Solid Dielectric Transmission Lines for Pulsed Power

被引:0
|
作者
Domonkos, M. T. [1 ]
Heidger, S. [1 ]
Brown, D. [2 ]
Cavazos, T. [2 ]
Devoe, A. [3 ]
Dogan, F. [4 ]
Gale, D. [2 ]
O'Loughlin, J. [1 ]
Parker, J. [2 ]
Sandoval, D. [2 ]
Slenes, K. [5 ]
Sommars, W. [2 ]
Watrous, J. [6 ]
机构
[1] Air Force Res Lab, Directed Energy Directorate, Kirtland AFB, NM USA
[2] SAIC, Albuquerque, NM USA
[3] Presidio Components, San Diego, CA USA
[4] Missouri Inst Sci & Technol, Rolla, MO USA
[5] TPL Inc, Albuquerque, NM USA
[6] NumerEx, LLC, Albuquerque, NM USA
关键词
solid dielectric; transmission line; pulsed power;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper documents recent work developing solid dielectric transmission lines for sub-microsecond, 100 kV class compact pulsed power systems. Polymer-ceramic nanocomposite materials have demonstrated sub-microsecond discharge capability in parallel plate capacitors and transmission lines [1, 2]. With a dielectric constant of approximately 50, the propagation velocity is 2.5 cm/ns, necessitating lines of several meters length to achieve > 100 ns pulse lengths. By folding the line in a fashion analogous to ceramic multilayer capacitors, the physical length of the line can be significantly shorter than the electrical length. We present the results of an experimental effort to develop a folded transmission line using a polymer-ceramic nanocomposite dielectric. The pulse length was somewhat shorter than expected based on a simple calculation using the geometry and the dielectric constant. Fully 3-D electromagnetic calculations were used to examine the role of the edges in curtailing the pulse length. Dielectric breakdown in this device occurred below the electric field threshold demonstrated in the prior work [1]. Improvements in the large scale fabrication of TiO2 beginning with nanoscale grains have opened the possibility for producing single layer high voltage devices. Given a dielectric constant approaching 140, transmission lines using nano-TiO2 can be considerably shorter than with other materials. Relatively thick, flat sheets of TiO2 have been fabricated for testing up to 50 kV. Several transmission lines, employing a serpentine electrode geometry, have been manufactured and tested. Testing up to several 10's of kV has confirmed the operation of the lines according to the design. As expected, the triple point between the TiO2, electrode, and insulating medium has proven difficult to manage for high voltage operation. Several techniques to mitigate the effects of the triple point, including resistive grading at the edges of the electrodes, are discussed. Fully 3-D electromagnetic modeling is used to examine the effects of electrode geometry and composition on the performance of the lines.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 50 条
  • [41] Power supply instrumentation for pulsed dielectric barrier discharges
    Quiroz Velazquez, V. E.
    Lopez Callejas, R.
    Rodriguez Mendez, B. G.
    Pena Eguiluz, R.
    de la Piedad Beneitez, A.
    Munoz Castro, E.
    Barocio, S. R.
    Mercado Cabrera, A.
    Valencia Alvarado, R.
    14TH LATIN AMERICAN WORKSHOP ON PLASMA PHYSICS (LAWPP 2011), 2012, 370
  • [42] A Dielectric Rod Antenna Driven by a Pulsed Power System
    Petrella, R. A.
    Schoenbach, K. H.
    Xiao, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (04) : 2157 - 2163
  • [43] AN EVALUATION OF DIELECTRIC MATERIALS FOR USE IN PULSED POWER DEVICES
    Leask, P. J.
    Ibbotson, R. A.
    Evans, S. J.
    2009 IEEE PULSED POWER CONFERENCE, VOLS 1 AND 2, 2009, : 435 - 440
  • [44] DIELECTRIC LIQUIDS FOR POSSIBLE USE IN PULSED POWER SWITCHES
    CHRISTOPHOROU, LG
    APPLIED PHYSICS LETTERS, 1989, 55 (10) : 948 - 950
  • [45] Solid-state pulsed power systems
    Gaudreau, MPJ
    Casey, J
    Hawkey, T
    Mulvaney, JM
    Kempkes, MA
    CONFERENCE RECORD OF THE 1998 TWENTY-THIRD INTERNATIONAL POWER MODULATOR SYMPOSIUM, 1998, : 160 - 163
  • [46] A Dielectric Lens Rectenna for Wireless Power Transmission
    Hobballah, Abdel-Hadi
    Negrier, Romain
    Lalande, Michele
    2021 51ST EUROPEAN MICROWAVE CONFERENCE (EUMC), 2021, : 672 - 675
  • [47] A Criticality Assessment Method for Power Transmission Lines in Power System
    Liu, Wenying
    Liang, Cai
    ADVANCED RESEARCH IN MATERIAL SCIENCE AND MECHANICAL ENGINEERING, PTS 1 AND 2, 2014, 446-447 : 817 - +
  • [48] Analysis of the conditions of power lines connection in transmission power system
    Eleschova, Zaneta
    Belan, Anton
    PROCEEDINGS OF THE 10TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2009, 2009, : 219 - 224
  • [49] HALF-WAVELENGTH POWER TRANSMISSION LINES
    HUBERT, FJ
    GENT, MR
    IEEE SPECTRUM, 1965, 2 (01) : 87 - &
  • [50] Design of the Linebot For Power Transmission Lines Inspection
    Wang, Chengjiang
    Ye, Linji
    Zhao, Wang
    Wu, Gaolin
    Chen, Yongquan
    Qian, Huihuan
    Xu, Yangsheng
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2013, : 2593 - 2598