A Diagnostic Accuracy Study of Xpert®MTB/RIF in HIV-Positive Patients with High Clinical Suspicion of Pulmonary Tuberculosis in Lima, Peru

被引:28
|
作者
Carriquiry, Gabriela [1 ,2 ]
Otero, Larissa [2 ]
Gonzalez-Lagos, Elsa [1 ,2 ]
Zamudio, Carlos [2 ]
Sanchez, Eduardo [3 ]
Nabeta, Pamela [4 ]
Campos, Miguel [1 ,2 ]
Echevarria, Juan [1 ,2 ,5 ]
Seas, Carlos [1 ,2 ,5 ]
Gotuzzo, Eduardo [1 ,2 ,5 ]
机构
[1] Univ Peruana Cayetano Heredia, Fac Med Alberto Hurtado, Lima, Peru
[2] Univ Peruana Cayetano Heredia, Inst Med Trop Alexander von Humboldt, Lima, Peru
[3] Hosp Nacl Hipolito Unanue, Serv Enfermedades Infecciosas & Trop, Lima, Peru
[4] Fdn Innovat New Diagnost, Geneva, Switzerland
[5] Hosp Nacl Cayetano Heredia, Dept Enfermedades Infecciosas & Trop, Lima, Peru
来源
PLOS ONE | 2012年 / 7卷 / 09期
基金
美国国家卫生研究院;
关键词
XPERT MTB/RIF; MYCOBACTERIUM-TUBERCULOSIS; RIFAMPICIN RESISTANCE; ASSAY; IMPLEMENTATION; COUNTRIES; BURDEN; TB;
D O I
10.1371/journal.pone.0044626
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Diagnosis of pulmonary tuberculosis (TB) among human immunodeficiency virus (HIV) patients remains complex and demands easy to perform and accurate tests. Xpert (R) MTB/RIF (MTB/RIF) is a molecular TB diagnostic test which is rapid and convenient; the test requires minimal human resources and reports results within two hours. The majority of performance studies of MTB/RIF have been performed in high HIV burden settings, thus TB diagnostic studies among HIV patients in low HIV prevalence settings such as Peru are still needed. Methodology/Principal Findings: From April 2010 to May 2011, HIV-positive patients with high clinical suspicion of TB were enrolled from two tertiary hospitals in Lima, Peru. Detection of TB by MTB/RIF was compared to a composite reference standard Lowenstein-Jensen (LJ) and liquid culture. Detection of rifampicin resistance was compared to the LJ proportion method. We included 131 patients, the median CD4 cell count was 154.5 cells/mm(3) and 45 (34.4%) had TB. For TB detection among HIV patients, sensitivity of MTB/RIF was 97.8% (95% CI 88.4-99.6) (44/45); specificity was 97.7% (95% CI 91.9-99.4) (84/86); the positive predictive value was 95.7% (95% CI 85.5-98.8) (44/46); and the negative predictive value, 98.8% (95% CI 93.6-99.8) (84/85). MTB/RIF detected 13/14 smear-negative TB cases, outperforming smear microscopy [97.8% (44/45) vs. 68.9% (31/45); p = 0.0002]. For rifampicin resistance detection, sensitivity of MTB/RIF was 100% (95% CI 61.0-100.0) (6/6); specificity was 91.0% (95% CI 76.4-96.9) (30/33); the positive predictive value was 66.7% (95% CI 35.4-87.9) (6/9); and the negative predictive value was 100% (95% CI 88.7 -100.0) (30/30). Conclusions/Significance: In HIV patients in our population with a high clinical suspicion of TB, MTB/RIF performed well for TB diagnosis and outperformed smear microscopy.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Assessing the diagnostic accuracy of the Xpert MTB/RIF assay in detecting epididymal tuberculosis
    Pengju Liu
    Yuan Liu
    Yeqiang Wang
    Sida Hao
    Yong Qin
    European Journal of Clinical Microbiology & Infectious Diseases, 2022, 41 : 615 - 620
  • [22] Gene Xpert MTB/RIF assay in patients with clinical suspicion of tuberculous meningitis
    Rathod, Mukesh
    Qavi, Abdul
    Mittal, Vineeta
    Singh, Ajay Kumar
    Maurya, Pradeep Kumar
    Singh, Arvind
    Thacker, Anup
    Kulshreshtha, Dinkar
    NEUROLOGY ASIA, 2023, 28 (02) : 291 - 296
  • [23] Evaluation of the Xpert MTB/RIF Assay for the Diagnosis of Pulmonary Tuberculosis in a High HIV Prevalence Setting
    Theron, Grant
    Peter, Jonny
    van Zyl-Smit, Richard
    Mishra, Hridesh
    Streicher, Elizabeth
    Murray, Samuel
    Dawson, Rodney
    Whitelaw, Andrew
    Hoelscher, Michael
    Sharma, Surendra
    Pai, Madhukar
    Warren, Robin
    Dheda, Keertan
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 184 (01) : 132 - 140
  • [24] Performance of Xpert MTB/RIF, Xpert Ultra, and Abbott RealTime MTB for Diagnosis of Pulmonary Tuberculosis in a High-HIV-Burden Setting
    Berhanu, Rebecca H.
