摘要
We have operated the two 22.9 kV/50 MVA HTS cable systems installed at Gochang Test Yard and Icheon Substation of Korea Electric Power Corporation (KEPCO), respectively; they have a double layer conductor and a single layer shield, consisting of BSCCO and YBCO-NiW wires. In general, the ac loss of a multilayer cylindrical conductor like the KEPCO HTS cables is evaluated from the conductor's current and the loss voltage of a lead soldered onto its outermost layer. To experimentally investigate what the voltage lead on the outermost layer picks up in this study, we prepared a double layer BSCCO conductor sample, and attached the four voltage leads of the outer, inner, contactless, and total leads. Then its ac loss for these leads was examined for different layer current distribution, and finally compared with a numerically calculated one. The results show that the outer-lead, which is often used in the double layer conductors, takes only the outer layer's loss voltage like the contactless-lead. Therefore, for ac loss evaluation of our double layer sample, a new voltage lead, total-lead, is presented besides the conventionally used outer-lead. The total-lead best fits with the numerical calculations, regardless of layer current distribution. However, the outer-lead is not suitable, especially for nonuniform distribution, although it still now is valid only for uniform distribution.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] AC LOSS MEASUREMENT OF SUPERCONDUCTING MAGNETS - INFLUENCE OF THE COMPENSATING SCHEME
    GOMORY, F
    ACTA PHYSICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1982, 53 (3-4): : 433 - 444
  • [32] AC Loss Measurement of the DEMO TF React&Wind Conductor Prototype No. 2
    Sedlak, Kamil
    Bruzzone, Pierluigi
    Stepanov, Boris
    Corato, Valentina
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2020, 30 (04)
  • [33] Ac-loss measurement of a DyBCO-Roebel assembled coated conductor cable (RACC)
    Schuller, S.
    Goldacker, W.
    Kling, A.
    Krempasky, L.
    Schmidt, C.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2007, 463 : 761 - 765
  • [34] Influence of transport modes on AC loss characteristics of cylindrical single-layer conductors consisting of various HTS tapes
    Li, Z. Y.
    Gu, F.
    Ma, Y. H.
    Ryu, K.
    Hong, Z.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2020, 569 (569):
  • [35] A Calculation Method on High-Frequency Loss of Double-Layer Composite Conductor
    Zhang, Mingze
    Liu, Ji
    Liao, Lilin
    Gao, Huan
    Zhu, Dongbai
    Zhuo, Fengfeng
    Qi, Pengshuai
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2018, 60 (03) : 647 - 656
  • [36] The influence of the parameter detuning on the AC harmonic voltage measurement based on filter
    Mao, Tao
    Le, Jian
    Huang, Yinlong
    Luo, Hanwu
    Liu, Kaipei
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2016, 31 (04): : 147 - 154
  • [37] Power frequency AC voltage measurement based on double wound Rogowski coil
    Ibrahim, Mohamed E.
    Abd-Elhady, Amr M.
    HIGH VOLTAGE, 2017, 2 (02): : 129 - 135
  • [38] Influence of the conductor's arrangement and current on the AC loss characteristics of a fault current limiting coil
    Li, Z. Y.
    Ma, Y. H.
    Ryu, K.
    Choi, S.
    Park, K. B.
    Oh, I. S.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2008, 468 (15-20): : 2063 - 2066
  • [39] ANALOG DIGITAL DOUBLE INTEGRATION JOULEMETER FOR AC LOSS MEASUREMENT IN SUPERCONDUCTING MAGNETS
    JANSAK, L
    CHOVANEC, F
    CRYOGENICS, 1980, 20 (03) : 125 - 126
  • [40] Influence of densification of the protective layer on the discharge voltage in AC plasma display panel
    Kim, R
    Kim, Y
    Park, JW
    VACUUM, 2001, 61 (01) : 37 - 43