Comparison of optic nerve head parameters using Heidelberg Retina Tomograph 3 and spectral-domain optical coherence tomography

被引:16
|
作者
Sato, Shino [1 ]
Hirooka, Kazuyuki [1 ]
Baba, Tetsuya [1 ]
Shiraga, Fumio [1 ]
机构
[1] Kagawa Univ, Fac Med, Dept Ophthalmol, Miki, Kagawa 7610793, Japan
来源
关键词
Heidelberg Retina Tomograph; optic nerve head; optical coherence tomography; FIBER LAYER THICKNESS; SCANNING LASER OPHTHALMOSCOPY; STRATUS OCT; GLAUCOMATOUS EYES; AGREEMENT; REPRODUCIBILITY; TOPOGRAPHY;
D O I
10.1111/j.1442-9071.2012.02782.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To assess the agreement between the Heidelberg Retina Tomograph and Cirrus spectral-domain optical coherence tomography (Cirrus HD-OCT [Carl Zeiss Meditec, Dublin, CA, USA]) when measuring optic disc parameters. Design: Prospective, cross-sectional study. Participants: A total of 96 glaucoma patients and 21 normal subjects were analysed. Methods: Optic nerve head measurements, including disc area, rim area, cup-to-disc ratio and cup volume were obtained using both the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 (Heidelberg Engineering GmbH, Heidelberg, Germany). Main Outcome Measurements: BlandAltman plots were used to evaluate the agreement between each of the optic disc parameters. Results: Although Cirrus HD-OCT values were smaller than Heidelberg Retina Tomograph 3 values for the disc and rim areas, overall the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 measurements were highly correlated (r = 0.657 to 0.821). As compared with Heidelberg Retina Tomograph 3, disc and rim areas tended to be minimized by Cirrus HD-OCT, especially when there were large disc and rim areas, although there was no relationship between the discrepancy and the level of measurement of the cup-to-disc ratio. The optical coherence tomography overestimated the Heidelberg Retina Tomograph-determined cup volume, especially when there were large cup volumes. Conclusions: BlandAltman analyses revealed that with the exception of the cup-to-disc ratio, there was poor agreement between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3 morphometric measurements. In addition, with the exception of the cup-to-disc ratio, the optic nerve head measurements could not be directly compared between the Cirrus HD-OCT and Heidelberg Retina Tomograph 3.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [21] Descriptive information of topographic parameters computed at the optic nerve head with the Heidelberg Retina Tomograph
    Saruhan, A
    Orgül, S
    Koçak, I
    Prünte, C
    Flammer, J
    JOURNAL OF GLAUCOMA, 1998, 7 (06) : 420 - 429
  • [22] Precision of Optic Nerve Head and Retinal Nerve Fiber Layer Parameter Measurements by Spectral-domain Optical Coherence Tomography
    Schrems-Hoesl, Laura M.
    Schrems, Wolfgang A.
    Laemmer, Robert
    Kruse, Friedrich E.
    Mardin, Christian Y.
    JOURNAL OF GLAUCOMA, 2018, 27 (05) : 407 - 414
  • [23] Disagreement between Heidelberg Retina Tomograph and optical coherence tomography in assessing optic nerve head configuration of eyes with band atrophy and normal eyes
    Nagai-Kusuhara, A.
    Nakamura, M.
    Tatsumi, Y.
    Nakanishi, Y.
    Negi, A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (10) : 1382 - 1386
  • [24] Evaluation of the optic nerve head with the Heidelberg retina tomograph in diabetes mellitus
    Tekeli, Oya
    Turacli, M. Erol
    Atmaca, Leyla Suna
    Elhan, Atilla Halil
    OPHTHALMOLOGICA, 2008, 222 (03) : 168 - 172
  • [25] Comparison of swept-source and enhanced depth imaging spectral-domain optical coherence tomography in quantitative characterisation of the optic nerve head
    Li, Dejiao
    Taniguchi, Elise V.
    Cai, Sophie
    Paschalis, Eleftherios I.
    Wang, Haobing
    Miller, John B.
    Turalba, Angela V.
    Greenstein, Scott H.
    Brauner, Stacey
    Pasquale, Louis R.
    Shen, Lucy Q.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (03) : 299 - 304
  • [26] Spectral domain optical coherence tomography evaluation of the feline optic nerve and peripapillary retina
    Gomes, Filipe Espinheira
    Parry, Stephen
    Ledbetter, Eric
    VETERINARY OPHTHALMOLOGY, 2019, 22 (05) : 623 - 632
  • [27] Positional Independence of Optic Nerve Head and Retinal Nerve Fiber Layer Thickness Measurements With Spectral-Domain Optical Coherence Tomography
    Mansouri, Kaweh
    Liu, John H. K.
    Tafreshi, Ali
    Medeiros, Felipe A.
    Weinreb, Robert N.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (04) : 712 - 721
  • [28] Correlation between optic nerve head parameters and retinal nerve fibre layer thickness measured by spectral-domain optical coherence tomography in myopic eyes
    Hwang, Young H.
    Kim, Yong Y.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (07): : 713 - 720
  • [29] Optic nerve head parameters of high-definition optical coherence tomography and Heidelberg retina tomogram in perimetric and preperimetric glaucoma
    Begum, Viquar Unnisa
    Addepalli, Uday Kumar
    Senthil, Sirisha
    Garudadri, Chandra Sekhar
    Rao, Harsha Laxmana
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (04) : 277 - 284
  • [30] VARIABILITY OF OPTIC-NERVE HEAD PARAMETERS USING THE HEIDELBERG RETINAL TOMOGRAPH
    SHAFRANOV, G
    SCHUMER, RA
    LUSTGARTEN, JS
    PODOS, SM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1507 - 1507