Manganese-52 positron emission tomography tracer characterization and initial results in phantoms and in vivo

被引:46
|
作者
Topping, Geoffrey J. [1 ]
Schaffer, Paul [2 ]
Hoehr, Cornelia [2 ]
Ruth, Thomas J. [2 ]
Sossi, Vesna [1 ]
机构
[1] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 2B5, Canada
[2] TRIUMF, Nucl Med, Vancouver, BC V6T 2A3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Manganese-52; PET; MANGANESE-ENHANCED MRI; BRAIN; ACTIVATION; SIMULATION; EMITTERS; CHROMIUM; SCANNER;
D O I
10.1118/1.4793756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Manganese(II) is employed as a contrast agent with magnetic resonance imaging (MRI) for study of neuronal activation in rats and mice. However, at the concentrations required for MRI, Mn may induce pharmacological or toxic effects. Positron emission tomography (PET) imaging of (MnCl2)-Mn-52 at tracer doses has the potential to allow similar Mn studies as manganese-enhanced MRI while providing quantitative results and avoiding toxic effects. In this work, (MnCl2)-Mn-52 is produced and characterized as a PET tracer in phantoms and in rats. Methods: (MnCl2)-Mn-52 was produced by proton irradiation of natural Cr foil and separated by column chromatography. Images were acquired on a Siemens Focus 120 small animal PET scanner. Phantom images were acquired to assess uniformity, resolution, cascade background correction, and count rate linearity. Images of rats were also acquired after systemic and intracerebroventricular (ICV) administration of (MnCl2)-Mn-52 to investigate Mn(II) distribution in vivo. Results: Irradiation yield was 74.6 +/- 8.5 kBq/mu A min Mn-52 at end of bombardment with initial specific activity of at least 3.5 MBq/nmol. Mn-52 PET images show similar uniformity and resolution to F-18. F-18 based detector efficiency normalization is adequate for Mn-52 imaging. Subtraction of a rescaled random events distribution from sinogram data is effective for cascade correction of Mn-52 PET data. After systemic injection, Mn-52 appears in structures throughout the body of rats, including bones, liver, intestines, and the pituitary gland, but does not appear detectably throughout the brain. After ICY injection, Mn-52 remains in the brain and spinal cord. Conclusions: Mn-52 is a promising tracer for small animal PET imaging, yielding image quality comparable to F-18. Potential applications include studies similar to Mn-enhanced neuronal MRI, and in other organ systems including bones, spinal cord, and the digestive tract. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4793756]
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Positron emission tomography for modeling pathophysiological processes in vivo
    Hendrikse, N. Harry
    Luurtsema, Gert
    van der Veldt, Astrid A. M.
    Lubberink, Mark
    CURRENT OPINION IN DRUG DISCOVERY & DEVELOPMENT, 2008, 11 (05) : 717 - 725
  • [42] Use of positron emission tomography to study tumors in vivo
    Hamberg, LM
    Hunter, GJ
    Fischman, AJ
    MOLECULAR MEDICINE TODAY, 1996, 2 (12): : 528 - 534
  • [43] Imaging Biotin Trafficking In Vivo with Positron Emission Tomography
    Bongarzone, Salvatore
    Sementa, Teresa
    Dunn, Joel
    Bordoloi, Jayanta
    Sunassee, Kavitha
    Blower, Philip J.
    Gee, Antony
    JOURNAL OF MEDICINAL CHEMISTRY, 2020, 63 (15) : 8265 - 8275
  • [44] Initial characterization of a PDE10A selective positron emission tomography tracer [11C]AMG 7980 in non-human primates
    Hwang, Dah-Ren
    Hu, Essa
    Rumfelt, Shannon
    Easwaramoorthy, Balu
    Castrillon, John
    Davis, Carl
    Allen, Jennifer R.
    Chen, Hang
    Treanor, James
    Abi-Dargham, Anissa
    Slifstein, Mark
    NUCLEAR MEDICINE AND BIOLOGY, 2014, 41 (04) : 343 - 349
  • [45] Positron emission tomography radioligands for in vivo imaging of Aβ plaques
    Mason, N. Scott
    Mathis, Chester A.
    Klunk, William E.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2013, 56 (3-4): : 89 - 95
  • [46] In vivo labeling of serum albumin for positron emission tomography
    Niu, Gang
    Lang, Lixin
    Kiesewetter, Dale
    Ma, Ying
    Chen, Xiaoyuan
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [47] In vivo imaging of oligonucleotides with positron emission tomography.
    Tavitian, B
    Marzabal, S
    Kühnast, B
    Dollé, F
    Terrazzino, S
    Deverre, JR
    Jobert, A
    Hinnen, F
    Bendriem, B
    Crouzel, C
    Di Giamberardino, L
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 229P - 229P
  • [48] Multi-Tracer Positron Emission Tomography Quantification of Sympathetic Innervation Tracer Similarity But Not Equivalence
    Sinusas, Albert J.
    Liu, Chi
    JACC-CARDIOVASCULAR IMAGING, 2021, 14 (07) : 1437 - 1439
  • [49] INITIAL CHARACTERIZATION OF A BGO-PHOTODIODE DETECTOR FOR HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY
    DERENZO, SE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 620 - 626
  • [50] 18F-fluorodeoxyglucose positron emission tomography for characterization and initial staging of pancreatic tumors
    Valinas, R
    Barrier, A
    Montravers, F
    Houry, S
    Talbot, JN
    Huguier, M
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 2002, 26 (10): : 888 - 892