Ionic Liquid Matrix-Enhanced Secondary Ion Mass Spectrometry: The Role of Proton Transfer

被引:21
|
作者
Dertinger, Jennifer J. [1 ]
Walker, Amy V. [1 ]
机构
[1] Univ Texas Dallas, Dept Mat Sci & Engn, Richardson, TX 75080 USA
基金
美国国家科学基金会;
关键词
SIMS; MALDI; Ionic liquid matrices; FAST-ATOM-BOMBARDMENT; MALDI-MS; PHOSPHOLIPIDS;
D O I
10.1007/s13361-012-0568-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Room temperature ionic liquids (ILs) are effective matrices in secondary ion mass spectrometry (SIMS) and matrix assisted laser desorption ionization (MALDI). In this paper, we examine the role of proton transfer in the mechanism of secondary ion enhancement using IL matrices in SIMS. We employ hydrogenated and deuterated 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) as analytes to investigate the origin of proton transfer. The data indicate that protons from the IL anion transfer to the analyte in solution leading to an increase in the secondary ion intensity of the protonated molecular ion. The chemical identity of the matrix cation also affects analyte signal intensities. Using deuterated DPPC we observe that protons (deuterium) from the DPPC tail group react with the cation of the IL liquid leading to an increase in (cation + D)(+) ion intensities. Further, the data suggest that the transfer kinetics of deuterium (hydrogen) is correlated with the secondary ion enhancements observed. The highest secondary ion enhancements are observed for the least sterically hindered cation. Neither the proton affinity nor the pK(a) of the IL cation have a large effect on the analyte ion intensities, suggesting that steric factors are important in determining the efficacy of IL matrices for a given analyte.
引用
收藏
页码:348 / 355
页数:8
相关论文
共 50 条
  • [31] Matrix-enhanced nanostructure initiator mass spectrometry (ME-NIMS) for small molecule detection and imaging
    Moening, Tara N.
    Brown, Victoria L.
    He, Lin
    Analytical Methods, 2016, 8 (46) : 8234 - 8240
  • [32] Improvement of biomolecular analysis in thin films using in situ matrix enhanced secondary ion mass spectrometry
    Moshkunov, Konstantin
    Tomasetti, Benjamin
    Daphnis, Thomas
    Delmez, Vincent
    Vanvarenberg, Kevin
    Preat, Veronique
    Lorenz, Matthias
    Quanico, Jusal
    Baggerman, Geert
    Lemiere, Filip
    Dupont, Christine
    Delcorte, Arnaud
    ANALYST, 2021, 146 (21) : 6506 - 6519
  • [33] Secondary ion mass spectrometry investigation of liquid gallium recovery
    Zakourdaev, IV
    Tolstogouzov, AB
    Gnido, VF
    Kitaeva, TI
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (19) : 1356 - 1358
  • [34] THE USE OF 2-HYDROXYETHYL DISULFIDE AS A MATRIX IN LIQUID SECONDARY-ION MASS-SPECTROMETRY
    KENNY, PTM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (05) : 156 - 158
  • [35] MATRIX SELECTION FOR LIQUID SECONDARY-ION AND FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY
    DEPAUW, E
    METHODS IN ENZYMOLOGY, 1990, 193 : 201 - 214
  • [36] SECONDARY ION MASS-SPECTROMETRY WITH CESIUM ION PRIMARY BEAM AND LIQUID TARGET MATRIX FOR ANALYSIS OF BIOORGANIC COMPOUNDS
    ABERTH, W
    STRAUB, KM
    BURLINGAME, AL
    ANALYTICAL CHEMISTRY, 1982, 54 (12) : 2029 - 2034
  • [37] NEGATIVE GOLD ION GUN FOR LIQUID SECONDARY ION MASS-SPECTROMETRY
    MCEWEN, CN
    HASS, JR
    ANALYTICAL CHEMISTRY, 1985, 57 (04) : 890 - 892
  • [38] LIQUID METAL SOURCES IN ION MICROSCOPY AND SECONDARY ION MASS SPECTROMETRY.
    Mair, G.L.R.
    Mulvey, T.
    1600, (0v):
  • [39] Ion-pair cationization process in liquid secondary ion mass spectrometry
    Georgia Inst of Technology, Atlanta, United States
    Appl Spectrosc, 4 (537-540):
  • [40] Ion-pair cationization process in liquid secondary ion mass spectrometry
    Mohan, KR
    Wilson, MMN
    Haseltine, J
    Busch, KL
    APPLIED SPECTROSCOPY, 1996, 50 (04) : 537 - 540