Seismic analysis of nailed vertical excavation using pseudo-dynamic approach

被引:15
|
作者
Sarangi, Piyush [1 ]
Ghosh, Priyanka [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Kanpur 208016, Uttar Pradesh, India
关键词
earthquake; factor of safety; pseudo-dynamic approach; soil nailing; vertical excavation; EARTH PRESSURE; STABILITY; CAPACITY;
D O I
10.1007/s11803-016-0353-x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An attempt has been made to study the behavior of nailed vertical excavations in medium dense to dense cohesionless soil under seismic conditions using a pseudo-dynamic approach. The effect of several parameters such as angle of internal friction of soil (phi), horizontal (k(h)) and vertical (k(v)) earthquake acceleration coefficients, amplification factor (f(a)), length of nails (L), angle of nail inclination (alpha) and vertical spacing of nails (S-v) on the stability of nailed vertical excavations has been explored. The limit equilibrium method along with a planar failure surface is used to derive the formulation involved with the pseudo-dynamic approach, considering axial pullout of the installed nails. A comparison of the pseudo-static and pseudo-dynamic approaches has been established in order to explore the effectiveness of the pseudo-dynamic approach over pseudo-static analysis, since most of the seismic stability studies on nailed vertical excavations are based on the latter. The results are expressed in terms of the global factor of safety (FOS). Seismic stability, i.e., the FOS of nailed vertical excavations is found to decrease with increase in the horizontal and vertical earthquake forces. The present values of FOS are compared with those available in the literature.
引用
收藏
页码:621 / 631
页数:11
相关论文
共 50 条
  • [41] A Pseudo-dynamic Approach for Seismic Stability Analysis of Rock Slopes in Hoek-Brown Media
    Wang, Bowen
    Li, Tingting
    Sun, Zhibin
    Li, Yongxin
    Hou, Chaoqun
    GEOTECHNICAL AND GEOLOGICAL ENGINEERING, 2022, 40 (07) : 3561 - 3577
  • [42] Seismic passive earth resistance using modified pseudo-dynamic method
    Anindya Pain
    Deepankar Choudhury
    S.K.Bhattacharyya
    Earthquake Engineering and Engineering Vibration, 2017, 16 (02) : 263 - 274
  • [43] Seismic passive earth resistance using modified pseudo-dynamic method
    Anindya Pain
    Deepankar Choudhury
    S. K. Bhattacharyya
    Earthquake Engineering and Engineering Vibration, 2017, 16 : 263 - 274
  • [44] Seismic stability of anchored rock slope using pseudo-dynamic method
    Ruan Xiao-bo
    Sun Shu-lin
    Liu Wen-liang
    ROCK AND SOIL MECHANICS, 2013, 34 : 293 - 300
  • [45] Seismic passive earth resistance using modified pseudo-dynamic method
    Pain, Anindya
    Choudhury, Deepankar
    Bhattacharyya, S. K.
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2017, 16 (02) : 263 - 274
  • [46] The dynamic analysis of piping systems using pseudo-dynamic techniques
    de Melo, FJMQ
    Carneiro, JAO
    Lopes, HR
    Rodrigues, JFD
    Gomes, JFS
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2001, 36 (05): : 441 - 451
  • [47] Probabilistic seismic stability of three-dimensional slopes by pseudo-dynamic approach
    Pan Qiu-jing
    Qu Xing-ru
    Wang Xiang
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2019, 26 (07) : 1687 - 1695
  • [48] Pseudo-dynamic approach of seismic active earth pressure behind retaining wall
    Choudhury, Deepankar
    Nimbalkar, Sanjay
    GEOTECHNICAL AND GEOLOGICAL ENGINEERING, 2006, 24 (05) : 1103 - 1113
  • [49] Seismic Bearing Capacity Factors for Shallow Strip Footings by Pseudo-Dynamic Approach
    Priyanka, Ghosh
    Deepankar, Choudhury
    DISASTER ADVANCES, 2011, 4 (03): : 34 - 42
  • [50] Seismic active earth pressure behind a nonvertical retaining wall using pseudo-dynamic analysis
    Ghosh, Priyanka
    CANADIAN GEOTECHNICAL JOURNAL, 2008, 45 (01) : 117 - 123