The vTAS suite: A simulator for classical and multiplexed three-axis neutron spectrometers

被引:1
|
作者
Boehm, M. [1 ]
Filhol, A. [1 ]
Raoul, Y. [1 ,2 ]
Kulda, J. [1 ]
Schmidt, W. [2 ]
Schmalzl, K. [2 ]
Farhi, E. [1 ]
机构
[1] Inst Max Von Laue Paul Langevin, F-38042 Grenoble 9, France
[2] Outstn Inst Laue Langevin, Forschungszentrum Julich, Julich Ctr Neutron Sci, F-38042 Grenoble, France
关键词
Neutron; TAS; Three axis spectrometer; Inelastic scattering; Instrument control; Instrument simulation; Instrument resolution function;
D O I
10.1016/j.nima.2012.08.050
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The vTAS suite provides graphical assistance to prepare and perform inelastic neutron scattering experiments on a TAS instrument, including latest multiplexed instrumental configurations, such as FlatCone, IMPS and UFO. The interactive display allows for flexible translation between instrument positions in real space and neutron scattering conditions represented in reciprocal space. It is a platform independent public domain software tool, available for download from the website of the Institut Laue Langevin (ILL). (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 44
页数:5
相关论文
共 50 条
  • [31] Design, Manufacturing, and Test of a Real-Time, Three-Axis Magnetic Field Simulator
    Piergentili, Fabrizio
    Candini, Gian Paolo
    Zannoni, Marco
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2011, 47 (02) : 1369 - 1379
  • [32] General kinematics model and coupling movement analysis for a three-axis centrifuge motion simulator
    Zhang Y.
    Zhang S.
    Chen S.
    Zhang X.
    Zhang, Yahong (zyhxjtu@mail.xjtu.edu.cn), 1600, Chinese Mechanical Engineering Society (52): : 135 - 140
  • [33] Three-axis hip joint simulator for wear and friction studies on total hip prostheses
    Saikko, Vesa O.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996, 210 (03) : 175 - 185
  • [34] DEVELOPMENT AND LABORATORY EXPERIMENTATION OF A MAGNETORQUER CONTROL SYSTEM FOR CUBESAT USING A THREE-AXIS SIMULATOR
    Cervettini, Guglielmo
    Park, Hyeongjun
    Lee, Dae Young
    Pastorelli, Stefano
    Romano, Marcello
    ASTRODYNAMICS 2018, PTS I-IV, 2019, 167 : 2649 - 2658
  • [35] Curved-crystal three-axis neutron spectrometry with position sensitive detection
    Popovici, M
    Stoica, A
    Yelon, W
    Berliner, R
    EUV, X-RAY, AND NEUTRON OPTICS AND SOURCES, 1999, 3767 : 320 - 327
  • [36] Monte carlo simulation and optimization of three-axis neutron spectrometer for the PIK reactor
    R. G. Burkovskiĭ
    S. B. Vakhrushev
    O. I. Zvorykina
    A. A. Naberezhnov
    N. M. Okuneva
    A. V. Filimonov
    Crystallography Reports, 2007, 52 : 552 - 557
  • [37] 3He filter on a polarized thermal neutron three-axis spectrometer
    Kulda, J.
    Wildes, A.
    Martin-Martin, A.
    Muller, W.
    Heil, W.
    Humblot, H.
    Tasset, F.
    Physica B: Condensed Matter, 1997, 241-243 : 136 - 138
  • [38] Monte Carlo simulation and optimization of three-axis neutron spectrometer for the PIK reactor
    Burkovskii, R. G.
    Vakhrushev, S. B.
    Zvorykina, O. I.
    Naberezhnov, A. A.
    Okuneva, N. M.
    Filimonov, A. V.
    CRYSTALLOGRAPHY REPORTS, 2007, 52 (03) : 552 - 557
  • [39] The 3He filter on a polarized thermal neutron three-axis spectrometer
    Kulda, J
    Wildes, A
    Martin-Martin, A
    Muller, W
    Heil, W
    Humblot, H
    Tasset, F
    PHYSICA B, 1997, 241 : 136 - 138
  • [40] High-Resolution Strain/Stress Measurements by Three-Axis Neutron Diffractometer
    Mikula, Pavol
    Ryukhtin, Vasyl
    Saroun, Jan
    Strunz, Pavel
    MATERIALS, 2020, 13 (23) : 1 - 7