High-Sensitivity Cardiac Troponin I Levels in Normal and Hypertensive Pregnancy

被引:24
|
作者
Ravichandran, Jeganathan [1 ]
Woon, Shu Yuan [1 ]
Quek, Yek Song [1 ]
Lim, Yee Chern [1 ]
Noor, Eliza Mohd [1 ]
Suresh, Kumar [1 ]
Vigneswaran, Ramakrishnan [1 ]
Vasile, Vlad [2 ]
Shah, Anoop [3 ]
Mills, Nicholas L. [3 ]
Sickan, Jeganathan [4 ]
Beshiri, Agim [4 ]
Jaffe, Allan S. [2 ]
机构
[1] Hosp Sultanah Aminah Johor Bahru, Johor Baharu, Malaysia
[2] Mayo Clin, Rochester, MN USA
[3] Univ Edinburgh, Edinburgh, Midlothian, Scotland
[4] Abbott Labs, Chicago, IL USA
来源
AMERICAN JOURNAL OF MEDICINE | 2019年 / 132卷 / 03期
关键词
High sensitivity troponin; Hypertension; Pregnancy;
D O I
10.1016/j.amjmed.2018.11.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PURPOSE: The purpose of this study was to examine the association of circulating concentrations of high-sensitivity cardiac troponin I (hs-cTn) in the various trimesters of pregnancy in patients with and without hypertension. METHODS: This was a prospective cross-sectional study of pregnant and postnatal women aged between 18-35 years with no coexisting diseases. Serum samples were analysed for hs-TnI. RESULTS: A total of 880 women (mean age = 29.1 years [standard deviation = 5.1 years]) were recruited with 129 (14%), 207 (24%), and 416 (47%) patients in the first, second, and third trimesters, respectively. Ninety (10%) participants were recruited in the postnatal period. During pregnancy 28 (3%) patients were classified as having pregnancy-induced hypertension and 10 (1%) as preeclampsia. High-sensitivity cardiac troponin I was measurable in 546 (62%) participants with a median of 1 ng/L (range 0 to 783 ng/L). Troponin concentrations were above the 99th percentile in 19 (2%) individuals. Patients with pregnancy-induced hypertension and preeclampsia had higher concentrations of hs-TnI (median 11 ng/L [interquartile range (IQR) 6 to 22 ng/L] vs 12ng/L [IQR 3 to 98 ng/L] vs 1 ng/L [IQR 0 to 1 ng/L]). In logistic regression modeling hs-cTnI concentration remained an independent predictor of pregnancy-induced hypertension or preeclampsia in both unadjusted and adjusted models (odds ratio 9.3 [95% confidence interval 5.8 to 16.3] and 11.5 [95% confidence interval 6.3 to 24.1], respectively, per doubling of hs-TnI concentrations). CONCLUSIONS: Cardiac troponin measured using a high-sensitivity assay is quantifiable in the majority of young pregnant women with 2% of individuals having concentration above the 99th percentile sex-specific threshold. Patients with pregnancy-induced hypertension or preeclampsia had higher cardiac troponin concentrations. Cardiac troponin was a strong independent predictor of pregnancy-induced hypertension or preeclampsia in pregnant and postnatal women. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:362 / 366
页数:5
相关论文
共 50 条
  • [21] Implications of High-Sensitivity Cardiac Troponin I in Cardiology Clinical Practice
    Khaw, C. S.
    Loretta, L. L. C.
    Fadhli, H. Amirul
    Azzlee, M.
    John, Y.
    Lim, H. S.
    Madzlan, N.
    Najihah, M. Z. Noor
    Nasyitah, Y.
    Shahira, R.
    Siow, Z. Y.
    Zailani, A. S. Mohd
    Hanim, M. A. Nor
    Khiew, N. Z.
    Cham, Y. L.
    Asri, S.
    Voon, C. Y.
    Oon, Y. Y.
    Koh, K. T.
    Ho, K. H.
    Tan, C. T.
    Fong, A. Y. Y.
    Ong, T. K.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 249 : S28 - S28
  • [22] An Approach to Investigating Discordant High-Sensitivity Cardiac Troponin I Results
    Kavsak, Peter A.
    Ainsworth, Craig
    Worster, Andrew
    CANADIAN JOURNAL OF CARDIOLOGY, 2021, 37 (08) : 1292 - 1293
  • [23] False positive high-sensitivity cardiac troponin I elevation in a newborn
    Domenis, Rossana
    Mauro, Isabella
    Paviotti, Giulia
    Biasotto, Alessia
    Curcio, Francesco
    D'Aurizio, Federica
    CLINICA CHIMICA ACTA, 2022, 534 : 185 - 187
  • [24] Cardiac Troponins and High-sensitivity Cardiac Troponin Assays
    Conrad, Michael J.
    Jarolim, Petr
    CLINICS IN LABORATORY MEDICINE, 2014, 34 (01) : 59 - +
  • [25] Hypertensive Disorders Of Pregnancy And Increased Levels Of Cardiac Troponin I After Delivery
    Kato, Takao
    Muta, Eri
    Inoko, Moriaki
    HYPERTENSION, 2021, 78
  • [26] High-Sensitivity Cardiac Troponin I Levels and Prediction of Heart Failure Results From the BiomarCaRE Consortium
    Yan, Isabell
    Boerschel, Christin S.
    Neumann, Johannes T.
    Spruenker, Ngoc A.
    Makarova, Nataliya
    Kontto, Jukka
    Kuulasmaa, Kari
    Salomaa, Veikko
    Magnussen, Christina
    Iacoviello, Licia
    Di Castelnuovo, Augusto
    Costanzo, Simona
    Linneberg, Allan
    Soderberg, Stefan
    Zeller, Tanja
    Ojeda-Echevarria, Francisco M.
    Blankenberg, Stefan
    Westermann, Dirk
    JACC-HEART FAILURE, 2020, 8 (05) : 401 - 411
  • [27] Differential effects of peripheral and central blood pressures on circulating levels of high-sensitivity cardiac troponin I
    Sugiura, T.
    Dohi, Y.
    Takase, H.
    Fujii, S.
    Ohte, N.
    EUROPEAN HEART JOURNAL, 2018, 39 : 116 - 116
  • [28] Application of High-Sensitivity Cardiac Troponin Values
    Ishii, Junnichi
    CIRCULATION JOURNAL, 2011, 75 (12) : 2753 - 2754
  • [29] Applying High-Sensitivity Cardiac Troponin T
    Glarner, Noemi
    Lopez-Ayala, Pedro
    Cakal, Hatice
    Grossenbacher, Mario
    Miro, Oscar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (18)
  • [30] High-sensitivity troponin: a barometer for cardiac health
    Lee, Kuan Ken
    Mills, Nicholas L.
    CARDIOVASCULAR RESEARCH, 2018, 114 (06) : E36 - E38