Background: The structural importance of the spring ligament complex in arch stability has been described. Furthermore, the pathology of this complex is often noted in patients with posterior tibial tendon dysfunction. The purpose of this biomechanical study was to evaluate spring ligament repair alone versus augmentation with the FiberTape device in a cadaveric flatfoot model. Methods: Eight paired, below-the-knee, cadaveric specimens underwent flatfoot creation and reconstruction. The experimental group received augmentation with FiberTape (InternalBrace). After potting, specimens were loaded statically to measure talonavicular contact pressures and flatfoot correction. Cyclic loading was performed in a stepwise fashion. Loading was performed at 1 Hz and 100 cycles, at 100-N intervals from 500 to 1800 N, with the Achilles tendon also loaded to simulate weightbearing in the postoperative period. Results: Control specimen analysis demonstrated failures of 8 of 8 (100%) spring ligament suture repairs, occurring through suture cut-through (5 specimens), suture fatigue and elongation (2), or knot failure (1). One of 8 (12.5%) FiberTape-augmented repairs failed after cyclic loading. The difference in number of repair failures was statistically significant between the 2 groups (P = .0014). Analysis revealed that at forces of 1600 N (P = .03) and 1700 N (P = .02) there were statistically significant differences between the FiberTape-augmented group and the control group, with a greater collapse in the lateral Meary talo-first metatarsal angle in the controls. There was no significant difference or abnormal increase in contact pressures of the talonavicular joint in both groups. Conclusion: FiberTape augmentation of the spring ligament appears biomechanically safe and effective under cyclic loading.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 50 条
  • [31] Biomechanical evaluation of hydroxyapatite intervertebral graft and anterior cervical plating in a porcine cadaveric model
    Takahashi, T
    Tominaga, T
    Yoshimoto, T
    Koshu, K
    Yokobori, AT
    Aizawa, Y
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1997, 7 (02) : 121 - 127
  • [32] Suture-Based Distal Radioulnar Joint Stabilization: A Biomechanical Evaluation in a Cadaveric Model
    Graf, Alexander R.
    Ahmed, Adil S.
    Thompson, Dan
    Gottschalk, Michael B.
    Wagner, Eric R.
    Suh, Nina
    JOURNAL OF WRIST SURGERY, 2025, 14 (02) : 114 - 120
  • [33] Biomechanical Comparison of Fiber Tape Device Versus Transarticular Screws for Ligamentous Lisfranc Injury in a Cadaveric Model
    Koroneos, Zachary A.
    Manto, Kristen M.
    Martinazzi, Brandon J.
    Stauch, Chris
    Bifano, Shawn M.
    Kunselman, Allen R.
    Lewis, Gregory S.
    Aynardi, Michael
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (12): : 3299 - 3307
  • [34] EVALUATION OF ANTERIOR CRUCIATE RECONSTRUCTION REINFORCED BY THE KENNEDY LIGAMENT AUGMENTATION DEVICE - AN ARTHROSCOPIC AND HISTOLOGICAL STUDY
    ASAHINA, S
    YAMAMOTO, H
    MUNETA, T
    ISHIBASHI, T
    FURUYA, K
    INTERNATIONAL ORTHOPAEDICS, 1995, 19 (04) : 229 - 233
  • [35] Nonanatomic versus anatomic techniques in spring ligament reconstruction: biomechanical assessment via a finite element model
    Can Xu
    Ming qing Li
    Chenggong Wang
    Hua Liu
    Journal of Orthopaedic Surgery and Research, 14
  • [36] Nonanatomic versus anatomic techniques in spring ligament reconstruction: biomechanical assessment via a finite element model
    Xu, Can
    Li, Ming Qing
    Wang, Chenggong
    Liu, Hua
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [37] Evaluation of a Novel Needle Decompression Device Against Standard of Care: A Cadaveric Model
    Myers, John C.
    Achay, Jennifer
    Limon, David
    Gerhardus, Christian
    Eastridge, Brian
    Gelfond, Jonathan
    Willis, Ross
    Nicholson, Susannah
    Bynum, Jim
    MILITARY MEDICINE, 2024,
  • [38] Development of an Animal Fracture Model for Evaluation of Cement Augmentation Femoroplasty: An In Vitro Biomechanical Study
    Luo, Qiang
    Lu, William W.
    Lau, Tak-Wing
    Leung, Frankie
    BIORESEARCH OPEN ACCESS, 2014, 3 (02): : 70 - 74
  • [39] Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model
    Hoegel, F.
    Mair, S.
    Eberle, S.
    Weninger, P.
    von Oldenburg, G.
    Augat, P.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (01) : 51 - 57
  • [40] Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model
    F. Högel
    S. Mair
    S. Eberle
    P. Weninger
    G. von Oldenburg
    P. Augat
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 51 - 57