SURGICAL TREATMENT OF UNSTABLE DISTAL RADIUS FRACTURES WITH LOCKING VOLAR PLATES: COMPARISON BETWEEN RADIOGRAPHIC OUTCOMES AND FUNCTIONAL RESULTS

被引:0
|
作者
Casale, V. [1 ]
Agati, G. [1 ]
Masse, A. [1 ]
Schiro, M. [1 ]
Violante, E. [1 ]
Drogo, N. [1 ]
D'amelio, A. [1 ]
机构
[1] Azienda Osped Univ San Luigi Gonzaga, Struttura Complessa Dipartimento Univ Ortopedia &, Turin, Italy
关键词
Radius fractures; Volar plate; Wrist joint; COLLES FRACTURE; DORSAL; FIXATION; COMPRESSION; PALMAR; MODEL; END;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim. The purpose of this study was to correlate the clinical results obtained with the radiographic findings after surgery for internal fixation of fractures of the wrist joint. We wanted to seek to restore the anatomical features with particular precision to the most influential ones on functional recovery. Methods. Fifty patients with articular wrist fractures (AO classification Foundation: A2, A3, B3, C2 and C3) treated with internal fixation with a volar plate with angular stability, operated between 2008 and 2011 at the San Luigi Gonzaga AOU Orbassano, between 19 and 85 years old. We used Aptus Radius (Medartis(R)) volar plates. Mean postoperative immobilization was 18 days. Mean follow-up was 23 months. Patients were all clinically evaluated using the Mayo Wrist Score. Radiographically we calculated the distal radial volar tilt angle, the radial deviation angle, the radial length and the ulnar variance. Results. Clinically, the results were satisfactory. The ideal immobilization time for a better recovery was from 14 to 21 days. Among the associated fractures of the ulnar styloid, patients who were not treated with surgery functionally recovered less than those who underwent additional surgical treatment. Conclusion. A careful reduction of distal radius fracture and a stable osteosynthesis are the first goal of surgical treatment of wrist fractures. Restoring the anatomical integrity of DRUJ and reduction with synthesis of eventual fracture of the ulnar styloid are also important goals to search for the best functional recovery.
引用
收藏
页码:293 / 303
页数:11
相关论文
共 50 条
  • [31] Osteosynthesis with long volar locking plates for metaphyseal-diaphyseal fractures of the distal radius
    Gogna, Paritosh
    Selhi, Harpal Singh
    Singla, Rohit
    Mohindra, Mukul
    Batra, Amit
    Mukhopadhyay, Reetadyuti
    Rohilla, Rajesh
    Yadav, Umesh
    CHINESE JOURNAL OF TRAUMATOLOGY, 2013, 16 (06) : 339 - 343
  • [32] Ulnar Styloid Fracture in Distal Radius Fractures Managed with Volar Locking Plates: To Fix or Not?
    Gogna, Paritosh
    Selhi, Harpal Singh
    Mohindra, Mukul
    Thora, Ankit
    Yamin, Mohammad
    JOURNAL OF HAND AND MICROSURGERY, 2014, 6 (02) : 53 - 58
  • [33] Flexor tendon complications in distal radius fractures treated with volar rim locking plates
    Fardellas, A.
    Vernet, P.
    Facca, S.
    Liverneaux, P.
    HAND SURGERY & REHABILITATION, 2020, 39 (06): : 511 - 515
  • [34] Outcomes of Primary Volar Locking Plate Fixation of Open Distal Radius Fractures
    Joo, Min Su
    Kang, Hong Je
    Yu, Hyun Kyu
    Lee, Jae Sung
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2022, 27 (03): : 517 - 523
  • [35] Functional and Radiographic Outcomes for Distal Radius Fractures Treated with Volar-Locked Plates and Percutaneous K-Wires: A Comparative Study
    Egiazaryan, Karen A.
    Maximov, Boris, I
    Askerov, Artur A.
    Vedernikov, Nikolay N.
    Matvienko, Maksim, I
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2021, 27 (04): : 31 - 41
  • [36] Volar Locking Plates Versus External Fixation and Adjuvant Pin Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study
    Williksen, John H.
    Frihagen, Frede
    Hellund, Johan C.
    Kvernmo, Hebe D.
    Husby, Torstein
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (08): : 1469 - 1476
  • [37] Outcomes of Volar Plating Distal Radius Fractures Based on Surgical Timing
    Campbell, Benjamin R.
    Reyes, Ariana A.
    Neustein, Thomas M.
    Miller, Andrew J.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2025, 20 (02): : 252 - 257
  • [38] Design of distal radius volar locking plates. Anatomical, surgical and biomechanical aspects
    Wich, M.
    Sixto, R.
    Spranger, N.
    UNFALLCHIRURG, 2016, 119 (09): : 742 - 746
  • [39] Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures
    Usta, Emirhan
    Akpolat, Ahmet O.
    Kahraman, Ahmet N.
    Kara, Adnan
    Oc, Yunus
    Kilinc, Bekir E.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [40] Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures
    Mugnai, Raffaele
    Tarallo, Luigi
    Capra, Francesco
    Catani, Fabio
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (06) : 877 - 882