The use of a continuous glucose monitoring system in hypoglycemic disorders

被引:3
|
作者
Conrad, SC
Mastrototaro, JJ
Gitelman, SE
机构
[1] Univ Calif San Francisco, Dept Pediat, San Francisco, CA 94143 USA
[2] Medtron Minimed, Northridge, CA USA
来源
关键词
hypoglycemia; continuous glucose monitoring; sensor;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the use of a continuous glucose monitoring system (CGMS) in the evaluation and treatment of infants and children with hypoglycemic disorders. Methods: Patients with hypoglycemic disorders wore the CGMS device in the Pediatric Clinic Research Center during their evaluation and treatment. Capillary blood glucose (CBG) values were obtained at least 3 times each day and entered into the device for calibration purposes. We evaluated the number of hypoglycemic episodes below 3.3 mmol/l (60 mg/dl) detected by CGMS compared to CBG values and characterized episodes by their duration and intensity. Results: Five patients with hypoglycemic disorders were included in the study. There were a total of 13,369 sensor points, 343 paired sensor and CBG data points, and 57 days included. A total of 180 episodes of hypoglycemia occurred in these five patients, with an average duration of 55 +/- 13 minutes. Using a cut-off of 3.3 mmol/l (60 mg/dl) for hypoglycemia, the sensor had a sensitivity of 65.4%, specificity of 90.6%, and false positive rate of 42.9%. The positive and negative predictive values were 57.1% and 93.2%, respectively. Conclusion: CGMS is a useful adjunct in the diagnosis and evaluation of hypoglycemia, and for documentation of euglycemia in these patients following therapy.
引用
收藏
页码:281 / 288
页数:8
相关论文
共 50 条
  • [31] Use of continuous glucose monitoring in children and adolescents
    Phillip, Moshe
    Danne, Thomas
    Shalitin, Shlomit
    Buckingham, Bruce
    Laffel, Lori
    Tamborlane, William
    Battelino, Tadej
    PEDIATRIC DIABETES, 2012, 13 (03) : 215 - 228
  • [32] Continuous Glucose Monitoring Use and Access Disparities
    Chu, Po-Jui
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 326 (14): : 1438 - 1438
  • [33] Routine use of personal continuous glucose monitoring system with insulin pump in Sweden
    Lynch, P.
    Attvall, S.
    Persson, S.
    Barsoe, C.
    Gerdtham, U.
    DIABETOLOGIA, 2012, 55 : S432 - S432
  • [34] Feasibility to use a continuous glucose monitoring system to manage diabetes during hospitalisation
    Bytyqi, Kujtim
    Baumann, Petra Martina
    Hochfellner, Daniel
    Aberer, Felix
    Simic, Amra
    Treiber, Gerlies
    Pottler, Tina
    Hoell, Bernhard
    Fahrleitner-Pammer, Astrid
    Beck, Peter
    Mader, Julia
    WIENER KLINISCHE WOCHENSCHRIFT, 2021, 133 (SUPPL 6) : 211 - 212
  • [35] Evaluation of a non-invasive, continuous glucose monitoring system in patients with diabetes: results of a glucose clamp study with hypoglycemic and hyperglycemic excursions.
    Caduff, A
    Buschor, S
    Dewarrat, R
    Schrepfer, T
    Nosek, L
    Heise, T
    Kapitza, C
    Heinemann, L
    DIABETOLOGIA, 2003, 46 : A45 - A45
  • [36] Continuous glucose monitoring system for congenital hyperinsulinemia
    Md. Saif
    Akshay Kapoor
    IPS Kochar
    Radhika Jindal
    Indian Pediatrics, 2013, 50 : 421 - 422
  • [37] Continuous glucose monitoring system for diabetic cats
    Ristic, J
    Herrtage, M
    Slater, L
    Church, D
    Catchpole, B
    VETERINARY RECORD, 2003, 152 (01) : 28 - 28
  • [38] CONTINUOUS GLUCOSE MONITORING SYSTEM AND CYSTIC FIBROSIS
    Mei Hsia, Mariana Zorron
    Goncalves, Aline C.
    Morcillo, Andre Moreno
    Minicucci, Walter J.
    Ribeiro, Jose D.
    Ribeiro, Antonio F.
    HORMONE RESEARCH IN PAEDIATRICS, 2017, 88 : 173 - 173
  • [39] Continuous glucose monitoring system (CGMS) in hypoglycemia
    Harwood, K
    Aponte, L
    Rincon, M
    DiMartino-Nardi, J
    Muzumdar, R
    Saenger, P
    PEDIATRIC RESEARCH, 2004, 55 (04) : 149A - 149A
  • [40] The MiniMed Continuous Glucose Monitoring System (CGMS)
    Mastrototaro, J
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 1999, 12 : 751 - 758