Manganese-52 positron emission tomography tracer characterization and initial results in phantoms and in vivo

被引:46
|
作者
Topping, Geoffrey J. [1 ]
Schaffer, Paul [2 ]
Hoehr, Cornelia [2 ]
Ruth, Thomas J. [2 ]
Sossi, Vesna [1 ]
机构
[1] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 2B5, Canada
[2] TRIUMF, Nucl Med, Vancouver, BC V6T 2A3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Manganese-52; PET; MANGANESE-ENHANCED MRI; BRAIN; ACTIVATION; SIMULATION; EMITTERS; CHROMIUM; SCANNER;
D O I
10.1118/1.4793756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Manganese(II) is employed as a contrast agent with magnetic resonance imaging (MRI) for study of neuronal activation in rats and mice. However, at the concentrations required for MRI, Mn may induce pharmacological or toxic effects. Positron emission tomography (PET) imaging of (MnCl2)-Mn-52 at tracer doses has the potential to allow similar Mn studies as manganese-enhanced MRI while providing quantitative results and avoiding toxic effects. In this work, (MnCl2)-Mn-52 is produced and characterized as a PET tracer in phantoms and in rats. Methods: (MnCl2)-Mn-52 was produced by proton irradiation of natural Cr foil and separated by column chromatography. Images were acquired on a Siemens Focus 120 small animal PET scanner. Phantom images were acquired to assess uniformity, resolution, cascade background correction, and count rate linearity. Images of rats were also acquired after systemic and intracerebroventricular (ICV) administration of (MnCl2)-Mn-52 to investigate Mn(II) distribution in vivo. Results: Irradiation yield was 74.6 +/- 8.5 kBq/mu A min Mn-52 at end of bombardment with initial specific activity of at least 3.5 MBq/nmol. Mn-52 PET images show similar uniformity and resolution to F-18. F-18 based detector efficiency normalization is adequate for Mn-52 imaging. Subtraction of a rescaled random events distribution from sinogram data is effective for cascade correction of Mn-52 PET data. After systemic injection, Mn-52 appears in structures throughout the body of rats, including bones, liver, intestines, and the pituitary gland, but does not appear detectably throughout the brain. After ICY injection, Mn-52 remains in the brain and spinal cord. Conclusions: Mn-52 is a promising tracer for small animal PET imaging, yielding image quality comparable to F-18. Potential applications include studies similar to Mn-enhanced neuronal MRI, and in other organ systems including bones, spinal cord, and the digestive tract. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4793756]
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Initial Imaging Results with Manganese-52 PET Tracer
    Topping, G. J.
    Schaffer, P.
    Sossi, V.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [2] Quantitative evaluation of manganese-52m as a myocardial perfusion tracer in pigs using positron emission tomography
    Buck, A
    Nguyen, N
    Burger, C
    Ziegler, S
    Frey, L
    Weigand, G
    Erhardt, W
    SenekowitschSchmidtke, R
    Pellikka, R
    Blauenstein, P
    Locher, JT
    Schwaiger, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (12): : 1619 - 1627
  • [3] Quantitative evaluation of manganese-52m as a myocardial perfusion tracer in pigs using positron emission tomography
    Buck, A.
    Nguyen, N.
    Burger, C.
    Ziegler, S.
    Frey, L.
    Weigand, G.
    Erhardt, W.
    Senekowitsch-Schmidtke, R.
    Pellikka, R.
    Bläuenstein, P.
    Locher, J.T.
    Schwaiger, M.
    European Journal of Nuclear Medicine and Molecular Imaging, 1996, 23 (12): : 1619 - 1627
  • [4] POSITRON EMISSION TOMOGRAPHY TRACER TECHNIQUES
    RAICHLE, ME
    ADVANCES IN CHEMISTRY SERIES, 1981, (197): : 420 - +
  • [5] POSITRON EMISSION TOMOGRAPHY IN MANGANESE INTOXICATION
    WOLTERS, EC
    HUANG, CC
    CLARK, C
    PEPPARD, RF
    OKADA, J
    CHU, NS
    ADAM, MJ
    RUTH, TJ
    LI, D
    CALNE, DB
    ANNALS OF NEUROLOGY, 1989, 26 (05) : 647 - 651
  • [6] Synthesis and In Vivo Evaluation of the Novel Tracer for Positron Emission Tomography Imaging of Tumor Senescence
    Cotton, Jonathan
    Kuehn, Anna
    Fuchs, Kerstin
    Maurer, Andreas
    Pichler, Bernd J.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2015, 58 : S53 - S53
  • [7] Computed tomography, positron emission tomography, positron emission tomography/computed tomography, and magnetic resonance imaging for staging of limited pleural mesothelioma - Initial results
    Plathow, Christian
    Staab, Adrian
    Schmaehl, Astrid
    Aschoff, Philip
    Zuna, Ivan
    Pfannenberg, Christina
    Peter, Schlemmer Heinz
    Eschmann, Susanne
    Klopp, Michael
    INVESTIGATIVE RADIOLOGY, 2008, 43 (10) : 737 - 744
  • [8] MYOCARDIAL POSITRON TOMOGRAPHY WITH MANGANESE-52M
    ATKINS, HL
    SOM, P
    FAIRCHILD, RG
    HUI, J
    SCHACHNER, E
    GOLDMAN, A
    KU, T
    RADIOLOGY, 1979, 133 (03) : 769 - 774
  • [9] MANGANESE-52M POSITRON EMISSION TRANSAXIAL TOMOGRAPHY FOR DETECTING MYOCARDIAL-INFARCTION
    HUI, JCK
    ATKINS, HL
    SOM, P
    KU, TH
    FAIRCHILD, RG
    GIWA, LO
    RICHARDS, P
    JOURNAL OF NUCLEAR MEDICINE, 1979, 20 (06) : 648 - 648
  • [10] In vivo characterization of inhaled pharmaceuticals using quantitative positron emission tomography
    Berridge, MS
    Heald, DL
    JOURNAL OF CLINICAL PHARMACOLOGY, 1999, 39 : 25S - 29S