Multichannel recording of tibial-nerve somatosensory evoked potentials

被引:8
|
作者
de Wassenberg, W. J. G. van [1 ]
Kruizinga, W. J. [1 ]
van der Hoeven, J. H. [1 ]
Leenders, K. L. [1 ]
Maurits, N. M. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Neurol, NL-9700 Groningen, Netherlands
来源
关键词
Somatosensory evoked potential; Amplitude; 128; channel; Butterfly plot; Age;
D O I
10.1016/j.neucli.2008.07.002
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study aims. -The topography of the peaks of tibial.-nerve somatosensory evoked potential (SEP) varies among healthy subjects, most likely because of differences in position and orientation of their cortical generator(s). Therefore, amplitude estimation with a standard one- or two-channel derivation is likely to be inaccurate and might partly cause the low sensitivity of SEP amplitude to pathological changes. In this study, we investigate whether 128-channel tibiat-nerve SEP recordings can improve amplitude estimation and reduce the coefficient of variation. Methods. -We recorded tibial-nerve SEPs using a 128-channel. EEG system in 48 healthy subjects aged 20 to 70 years (47 provided analyzable data). We compared P39, N50, and P60 amplitudes obtained with a 128-channel analysis method (based on butterfly plots and spatial topographies) with those obtained using a one-channel conventional configuration and analysis. Scalp and earlobe references were compared. Results. -Tibial-nerve SEP amplitudes obtained with the 128-channel method were significantly higher as compared to the one-channel conventional method. Consequently, the coefficient of variation was lower for the 128-channel method. In addition, in both methods, the N50-peak amptitude was sometimes hard to identify, because of its low amplitude. Besides, in some subjects, the N50 peak, as obtained with the conventional method, rather seemed to be a period between two positivities rather than an activation peak on itself. Conclusions. -The 128-channel method can measure tibial.-nerve SEP amplitude more accurately and might therefore be more sensitive to pathological changes. Our results indicate that the N50 component is less useful for clinical practice. (c) 2008 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:277 / 288
页数:12
相关论文
共 50 条
  • [31] NASOPHARYNGEAL RECORDING OF SOMATOSENSORY EVOKED-POTENTIALS
    WAGNER, W
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 70 (03): : P74 - P75
  • [32] SUBCORTICAL RECORDING OF SOMATOSENSORY EVOKED-POTENTIALS
    VANDERZANT, CW
    DOMER, PA
    HOOD, TW
    SACKELLARES, JC
    ABOUKHALIL, BW
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1986, 64 (02): : P32 - P32
  • [33] Long latency somatosensory evoked potentials: Modifications after percutaneous tibial nerve stimulation
    Agro, EF
    Petta, F
    Pachatz, C
    Miano, R
    Sciobica, F
    Marfia, GA
    EUROPEAN UROLOGY SUPPLEMENTS, 2006, 5 (02) : 259 - 259
  • [34] Percutaneous tibial nerve stimulation and short latency somatosensory evoked potentials: Preliminary reports
    Adazzi, E.
    Risi, O.
    Spreafico, C.
    Lanza, E.
    EUROPEAN UROLOGY SUPPLEMENTS, 2007, 6 (02) : 141 - 141
  • [35] Alternative anterior reference sites for measuring posterior tibial nerve somatosensory evoked potentials
    John F. Bebawy
    Dhanesh K. Gupta
    Matthew A. Cotton
    Katherine S. Gil
    Edward B. Fohrman
    Srdjan Mirkovic
    Antoun Koht
    Journal of Clinical Monitoring and Computing, 2010, 24 : 107 - 111
  • [36] Time Domain Signal Processing of Tibial Nerve Somatosensory Evoked Potentials During Anesthesia
    Joutsen, A. S.
    Jaentti, V.
    Eskola, H.
    14TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS, 2008, 20 : 458 - +
  • [37] EFFECTS OF STIMULUS-INTENSITY ON POSTERIOR TIBIAL NERVE SOMATOSENSORY EVOKED-POTENTIALS
    RAPPAPORT, M
    PORTILLO, SR
    LEONARD, J
    CLINICAL ELECTROENCEPHALOGRAPHY, 1992, 23 (02): : 89 - 94
  • [38] LUMBAR SPINAL SOMATOSENSORY EVOKED-POTENTIALS IN THE RAT AFTER STIMULATION OF THE TIBIAL NERVE
    WIETHOLTER, H
    HULSER, PJ
    EXPERIMENTAL NEUROLOGY, 1985, 89 (01) : 24 - 31
  • [39] MATURATION OF SOMATOSENSORY EVOKED-POTENTIALS UPON POSTERIOR TIBIAL NERVE-STIMULATION
    MUTOH, K
    OKUNO, T
    MIKAWA, H
    HOJO, H
    PEDIATRIC NEUROLOGY, 1988, 4 (06) : 342 - 349
  • [40] ALTERNATIVE ANTERIOR REFERENCE SITES FOR MEASURING POSTERIOR TIBIAL NERVE SOMATOSENSORY EVOKED POTENTIALS
    Bebawy, John F.
    Gupta, Dhanesh K.
    Cotton, Matthew A.
    Gil, Katherine S.
    Fohrman, Edward B.
    Mirkovic, Srdjan
    Koht, Antoun
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2010, 24 (02) : 107 - 111