The Image Gently Pediatric Digital Radiography Safety Checklist: Tools for Improving Pediatric Radiography

被引:16
|
作者
John, Susan D. [1 ,2 ]
Moore, Quentin T. [3 ]
Herrmann, Tracy [4 ]
Don, Steven [5 ,6 ,7 ]
Powers, Kevin [8 ]
Smith, Susan N. [9 ]
Morrison, Greg [8 ]
Charkot, Ellen [10 ]
Mills, Thalia T. [11 ]
Rutz, Lois [12 ]
Goske, Marilyn J. [9 ]
机构
[1] Univ Texas Med Sch, Dept Diagnost & Intervent Imaging, Houston, TX 77030 USA
[2] Univ Texas Med Sch, Dept Pediat, Houston, TX 77030 USA
[3] Mercy Coll Ohio, Toledo, OH USA
[4] Univ Cincinnati, Blue Ash Coll, Cincinnati, OH USA
[5] Washington Univ, Med Ctr, Mallinckrodt Inst Radiol, Elect Radiol Lab, St Louis, MO 63110 USA
[6] St Louis Childrens Hosp, St Louis, MO 63178 USA
[7] Washington Univ, Sch Med, St Louis, MO USA
[8] Amer Soc Radiol Technologists, Albuquerque, NM USA
[9] Cincinnati Childrens Hosp Med Ctr, Cincinnati, OH 45229 USA
[10] Hosp Sick Children, Toronto, ON M5G 1X8, Canada
[11] US FDA, Ctr Devices & Radiol Hlth, Silver Spring, MD USA
[12] GAMMEX Inc, Middleton, WI USA
关键词
Digital radiography; radiation dose; quality; safety; children; checklist; SYSTEM;
D O I
10.1016/j.jacr.2013.02.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Transition from film-screen to digital radiography requires changes in radiographic technique and workflow processes to ensure that the minimum radiation exposure is used while maintaining diagnostic image quality. Checklists have been demonstrated to be useful tools for decreasing errors and improving safety in several areas, including commercial aviation and surgical procedures. The Image Gently campaign, through a competitive grant from the FDA, developed a checklist for technologists to use during the performance of digital radiography in pediatric patients. The checklist outlines the critical steps in digital radiography workflow, with an emphasis on steps that affect radiation exposure and image quality. The checklist and its accompanying implementation manual and practice quality improvement project are open source and downloadable at www.imagegently.org. The authors describe the process of developing and testing the checklist and offer suggestions for using the checklist to minimize radiation exposure to children during radiography.
引用
收藏
页码:781 / 788
页数:8
相关论文
共 50 条
  • [21] OPTIMIZING IMAGE QUALITY, RADIATION DOSAGE TO THE PATIENT AND TO THE DETECTOR IN PEDIATRIC CHEST RADIOGRAPHY: A PHANTOM STUDY OF A PORTABLE DIGITAL RADIOGRAPHY SYSTEM
    Shahgeldi, Kaveh
    Sjoberg, Tommy
    Nordstrom, Jonny
    Lesanu, Radu
    Svahn, Tony Martin
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (04) : 414 - 420
  • [22] Improving pediatric radiation dose management using Agfa digital radiography DICOM header information
    Juste, B.
    Villaescusa, N.
    Granero, D.
    Verdu, G.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4457 - +
  • [23] Radiography in the Evaluation of Pediatric Pneumonia
    Scheier, Eric
    Zimmerman, Deena
    CLINICAL PEDIATRICS, 2020, 59 (02) : 216 - 217
  • [24] Radiography in pediatric dental practice
    Johan Aps
    Clinical Dentistry Reviewed, 4 (1):
  • [25] Pediatric digital radiography education for radiologic technologists: current state
    Morrison, Gregory
    John, Susan D.
    Goske, Marilyn J.
    Charkot, Ellen
    Herrmann, Tracy
    Smith, Susan N.
    Culbertson, John
    Carbonneau, Kira
    PEDIATRIC RADIOLOGY, 2011, 41 (05) : 602 - 610
  • [26] Pediatric digital radiography education for radiologic technologists: current state
    Gregory Morrison
    Susan D. John
    Marilyn J. Goske
    Ellen Charkot
    Tracy Herrmann
    Susan N. Smith
    John Culbertson
    Kira Carbonneau
    Pediatric Radiology, 2011, 41 : 602 - 610
  • [27] Computed radiography in pediatric radiology
    deSilva, M
    SEMINARS IN ROENTGENOLOGY, 1997, 32 (01) : 57 - 63
  • [28] DIGITAL RADIOGRAPHY IN PEDIATRIC ORTHOPEDICS - A PROSPECTIVE, CONTROLLED, AND RANDOMIZED TRIAL
    PHILLIPS, JH
    ALBREGTS, AE
    KLING, TF
    COHEN, MJ
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1994, 14 (03) : 377 - 380
  • [29] Management of pediatric radiation dose using Philips digital radiography
    U. Neitzel
    Pediatric Radiology, 2004, 34 : S227 - S233
  • [30] Pediatric musculoskeletal computed radiography
    S. R. Kottamasu
    Lawrence R. Kuhns
    David A. Stringer
    Pediatric Radiology, 1997, 27 : 563 - 575