Energy efficiency solutions for RO desalination plant

被引:2
|
作者
Bhutani, Naveen [1 ]
Purohit, Amit [1 ]
Mantravadi, Vasudeva Kumar [1 ]
Mekapati, Srinivas [1 ]
Subbaiah, Senthilmurugan [2 ]
机构
[1] ABB Corp Res, Bangalore, Karnataka, India
[2] ABB Water ISI, Bangalore, Karnataka, India
关键词
Energy efficiency; Energy assessment; Desalination; Reverse osmosis; Cost benefit; Membrane performance monitoring; Decision Support System; SEAWATER;
D O I
10.1080/19443994.2013.795258
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Asea Brown Boveri (ABB) provides a portfolio of energy efficiency solutions for reverse osmosis (RO) based desalination plant. ABB has developed: (1) Energy and carbon footprint assessment tool in order to identify the opportunities for energy efficiency improvements and quantify them into economic benefits, (2) Membrane Performance (MP) tool to monitor and optimize the operations in RO plant, and (3) Decision Support System (DSS) to help the engineer while planning the membrane maintenance and production activities. In this study, the energy assessment was first performed on a RO plant to identify the opportunities for improvement. Subsequently, the identified opportunities are evaluated using MP tool on the plant data. Further, the benefits associated with DSS are also discussed using the simulated data.
引用
收藏
页码:5049 / 5055
页数:7
相关论文
共 50 条
  • [41] Optimization coupling RO desalination unit to renewable energy by genetic algorithms
    Ben M'Barek, T.
    Bourouni, K.
    Ben Mohamed, K. B.
    DESALINATION AND WATER TREATMENT, 2013, 51 (7-9) : 1416 - 1428
  • [42] ANALYSIS OF THERMAL EFFICIENCY OF ATOMIC ENERGY PLANTS COMBINED WITH HIGH-CAPACITY DESALINATION PLANT
    STERMAN, LS
    MOZHAROV, NA
    GUBENKO, VV
    THERMAL ENGINEERING, 1968, 15 (10) : 62 - &
  • [43] eDNA metabarcoding of marine invertebrate communities at RO desalination plant outfalls in Cyprus
    Grammatiki, K.
    de Jonge, N.
    Nielsen, J. L.
    Garcia-Gomez, S. C.
    Avramidi, E.
    Lymperaki, M. M.
    Marcou, M.
    Ioannou, G.
    Papatheodoulou, M.
    Dargent, O.
    Xevgenos, D.
    Hesselsoe, M.
    Kupper, F. C.
    MARINE POLLUTION BULLETIN, 2025, 214
  • [44] Performance of ultrafiltration and coagulation in an UF-RO seawater desalination demonstration plant
    Schurer, Rinnert
    Janssen, Arie
    Villacorte, Loreen
    Kennedy, Maria
    DESALINATION AND WATER TREATMENT, 2012, 42 (1-3) : 57 - 64
  • [45] Pilot plant evaluation of advanced vs conventional scale inhibitors for RO desalination
    Butt, FH
    Rahman, F
    Baduruthamal, U
    DESALINATION, 1995, 103 (03) : 189 - 198
  • [46] Performance evaluation of five years operation experience of WMZM RO desalination plant
    Yassin, Aziz Y.
    Ghandour, Ibrahim
    DESALINATION AND WATER TREATMENT, 2014, 52 (16-18) : 2939 - 2955
  • [47] OPERATING EXPERIENCE ON RO SEA-WATER DESALINATION PLANT AT CHIGASAKI LABORATORY
    KUNISADA, Y
    OHTA, K
    KANEDA, H
    HIRAI, M
    MURAYAMA, Y
    DESALINATION, 1981, 39 (1-3) : 413 - 421
  • [48] DESIGN AND OPERATION OF A 5 ML/D RO DESALINATION PLANT IN ARID AUSTRALIA
    WATSON, B
    MARKS, G
    GABBRIELLI, E
    CHAPPLE, L
    DESALINATION, 1994, 96 (1-3) : 369 - 377
  • [49] Phosboucraa desalination plant for the phosphate industry - optimization of process unit and RO performance
    El Boury, K.
    Ghrib, A.
    El Aroui, K.
    M'hamedi, R.
    Kababi, A.
    Taky, M.
    Elmidaoui, A.
    DESALINATION AND WATER TREATMENT, 2010, 18 (1-3) : 151 - 156
  • [50] The key to efficient RO desalination
    Brewer, Peter
    FILTRATION & SEPARATION, 2016, 53 (03): : 22 - 24