The use of a continuous glucose monitoring system in hypoglycemic disorders

被引:3
|
作者
Conrad, SC
Mastrototaro, JJ
Gitelman, SE
机构
[1] Univ Calif San Francisco, Dept Pediat, San Francisco, CA 94143 USA
[2] Medtron Minimed, Northridge, CA USA
来源
关键词
hypoglycemia; continuous glucose monitoring; sensor;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the use of a continuous glucose monitoring system (CGMS) in the evaluation and treatment of infants and children with hypoglycemic disorders. Methods: Patients with hypoglycemic disorders wore the CGMS device in the Pediatric Clinic Research Center during their evaluation and treatment. Capillary blood glucose (CBG) values were obtained at least 3 times each day and entered into the device for calibration purposes. We evaluated the number of hypoglycemic episodes below 3.3 mmol/l (60 mg/dl) detected by CGMS compared to CBG values and characterized episodes by their duration and intensity. Results: Five patients with hypoglycemic disorders were included in the study. There were a total of 13,369 sensor points, 343 paired sensor and CBG data points, and 57 days included. A total of 180 episodes of hypoglycemia occurred in these five patients, with an average duration of 55 +/- 13 minutes. Using a cut-off of 3.3 mmol/l (60 mg/dl) for hypoglycemia, the sensor had a sensitivity of 65.4%, specificity of 90.6%, and false positive rate of 42.9%. The positive and negative predictive values were 57.1% and 93.2%, respectively. Conclusion: CGMS is a useful adjunct in the diagnosis and evaluation of hypoglycemia, and for documentation of euglycemia in these patients following therapy.
引用
收藏
页码:281 / 288
页数:8
相关论文
共 50 条
  • [1] Frequency of Hypoglycemic Events before and during Diabetes Camp: Use of a Continuous Glucose Monitoring System
    Kalladi, Shabana
    Degnan, Bernard M.
    Szpunar, Susan
    ENDOCRINE REVIEWS, 2014, 35 (03)
  • [2] Detection of hypoglycemic events with the FreeStyle navigator® continuous glucose monitoring system
    McGarraugh, Geoffrey
    DIABETES, 2007, 56 : A110 - A110
  • [3] Continuous glucose monitoring system in the screening of glucose disorders in cystic fibrosis
    Martin-Frias, M.
    Lamas Ferreiro, A.
    Colino Alcol, E.
    Alvarez Gomez, M. A.
    Yelmo Valverde, R.
    Barrio Castellanos, R.
    ANALES DE PEDIATRIA, 2009, 70 (02): : 120 - 125
  • [4] Continuous glucose monitoring system with an alarm: A tool to reduce hypoglycemic episodes in pregnancy with diabetes
    Worm, Dorte
    Nielsen, Lene Ringholm
    Mathiesen, Elisabeth R.
    Norgaard, Kirsten
    DIABETES CARE, 2006, 29 (12) : 2759 - 2760
  • [5] The use of continuous glucose monitoring in the practical management of glycogen storage disorders
    White, Fiona J.
    Jones, Simon A.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2011, 34 (03) : 631 - 642
  • [6] Use of Continuous Glucose Monitoring System in the Management of Severe Hypoglycemia
    Ryan, Edmond A.
    Germsheid, Judy
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (10) : 635 - 639
  • [7] Validation of a Continuous Glucose Monitoring System for Use in Dogs and Pigs
    Wiedmeyer, C. E.
    Johnson, P. J.
    Fangman, T. J.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2009, 48 (05): : 552 - 552
  • [8] Use of Continuous Glucose Monitoring Does Not Alter Hypoglycemic Awareness in Patients with Type 2 Diabetes Mellitus
    Mehfooz, Ayesha
    Lee, Yee Liong
    Wang, Qi
    Chow, Lisa S.
    DIABETES, 2022, 71
  • [9] High Performance of a Novel Sensor for Continuous Glucose Monitoring in the Hypoglycemic Range
    Obermaier, Karin
    Schmelzeisen-Redeker, Guenther
    Schoemaker, Michael
    Zschornack, Eva
    Freckmann, Guido
    DIABETES, 2013, 62 : A44 - A44
  • [10] The Continuous Glucose Monitoring System (CGMS) in type 1 diabetic children is the way to reduce hypoglycemic risk
    Schiaffini, R
    Ciampalini, P
    Fierabracci, A
    Spera, S
    Borrelli, P
    Bottazzo, GF
    Crinò, A
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2002, 18 (04) : 324 - 329