摘要
Several models were developed in the literatures for studying the system impedance characteristics during sub-synchronous oscillations (SSO). However, the doubly-fed induction generator (DFIG) impedance presents a 2 x 2 matrix with the frequency coupling component at the off-diagonal position, which increases the difficulty for analyzing the impedance characteristics of DFIG. The coupling effect in this case is caused by the asymmetric impedance characteristics of controllers, which are composed of voltage source converters (VSCs). Accordingly, simplifications are often conducted to decouple the impedance matrix into single sequences. Outer loop controller and phase-locked loop (PLL), which are often neglected in simplifications, are the main causes of the asymmetry of impedance matrix. Such simplifications could also hamper proper system stability analyses. In this paper, a comprehensive impedance model is proposed in which the outer loop controller, PLL, and grid-side controller (GSC) are all considered. The proposed comprehensive impedance model can provide exact stability data, in which stable boundaries for compensation level and transmission distances are presented. Furthermore, the proposed model is converted to simplified models in which the impacts of outer loop controller, PLL, GSC and coupling components on boundary stability of SSO are analyzed. The results are validated by time domain simulations and eigenvalue analyses, and deviations of the simplified models are analyzed for different operating parameters and conditions leading to simplifications.
引用
收藏
页码:158380 / 158390
页数:11
相关论文
共 50 条
  • [21] Oscillation analysis of a DFIG-based wind farm interfaced with LCC-HVDC
    Yang Lin
    Xiao XiangNing
    Pang ChengZong
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2014, 57 (12) : 2453 - 2465
  • [22] Contribution of DFIG-Based Wind Farm to System Frequency Control
    Aktarujjaman, M.
    Haque, M. E.
    Negnevitsky, M.
    2012 7TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2012,
  • [23] Layered VAR Control Strategy of DFIG-based Wind Farm
    Zhou Xia
    Yang Weidong
    Wang Songyan
    Chen Ning
    2009 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS, 2009, : 58 - +
  • [24] Analysis and mitigation of subsynchronous resonance based on integral control for DFIG-based wind farm
    Meng, Yongqing
    Pan, Xixi
    Ma, Hao
    Li, Kaikai
    Yu, Jianyang
    Wang, Xiuli
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (09) : 1718 - 1725
  • [25] Comprehensive Impedance Analysis of DFIG-Based Wind Farms Considering Dynamic Couplings
    Wang, Jinlong
    Wang, Peng
    Zhao, Haoran
    Yang, Futao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (01) : 2259 - 2272
  • [26] Impedance Spectroscopy Failure Diagnosis of a DFIG-Based Wind Turbine
    Becherif, Mohamed
    Henni, Assia
    Benbouzid, Mohamed
    Wack, Maxime
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 4310 - 4315
  • [27] Equivalent modeling and multi-parameter coupling optimization for DFIG-based wind farms considering SSO mode
    Zhang, Qian
    Jin, Xuyang
    Zhang, Fan
    Yuan, Hao
    Zhou, Baorong
    FRONTIERS IN ENERGY RESEARCH, 2023, 10
  • [28] Supplementary Loop in BESS Control Scheme for SSO Mitigation in DFIG-Based Wind Farms
    Moreno-Sanchez, R.
    Visairo-Cruz, N.
    Nunez-Gutierrez, A.
    Hernandez-Ramirez, J.
    Segundo-Ramirez, J.
    IEEE LATIN AMERICA TRANSACTIONS, 2024, 22 (12) : 1054 - 1062
  • [29] Nonlinear dynamic modeling for fault ride-through capability of DFIG-based wind farm
    M. Kenan Döşoğlu
    Nonlinear Dynamics, 2017, 89 : 2683 - 2694
  • [30] Modeling and Control of Gate-Controlled Series Capacitor Interfaced With a DFIG-Based Wind Farm
    Mohammadpour, Hossein Ali
    Santi, Enrico
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (02) : 1022 - 1033