Linking brain vascular physiology to hemodynamic response in ultra-high field MRI

被引:96
|
作者
Uludag, Kamil [1 ,4 ]
Blinder, Pablo [2 ,3 ,5 ]
机构
[1] Maastricht Univ, Dept Cognit Neurosci, Fac Psychol & Neurosci, NL-6200 MD Maastricht, Netherlands
[2] Tel Aviv Univ, Sagol Sch Neurosci, Tel Aviv, Israel
[3] Tel Aviv Univ, Dept Neurobiol, George S Wise Fac Life Sci, Tel Aviv, Israel
[4] Oxfordlaan 55, NL-6229 ER Maastricht, Netherlands
[5] Tel Aviv Univ, Dept Neurobiol, George S Wise Fac Life Sci, Sagol Sch Neurosci, Sherman Bldg,Room 418, IL-69978 Tel Aviv, Israel
基金
欧洲研究理事会;
关键词
Ultra-high magnetic field; BOLD signal; Vasculature; Cerebral blood volume; CEREBRAL-BLOOD-FLOW; BOLD POSTSTIMULUS UNDERSHOOT; HIGH-RESOLUTION; FUNCTIONAL MRI; SPIN-ECHO; NEURONAL-ACTIVITY; LAMINAR SPECIFICITY; NEURAL ACTIVITY; VISUAL-CORTEX; INITIAL DIP;
D O I
10.1016/j.neuroimage.2017.02.063
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Functional MRI using blood oxygenation level-dependent (BOLD) contrast indirectly probes neuronal activity via evoked cerebral blood volume (CBV) and oxygenation changes. Thus, its spatio-temporal characteristics are determined by vascular physiology and MRI parameters. In this paper, we focus on the spatial distribution and time course of the fMRI signal and their magnetic field strength dependence. Even though much is still unknown, the following consistent picture is emerging: a) For high spatial resolution imaging, fMRI contrast-to-noise increases supra-linearly with field strength. b) The location and spacing of penetrating arteries and ascending veins in the cortical tissue are not correlated to cortical columns, imposing limitations on achievable point-spread function (PSF) in fMRI. c) Baseline CBV distribution may vary over cortical layers biasing fMRI signal to layers with high CBV values. d) The largest CBV change is in the tissue microvasculature, less in surface arteries and even less in pial veins. e) Venous CBV changes are only relevant for longer stimuli, and oxygenation changes are largest in post-capillary blood vessels. f) The balloon effect (i.e. slow recovery of CBV to baseline) is located in the tissue, consistent with the fact that the post-stimulus undershoot has narrower spatial PSF than the positive BOLD response. g) The onset time following stimulation has been found to be shortest in middle/lower layers, both in optical imaging and high-resolution fMRI, but we argue and demonstrate with simulations that varying signal latencies can also be caused by vascular properties and, therefore, may potentially not be interpreted as neural latencies. With simulations, we illustrate the field strength dependency of fMRI signal transients, such as the adaptation during stimulation, initial dip and the post-stimulus undershoot. In sum, vascular structure and function impose limitations on the achievable PSF of fMRI and give rise to complex fMRI transients, which contain time-varying amount of excitatory and inhibitory neuronal information. Nevertheless, non-invasive fMRI at ultra-high magnetic fields not only provides high contrast-to-noise but also an unprecedented detailed view on cognitive processes in the human brain.
引用
收藏
页码:279 / 295
页数:17
相关论文
共 50 条
  • [41] Mapping functional capillary-weighted blood volume in the human brain using ultra-high field MRI
    Germuska, M.
    Whittaker, J.
    Venzi, M.
    Wise, R. G.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 146 - 146
  • [42] Pulse sequences and parallel imaging for high spatiotemporal resolution MRI at ultra-high field
    Poser, Benedikt A.
    Setsompop, Kawin
    NEUROIMAGE, 2018, 168 : 101 - 118
  • [43] Visualization of microvascular that assumes an ultra-high field MRI with high precision frequency analysis
    Hasegawa, Masaya
    Hirobayashi, Shigeki
    2016 8TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY IN MEDICINE AND EDUCATION (ITME), 2016, : 350 - 354
  • [44] Validation and Optimization of Proximal Femurs Microstructure Analysis Using High Field and Ultra-High Field MRI
    Soldati, Enrico
    Vicente, Jerome
    Guenoun, Daphne
    Bendahan, David
    Pithioux, Martine
    DIAGNOSTICS, 2021, 11 (09)
  • [45] Ultra-High Field Upper Extremity Peripheral Nerve and Non-Contrast Vascular Imaging With 7 Tesla High Resolution MRI
    Raval, Shailesh
    Zhao, Tiejun
    Krishnamurhty, Narayan
    Ibrahim, Tamer
    Gorantla, Vijay
    TRANSPLANTATION, 2015, 99 : S21 - S21
  • [46] Ultra-High Field MRI and Cognitive Dysfunction Associations within an MS Cohort
    Nielsen, A. Scott
    Mainero, Caterina
    Madigan, Nancy
    Kinkel, R. Philip
    NEUROLOGY, 2011, 76 (09) : A258 - A259
  • [47] Leveraging ultra-high field (7T) MRI in psychiatric research
    Calabro, Finnegan J.
    Parr, Ashley C.
    Sydnor, Valerie J.
    Hetherington, Hoby
    Prasad, Konasale M.
    Ibrahim, Tamer S.
    Sarpal, Deepak K.
    Famalette, Alyssa
    Verma, Piya
    Luna, Beatriz
    NEUROPSYCHOPHARMACOLOGY, 2024, 50 (01) : 85 - 102
  • [48] Characterization of spinal cord pathology and its correlates at ultra-high field MRI
    Ouellette, R.
    Treaba, C. A.
    Granberg, T.
    Herranz, E.
    Barletta, V.
    De Leener, B.
    Tauhid, S.
    Yousuf, F.
    Dupont, S.
    Klawiter, E. C.
    Sloane, J. A.
    Bakshi, R.
    Cohen-Adad, J.
    Mainero, C.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 250 - 251
  • [49] Correlation of ultra-high field MRI with histopathology for evaluation of rectal cancer heterogeneity
    Trang T. Pham
    Timothy Stait-Gardner
    Cheok Soon Lee
    Michael Barton
    Petra L. Graham
    Gary Liney
    Karen Wong
    William S. Price
    Scientific Reports, 9
  • [50] Intervertebral disc lesions: visualisation with ultra-high field MRI at 11.7 T
    Nikolaus Berger-Roscher
    Fabio Galbusera
    Volker Rasche
    Hans-Joachim Wilke
    European Spine Journal, 2015, 24 : 2488 - 2495