Development of a sensitive method for simultaneous determination of fluticasone propionate and salmeterol in plasma samples by liquid chromatography-tandem mass spectrometry

被引:16
|
作者
Silvestro, Luigi [1 ]
Savu, Simona Rizea [1 ]
Savu, Simona Nicoleta [2 ]
Tudoroniu, Ariana [2 ]
Tarcomnicu, Isabela [2 ]
机构
[1] 3S Pharmacol Consultat & Res GmbH, D-27243 Harpstedt, Germany
[2] Pharma Serv Intl SRL, Bucharest 050853, Romania
关键词
fluticasone propionate; salmeterol; liquid chromatography; tandem mass-spectrometry; pharmacokinetics; BETA-AGONISTS; EQUINE URINE; INHALATION; LC/MS/MS; MS/MS;
D O I
10.1002/bmc.1708
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method for the fast simultaneous quantification of fluticasone propionate and salmeterol from plasma samples by liquid chromatographytandem mass spectrometry, with adequate sensitivity for pharmacokinetic applications, was developed and validated. The chromatographic separation and mass-spectrometric parameters were optimized for the retention and detection of the two compounds, despite quite different structures and properties. Two columns connected in series were used, cation-exchange (Zorbax 300-SCX, 5 cm x 2.1 mm, 5 mu m) and octadecyl (Discovery HSC18, 10 cm x 2.1 mm, 5 mu m). The mass-spectrometric interface was operated in negative electrospray ionization mode; high sensitivity and lesser matrix effects were obtained, permitting smaller consumption of plasma. The sample preparation was based on supported liquidliquid extraction in 96-well format plates that provided clean samples with a simplified procedure that was suitable for automation. The method was validated according to regulatory guidelines, by assessing lower limits of quantification, selectivity, linearity, accuracy, precision, extraction recoveries and matrix effects. A comparison with two other methods for the separate determination of fluticasone propionate and salmeterol in plasma samples, previously developed by our group, is presented. The statistical evaluation of the results obtained with the three methods on a set of unknown samples from treated patients demonstrated good correlation (R2 0.987 for fluticasone propionate and 0.967 for salmeterol). Copyright (c) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:627 / 635
页数:9
相关论文
共 50 条
  • [41] Development of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Sulfite in Food
    Robbins, Katherine S.
    Shah, Romina
    MacMahon, Shaun
    de Jager, Lowri S.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (21) : 5126 - 5132
  • [42] Highly sensitive determination of saquinavir in biological samples using liquid chromatography-tandem mass spectrometry
    Burhenne, J
    Riedel, KD
    Martin-Facklam, M
    Mikus, G
    Haefeli, WE
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (02): : 233 - 242
  • [43] Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma
    Ramakrishna, NVS
    Vishwottam, KN
    Manoj, S
    Koteshwara, M
    Wishu, S
    Varma, DP
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (10) : 751 - 760
  • [44] Sensitive Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Olanzapine in Human Urine
    Urdigere, Anil Kumar Rangachar
    Besagarahally, Bhasakra Laxmaiah
    Basavaiah, Kanakapura
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (05) : 1381 - 1387
  • [45] A sensitive multiresidue method for the determination of pesticides in marijuana by liquid chromatography-tandem mass spectrometry
    Daniel, Daniela
    Lopes, Fernando Silva
    do Lago, Claudimir Lucio
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1603 : 231 - 239
  • [46] SENSITIVE METHOD FOR DETERMINATION OF PIPLARTINE, AN ALKALOID AMIDE FROM Piper SPECIES, IN RAT PLASMA SAMPLES BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Bezerra, Daniel P.
    Pessoa, Claudia
    Moraes, Manoel O.
    Costa-Lotufo, Leticia V.
    Gouvea, Dayana Rubio
    Polisel Jabor, Valquiria A.
    Lopes, Norberto Peporine
    Borges, Keyller Bastos
    Lima, Mary Anne S.
    Silveira, Edilberto R.
    QUIMICA NOVA, 2012, 35 (03): : 460 - 465
  • [47] Determination of corticosteroids in tissue samples by liquid chromatography-tandem mass spectrometry
    Rönquist-Nii, Y
    Edlund, PO
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (02) : 341 - 350
  • [48] Development and Validation of a Sensitive Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Naringin and Its Metabolite, Naringenin, in Human Plasma
    Xiong, Xin
    Jiang, Junjie
    Duan, Jingli
    Xie, Yanming
    Wang, Jiannong
    Zhai, Suodi
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (07) : 654 - 660
  • [49] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of ε-acetamidocaproic acid in rat plasma
    Kim T.H.
    Choi Y.S.
    Choi Y.H.
    Kim Y.G.
    Toxicological Research, 2013, 29 (3) : 203 - 209
  • [50] Development and validation of a method for quantitative determination of valsartan in human plasma by liquid chromatography-tandem mass spectrometry
    Koseki, Nozomu
    Kawashita, Hiroto
    Hara, Hisanori
    Niina, Miyuki
    Tanaka, Makoto
    Kawai, Ryosei
    Nagae, Yusuke
    Masuda, Naoki
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) : 1769 - 1774