    David, Anura
    da Silva, Pedro
    Shearer, Kate
    Sanne, Ian
    Stevens, Wendy
    Scotte, Lesley
    JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (12)
  • [25] Xpert MTB/RIF Ultra versus Xpert MTB/RIF for the diagnosis of tuberculous meningitis: a prospective, randomised, diagnostic accuracy study
    Donovan, Joseph
    Do Dang Anh Thu
    Nguyen Hoan Phu
    Vu Thi Mong Dung
    Tran Phu Quang
    Ho Dang Trung Nghia
    Pham Kieu Nguyet Oanh
    Tran Bao Nhu
    Nguyen Van Vinh Chau
    Vu Thi Ngoc Ha
    Vu Thi Ty Hang
    Dong Huu Khanh Trinh
    Geskus, Ronald B.
    Le Van Tan
    Nguyen Thuy Thuong Thuong
    Thwaites, Guy E.
    LANCET INFECTIOUS DISEASES, 2020, 20 (03): : 299 - 307
  • [26] Diagnostic performance of the Xpert MTB/RIF assay in BAL fluid samples from patients under clinical suspicion of pulmonary tuberculosis: a tertiary care experience in a high-tuberculosis-burden area
    Xavier de Brito, Guilherme Machado
    Mafort, Thiago Thomaz
    Ribeiro-Alves, Marcelo
    Tavares Dos Reis, Larissa Vieira
    Leung, Janaina
    Leao, Robson Souza
    Rufino, Rogerio
    Rodrigues, Luciana Silva
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2021, 47 (02)
  • [27] Characteristics of Xpert MTB/RIF-Negative Patients With Pulmonary Tuberculosis
    Theron, Grant
    Peter, Jonny
    Dheda, Keertan
    CLINICAL INFECTIOUS DISEASES, 2012, 55 (03) : 472 - U195
  • [28] Diagnostic accuracy and effectiveness of the Xpert MTB/RIF assay for the diagnosis of HIV-associated lymph node tuberculosis
    Van Rie, A.
    Page-Shipp, L.
    Mellet, K.
    Scott, L.
    Mkhwnazi, M.
    Jong, E.
    Omar, T.
    Beylis, N.
    Stevens, W.
    Sanne, I.
    Menezes, C. N.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2013, 32 (11) : 1409 - 1415
  • [29] Diagnostic Accuracy Of Xpert Mtb/rif Assay In Stool Samples In Intrathoracic Childhood Tuberculosis
    Sinha, S.
    Menon, S.
    Sharma, S. K.
    Kabra, S. K.
    Pandey, R. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [30] Low diagnostic accuracy of Xpert MTB/RIF assay for extrapulmonary tuberculosis: A multicenter surveillance
    Mohammadreza Allahyartorkaman
    Mehdi Mirsaeidi
    Gholamreza Hamzehloo
    Sirus Amini
    Mona Zakiloo
    Mohammad Javad Nasiri
    Scientific Reports, 9