Preconcentration and voltammetric study of nicergoline at a carbon paste electrode

被引:7
|
作者
Radi, A [1 ]
机构
[1] Mansoura Univ, Dept Chem, Fac Sci, Demiatta 34517, Egypt
关键词
nicergoline; stripping voltammetry; carbon paste electrode;
D O I
10.1007/s006040050041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical oxidation of nicergoline is investigated using cyclic and differential pulse voltammetry at a carbon paste electrode. For the determination of nicergoline an adsorptive stripping procedure is proposed. The response is characterized with respect to pH, ionic strength, preconcentration time, accumulation potential, nicergoline concentration, reproducibility and other variables. By differential pulse voltammetry at a carbon paste electrode and pH 8.0, a linear calibration in the range 5 x 10(-8) M to 1x10(-7) hi and a detection limit of 1x10(-8) M are obtained. The preconcentration medium-exchange approach was used for a selective determination of nicergoline in urine. For dilute urine samples a detection limit of 5x10(-8) M is obtained after 3 min of accumulation and medium-exchange. The procedure also is applied for the determination of nicergoline in dosage form.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 50 条
  • [31] Electrocatalytic Oxidation of Dopamine on Acrylamide Modified Carbon Paste Electrode: A Voltammetric Study
    Shankar, S. Sharath
    Swamy, B. E. Kumara
    Pandurangachar, M.
    Chandra, Umesh
    Chandrashekar, B. N.
    Manjunatha, J. G.
    Sherigara, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (07): : 944 - 954
  • [32] Poly (vanillin) modified carbon paste electrode for the determination of adrenaline: A voltammetric study
    Madhuchandra H.D.
    Swamy B.E.K.
    Materials Science for Energy Technologies, 2019, 2 (03) : 697 - 702
  • [33] Preconcentration and Electroanalysis of Copper at Zeolite Modified Carbon Paste Electrode
    Mazloum-Ardakani, Mohammad
    Akrami, Z.
    Kazemian, H.
    Zare, Hamid. R.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (02): : 308 - 319
  • [34] Anodic voltammetric assay of the herbicide Metamitron on a carbon paste electrode
    A. Arranz
    M. F. Villalba
    S. F. de Betoño
    J. M. Moreda
    J. F. Arranz
    Fresenius' Journal of Analytical Chemistry, 1997, 357 : 768 - 772
  • [36] Voltammetric determination of selected aminoquinolines using carbon paste electrode
    Zima, J
    Stoica, AI
    Zítová, A
    Barek, J
    ELECTROANALYSIS, 2006, 18 (02) : 158 - 162
  • [37] VOLTAMMETRIC DETERMINATION OF NITRATE WITH A MODIFIED CARBON-PASTE ELECTRODE
    NEUHOLD, C
    KALCHER, K
    DIEWALD, W
    CAI, XH
    RABER, G
    ELECTROANALYSIS, 1994, 6 (03) : 227 - 236
  • [38] Voltammetric determination of bisphenol A using modified carbon paste electrode
    Jahani, Peyman Mohammadzadeh
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024,
  • [39] Voltammetric determination of lactate dehydrogenase using a carbon paste electrode
    Tarmure, C
    Sandulescu, R
    Ionescu, C
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (02) : 355 - 361
  • [40] Adsorptive voltammetric determination of cisapride on carbon nanotubes paste electrode
    Zheng Li
    Song Jun-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 1018 - 1020