Electrochemical determination of para-nitrophenol at apatite-modified carbon paste electrode: Application in river water samples

被引:158
|
作者
El Mhammedi, M. A. [1 ]
Achak, M. [2 ]
Bakasse, M. [3 ]
Chtaini, A. [1 ]
机构
[1] Univ Sultan Moulay Slimane, Equipe Electrochim & Mat Inorgan, Fac Sci & Tech, Beni Mellal, Morocco
[2] Univ Cadi Ayyad, Fac Sci Semlalia, Lab Hydrobiol & Algol, Marrakech, Morocco
[3] Univ Chouaib Doukkali, Fac Sci, Equipe Anal Micropolluants Organ, El Jadida, Morocco
关键词
Carbon paste electrode; Hydroxyapatite; para-Nitrophenol; Square wave voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; VOLTAMMETRIC DETERMINATION; P-NITROPHENOL; 4-NITROPHENOL; PHENOLS;
D O I
10.1016/j.jhazmat.2008.06.126
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The behavior of a modified carbon paste electrode (CPE) for para-nitrophenol detection by cyclic and square wave voltammetry (SWV) was studied. The electrode was built by incorporating the hydroxyapatite (HAP) to carbon paste. The overall analysis involved a two-step procedure: an accumulation step at open circuit, followed by medium exchange to a pure electrolyte solution for the voltammetric quantification. During the preconcentration step, para-nitrophenol was adsorbed onto hydroxyapatite surface. The influence of various experimental parameters on the HAP-CPE response was investigated (i.e. pH, carbon paste composition, accumulation time). Under the optimized conditions, the reduction peak shows that the peak height was found to be directly proportional to the para-nitrophenol concentration in the range comprised between 2 x 10(-7) mol L-1 and 1 x 10(-4) mol L-1. With this, it was possible to determine detection limit (DL), which resulted in 8 x 10(-9) mol L-1 for peak 1. The proposed electrode (HAP-CPE) presented good repeatability, evaluated in term of relative standard deviation (R.S.D. = 2.87%) for n = 7 and was applied for para-nitrophenol determination in water samples. The average recovery for these samples was 86.2%. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 50 条
  • [21] Electrochemical determination of adenosine by natural phosphate modified carbon paste electrode: Analytical application in serum
    Smaini, M. A.
    Smaini, I
    Ennachete, M.
    Laghlimi, C.
    Saadane, H.
    Moutcine, A.
    Chtaini, A.
    SENSING AND BIO-SENSING RESEARCH, 2019, 23
  • [22] Voltammetric determination of 2-nitrophenol at a bentonite-modified carbon paste electrode
    Rodriguez, IN
    Zamora, MB
    Salvador, JMB
    Leyva, JAM
    HernandezArtiga, MP
    deCisneros, JLHH
    MIKROCHIMICA ACTA, 1997, 126 (1-2) : 87 - 92
  • [23] Voltammetric determination of 2-nitrophenol at a bentonite-modified carbon paste electrode
    Ignacio Naranjo Rodriguez
    Manuel Barea Zamora
    Juan M. Barberá Salvador
    Juan A Muñoz Leyva
    María P. Hernandez-Artiga
    Jose L. Hidalgo Hidalgo de Cisneros
    Microchimica Acta, 1997, 126 : 87 - 92
  • [25] A novel high selective and sensitive para-nitrophenol voltammetric sensor, based on a molecularly imprinted polymer-carbon paste electrode
    Alizadeh, Taher
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    Zare, Mashallah
    Zeraatkar, Ali
    TALANTA, 2009, 79 (05) : 1197 - 1203
  • [26] Carbon Paste Electrode Modified with Biochar for Sensitive Electrochemical Determination of Paraquat
    Kalinke, Cristiane
    Mangrich, Antonio S.
    Marcolino-Junior, Luiz H.
    Bergamini, Marcio F.
    ELECTROANALYSIS, 2016, 28 (04) : 764 - 769
  • [27] Electrocatalytic determination of sulfite using a modified carbon nanotubes paste electrode: application for determination of sulfite in real samples
    Karimi-Maleh, Hassan
    Ensafi, Ali A.
    Beitollahi, Hadi
    Nasiri, Vahid
    Khalilzadeh, Mohammad A.
    Biparva, Pourya
    IONICS, 2012, 18 (07) : 687 - 694
  • [28] Electrocatalytic determination of sulfite using a modified carbon nanotubes paste electrode: application for determination of sulfite in real samples
    Hassan Karimi-Maleh
    Ali A. Ensafi
    Hadi Beitollahi
    Vahid Nasiri
    Mohammad A. Khalilzadeh
    Pourya Biparva
    Ionics, 2012, 18 : 687 - 694
  • [29] A New Electrochemical Approach for the Determination of Phenylhydrazine in Water and Wastewater Samples using Amplified Carbon Paste Electrode
    Montazarolmahdi, Maliheh
    Masrournia, Mahboubeh
    Nezhadali, Azizollah
    CHEMICAL METHODOLOGIES, 2020, 4 (06): : 732 - 742
  • [30] Application of Carbon Paste Electrode Modified with Carbon Nanofibres/Polyaniline/Platinum Nanoparticles as an Electrochemical Sensor for the Determination of Bezafibrate
    Rajpurohit, Anuja S.
    Punde, Ninad S.
    Rawool, Chaitali R.
    Srivastava, Ashwini K.
    ELECTROANALYSIS, 2018, 30 (03) : 571 - 582