In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging

被引:4
|
作者
Ganguly, A. [1 ]
Fieselmann, A. [2 ,3 ,4 ]
Boese, J. [4 ]
Rohkohl, C. [2 ,4 ]
Hornegger, J. [2 ,3 ]
Fahrig, R. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, D-91058 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Erlangen Grad Sch Adv Opt Technol SAOT, D-91058 Erlangen, Germany
[4] Siemens AG, Healthcare Sect, D-91301 Forchheim, Germany
基金
美国国家卫生研究院;
关键词
perfusion CT; C-arm; conebeam CT; interventional imaging; x-ray; arterial input function; venous input function; sinusoid; HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; RECONSTRUCTION; STROKE;
D O I
10.1118/1.4757910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors have developed a method to enable cerebral perfusion CT imaging using C-arm based conebeam CT (CBCT). This allows intraprocedural monitoring of brain perfusion during treatment of stroke. Briefly, the technique consists of acquiring multiple scans (each scan comprised of six sweeps) acquired at different time delays with respect to the start of the x-ray contrast agent injection. The projections are then reconstructed into angular blocks and interpolated at desired time points. The authors have previously demonstrated its feasibility in vivo using an animal model. In this paper, the authors describe an in vitro technique to evaluate the accuracy of their method for measuring the relevant temporal signals. Methods: The authors' evaluation method is based on the concept that any temporal signal can be represented by a Fourier series of weighted sinusoids. A sinusoidal phantom was developed by varying the concentration of iodine as successive steps of a sine wave. Each step corresponding to a different dilution of iodine contrast solution contained in partitions along a cylinder. By translating the phantom along the axis at different velocities, sinusoidal signals at different frequencies were generated. Using their image acquisition and reconstruction algorithm, these sinusoidal signals were imaged with a C-arm system and the 3D volumes were reconstructed. The average value in a slice was plotted as a function of time. The phantom was also imaged using a clinical CT system with 0.5 s rotation. C-arm CBCT results using 6, 3, 2, and 1 scan sequences were compared to those obtained using CT. Data were compared for linear velocities of the phantom ranging from 0.6 to 1 cm/s. This covers the temporal frequencies up to 0.16 Hz corresponding to a frequency range within which 99% of the spectral energy for all temporal signals in cerebral perfusion imaging is contained. Results: The errors in measurement of temporal frequencies are mostly below 2% for all multiscan sequences. For single scan sequences, the errors increase sharply beyond 0.10 Hz. The amplitude errors increase with frequency and with decrease in the number of scans used. Conclusions: Our multiscan perfusion CT approach allows low errors in signal frequency measurement. Increasing the number of scans reduces the amplitude errors. A two-scan sequence appears to offer the best compromise between accuracy and the associated total x-ray and iodine dose. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4757910]
引用
收藏
页码:6652 / 6659
页数:8
相关论文
共 50 条
  • [31] Clinical Workflow Evaluation of High -Performance Imaging on a C-Arm Linear Accelerator
    Handschuh, R.
    DiCostanzo, D. J.
    Ramani, M.
    Gupta, N.
    Cetnar, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E534 - E535
  • [32] Comparison of C-arm CT and standard imaging in osteosyntheses of fractured distal radius specimens
    Wirth, S.
    Euler, E.
    Kotsianos-Hermle, D.
    Treitl, M.
    Linsenmaier, U.
    Pfeifer, K-J
    Reiser, M.
    Mutschler, W.
    UNFALLCHIRURG, 2007, 110 (01): : 41 - 48
  • [33] Accuracy of CT Cerebral Perfusion Imaging in Demonstrating Ischemia: A Correlation of the Size of Ischemic Lesions on CT perfusion Compared With Diffusion-Weighted Imaging
    Ho, C.
    Hussain, S.
    Alam, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [34] Sequential intrinsic and extrinsic geometry calibration in fluoro CT imaging with a mobile C-arm
    Cheryauka, Arvi
    Breham, Sebastien
    Christensen, Wayne
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [35] A review of the image segmentation and registration methods in liver motion correction in C-arm perfusion imaging
    Haseljic, Hana
    Frysch, Robert
    Kulvait, Vojtech
    Rose, Georg
    2019 XXVII INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION AND AUTOMATION TECHNOLOGIES (ICAT 2019), 2019,
  • [36] Motion Compensation Using Range Imaging in C-Arm Cone-Beam CT
    Bier, Bastian
    Unberath, Mathias
    Geimer, Tobias
    Maier, Jennifer
    Gold, Garry
    Levenston, Marc
    Fahrig, Rebecca
    Maier, Andreas
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017), 2017, 723 : 561 - 570
  • [37] Miniature C-arm imaging: An in vitro study of detecting foreign bodies in the emergency department
    Cohen, DM
    Garcia, CT
    Dietrich, AM
    Hickey, RW
    PEDIATRIC EMERGENCY CARE, 1997, 13 (04) : 247 - 249
  • [38] Development of intraoperative C-arm imaging in trauma surgery
    Krettek, C.
    Gebhard, F.
    UNFALLCHIRURG, 2012, 115 (02): : 100 - 106
  • [39] Technical Feasibility of CT Perfusion using a C-Arm CBCT System
    Xu, Min
    Tang, Jie
    Royalty, Kevin
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [40] A Filter Model to Analyze Reconstruction Artifacts in Perfusion C-arm CT
    Fieselmann, Andreas
    Dennerlein, Frank
    Deuerling-Zheng, Yu
    Boese, Jan
    Fahrig, Rebecca
    Hornegger, Joachim
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2239 - 2242