CONSIDERATIONS FOR THE APPLICATION OF A MV HIGH SPEED GROUNDING SWITCH FOR ARC FLASH MITIGATION OF LV EQUIPMENT

被引:0
|
作者
Catlett, Raymond [1 ]
Lang, Mike [2 ]
Scala, Steve [3 ]
机构
[1] ABB Inc, 8 Driftwood, Collinsville, IL 62234 USA
[2] Mersen, 1135 Arya Dr, Roswell, GA 30076 USA
[3] Super Power Prod, POB 1188, Gotha, FL 34734 USA
关键词
Current limiting fuses; fuse interrupting time; high speed grounding switches; short circuit capacity (SCC); protective device coordination; arc flash mitigation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper expands on the work of a previous paper that presented the possibility of a significant reduction of incident energy on the secondary of medium voltage to low voltage (MV-LV) transformers with the combination of a high speed grounding switch (HSGS) and traditional MV current limiting (CL) E-Rated fuses. It was shown that when the HSGS is applied at a location between the E-rated fuse load terminals and the transformer's primary connection and controlled by relays on the LV side, incident energy can be reduced to less than 1.0 cal/cm(2). Whereas the first paper focused on the results from a high power test lab, this paper discusses issues related to its application on typical power systems and lessons learned from installations at several locations. Application considerations include a review of relay requirements, coordination of E-Rated fuses, requirements for resistance grounded systems, modeling in analysis software and field installation considerations.
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [21] Application of high speed double circular arc gears to turbo-blowers in refining equipment
    Li, Changchun
    Li, Yumin
    Hu, Changheng
    Dong, Xinnian
    Jixie goneheng Xuebao, 1988, 24 (04): : 19 - 22
  • [22] Considerations for Sending a Breaker Trip Command over Great Distances for the Purpose of Arc Flash Mitigation
    Proctor, Matt
    2014 67TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2014, : 313 - 317
  • [23] Installation and application considerations of arc resistant medium voltage control equipment
    Kay, John A.
    Sullivan, Paul B.
    Wactor, Michael
    INDUSTRY APPLICATIONS SOCIETY 54TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2007, : 49 - +
  • [24] Arc-Flash Hazard Calculations in LV and MV DC Systems-Part I: Short-Circuit Calculations
    Das, J. C.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (03) : 1687 - 1697
  • [25] Development of the High Speed Switch and its application
    Kishida, Y
    Koyama, K
    Sasao, H
    Maruyama, N
    Yamamoto, H
    CONFERENCE RECORD OF THE 1998 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3, 1998, : 2321 - 2328
  • [26] DC SWITCH WITH HIGH-SPEED OIL FLOW IN ARC REGION
    LAPSHIN, VE
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1986, 29 (02) : 411 - 415
  • [27] An application of photoconductive switch for high-speed testing
    Chihara, K
    Sekino, T
    Sasaki, K
    INTERNATIONAL TEST CONFERENCE 1996, PROCEEDINGS, 1996, : 669 - 676
  • [28] Phaselet-Based Arc Flash Relay Against Low Voltage Side Arcing Current Faults in MV-LV Power Transformers
    Saleh, S. A.
    Valdes, M. E.
    Sutherland, P. E.
    Haj-Ahmed, M.
    Zundel, E. W.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (06) : 7462 - 7474
  • [29] Analysis of electric arc flash protection principle and development application of its standard calibration equipment
    Chen X.
    Wei C.
    Liu Y.
    Li X.
    Liu G.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (14): : 160 - 165
  • [30] The application of flash-over switch in high energy fluence diode
    Zhang, Yongmin
    Tang, Junping
    Huang, Jianjun
    Qu, Aici
    Guan, Zhicheng
    Wang, Xinxin
    LASER AND PARTICLE BEAMS, 2008, 26 (02) : 213 - 216