A Novel Method for Automatic Identification of Motion Artifact Beats in ECG Recordings

被引:16
|
作者
Tu, Yuewen [1 ]
Fu, Xiuquan [1 ]
Li, Dingli [1 ]
Huang, Chao [1 ]
Tang, Yawei [1 ]
Ye, Shuming [1 ]
Chen, Hang [1 ]
机构
[1] Zhejiang Univ, Dept Biomed Engn, Bioanalyt Instruments Lab, Hangzhou 310003, Zhejiang, Peoples R China
关键词
Motion artifacts; ECG; Beat clustering; Fuzzy-logic; Higher order statistics; INDEPENDENT COMPONENT ANALYSIS; SIGNAL;
D O I
10.1007/s10439-012-0551-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a novel method for automatic identification of motion artifact beats in ECG recordings. The proposed method is based on the ECG complexes clustering, fuzzy logic and multi-parameters decision. Firstly, eight simulated datasets with different signal-to-noise ratio (SNR) were built for identification experiments. Results show that the identification sensitivity of our method is sensitive to SNR levels and acts like a low-pass filter that matches the cardiologists' recognition, while the Norm FP rate and PVB FP rate keep significantly low regardless of SNR. Furthermore, a simulated dataset including random durations of motion activities superimposed segments and two clinical datasets acquired from two different commercial recorders were adopted for the evaluation of accuracy and robustness. The overall identification results on these datasets were: sensitivity > 94.69%, Norm FP rate < 0.60% and PVB FP rate < 2.65%. All the results were obtained without any manual threshold adjustment according to the priori information, thus dissolving the drawbacks of previous published methods. Additionally, the total cost time of our method applied to 24 h recordings is less than 1 s, which is extremely suitable in the situation of magnanimity data in long-term ECG recordings.
引用
收藏
页码:1917 / 1928
页数:12
相关论文
共 50 条
  • [41] Evaluation of Artifact Subspace Reconstruction for Automatic Artifact Components Removal in Multi-Channel EEG Recordings
    Chang, Chi-Yuan
    Hsu, Sheng-Hsiou
    Pion-Tonachini, Luca
    Jung, Tzyy-Ping
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (04) : 1114 - 1121
  • [42] A Novel Method for Automatic Identification of Breathing State
    Niu, Jinglong
    Cai, Maolin
    Shi, Yan
    Ren, Shuai
    Xu, Weiqing
    Gao, Wei
    Luo, Zujin
    Reinhardt, Joseph M.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [43] A Novel Method for Automatic Identification of Breathing State
    Jinglong Niu
    Maolin Cai
    Yan Shi
    Shuai Ren
    Weiqing Xu
    Wei Gao
    Zujin Luo
    Joseph M. Reinhardt
    Scientific Reports, 9
  • [44] Flow motion artifact: Methods for automatic detection and suppression
    Verdenet, J
    Violand, H
    Pierali, C
    Bartholomot, B
    Cardot, J
    Kastler, BA
    RADIOLOGY, 1996, 201 : 817 - 817
  • [45] Support vector machine-based ECG beats automatic diagnosis system
    Liu, Zunxiong
    Shi, Fei
    Zheng, Shujuan
    Zhang, Xianlong
    Journal of Information and Computational Science, 2012, 9 (13): : 3805 - 3812
  • [46] An efficient method for ECG beat classification and correction of ectopic beats
    Mateo, J.
    Torres, A. M.
    Aparicio, A.
    Santos, J. L.
    COMPUTERS & ELECTRICAL ENGINEERING, 2016, 53 : 219 - 229
  • [47] Motion Artifact Suppression in the ECG Signal by Successive Modifications in Frequency and Time
    Subramaniam, Suba R.
    Ling, Bingo Wing-Kuen
    Georgakis, Apostolos
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 425 - 428
  • [48] A Non-Contact ECG Sensing System with Motion Artifact Equalization
    Gao, Shanqing
    Huang, Ding-Yu
    Fang, Wai-Chi
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 244 - 247
  • [49] Reliable Motion Artifact Detection for ECG Monitoring Systems with Dry Electrodes
    Ottenbacher, Joerg
    Kirst, Malte
    Jatoba, Luciana
    Huflejt, Michal
    Grossmann, Ulrich
    Stork, Wilhelm
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1695 - +
  • [50] Comparison of Reference Sensor Types and Position for Motion Artifact Removal in ECG
    Lilienthal, Jannis
    Dargie, Waltenegus
    29TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO 2021), 2021, : 1296 - 1300