal, Pierre-Yves
    Grassl, Bruno
    El Hadri, Hind
    Baudrimont, Magalie
    Gigault, Julien
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (05) : 3001 - 3008
  • [32] Rapid On-Site Monitoring of Bacteria in Freshwater Environments Using a Portable Microfluidic Counting System
    Yamaguchi, Nobuyasu
    Fujii, Yudai
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2020, 43 (01) : 87 - 92
  • [33] On-site rapid and simultaneous detection of acetamiprid and fipronil using a dual-fluorescence lab-on-fiber biosensor
    Dan Song
    Jiayao Liu
    Wenjuan Xu
    Xiangzhi Han
    Hongliang Wang
    Yuxin Zhuo
    Chunsheng Li
    Feng Long
    Microchimica Acta, 2022, 189
  • [34] On-site rapid and simultaneous detection of acetamiprid and fipronil using a dual-fluorescence lab-on-fiber biosensor
    Song, Dan
    Liu, Jiayao
    Xu, Wenjuan
    Han, Xiangzhi
    Wang, Hongliang
    Zhuo, Yuxin
    Li, Chunsheng
    Long, Feng
    MICROCHIMICA ACTA, 2022, 189 (06)
  • [35] Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
    Yamaguchi, Nobuyasu
    Tokunaga, Yusuke
    Goto, Satoko
    Fujii, Yudai
    Banno, Fumiya
    Edagawa, Akiko
    SCIENTIFIC REPORTS, 2017, 7
  • [36] Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
    Nobuyasu Yamaguchi
    Yusuke Tokunaga
    Satoko Goto
    Yudai Fujii
    Fumiya Banno
    Akiko Edagawa
    Scientific Reports, 7
  • [37] Rapid on-site monitoring of fatty acid profile in raw milk using a handheld near infrared sensor
    Llano Suarez, P.
    Soldado, A.
    Gonzalez-Arrojo, A.
    Vicente, F.
    de la Roza-Delgado, B.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2018, 70 : 1 - 8
  • [38] A stretchable glove sensor toward rapid monitoring of trifluralin: A new platform for the on-site recognition of herbicides based on wearable flexible sensor technology using lab-on-glove
    Mahmoudpour, Mansour
    Saadati, Arezoo
    Hasanzadeh, Mohammad
    Kholafazad-kordasht, Houman
    JOURNAL OF MOLECULAR RECOGNITION, 2021, 34 (10)
  • [39] An On-Site Serology Monitoring System Consisting of a Multiplex Microfluidic Chip Fabricated Using the Electrospray Deposition Method for Laboratory Mice
    Aoki, Hiroyoshi
    Kaneko, Ai
    Kajita, Ayako
    Yamagata, Yutaka
    Ike, Fumio
    Kase, Hiroshi
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2012, 45 (07) : 528 - 538
  • [40] Rapid and accurate on-site identification of Lactobacillus delbrueckii subspecies in dairy products using direct polymerase chain reaction with microfluidic chip
    Kim, Eiseul
    Lee, Ga-Young
    Yang, Seung-Min
    Kim, Hae-Yeong
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2023, 179