A slit-end extraction Penning ionization gauge ion source with a permanent magnet

被引:0
|
作者
Song, ZZ [1 ]
Yu, JX [1 ]
Dong, GC [1 ]
Zhang, J [1 ]
Wang, ZG [1 ]
Zhao, WJ [1 ]
机构
[1] Peking Univ, Inst Heavy Ion Phys, Beijing 100871, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2002年 / 73卷 / 02期
关键词
D O I
10.1063/1.1428781
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new slit-end extraction Penning ionization gauge ion source with a SmCo permanent magnet has been developed. The cathode is a 5 mm diam X 25 nun long LaB6 cylinder, the anode with a hole of 8X32 mm is made in stainless steel, and the ion emission hole size on the anticathode is in a range of 14-28X2 mm for the different limited extraction current. The preliminary experiment indicated that the discharge was easy and smooth for this source. More than 10 mA of the total beam current for the positive oxygen ion has been measured at discharge current 200 mA and extraction voltage 25 kV and the milliampere magnitude of the negative oxygen ion beam can be extracted from this source. (C) 2002 American Institute of Physics.
引用
收藏
页码:852 / 853
页数:2
相关论文
共 50 条
  • [41] Diagnosis of plasmas in compact ECR ion source equipped with permanent magnet
    Suzuki, T
    Sawado, Y
    Lida, T
    Fujii, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1520 - 1522
  • [42] Minimono: An ultracompact permanent magnet ion source for singly charged ions
    Gaubert, G
    Baru, C
    Canet, C
    Cornell, J
    Dupuis, M
    Farabolini, W
    Flambard, JL
    Gorel, P
    Jardin, P
    Lecesne, N
    Leherissier, P
    Lemagnen, F
    Leroy, R
    Pacquet, JY
    Saint-Laurent, MG
    Villari, ACC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (02): : 956 - 960
  • [43] Emittance studies of the 2.45 GHz permanent magnet ECR ion source
    Zelenak, A
    Bogomolov, SL
    Yazvitsky, NY
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1653 - 1655
  • [44] An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy
    Cao, Yun
    Li, Jia Qing
    Sun, Liang Ting
    Zhang, Xue Zhen
    Feng, Yu Cheng
    Wang, Hui
    Ma, Bao Hua
    Li, Xi Xia
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [45] IMPROVED EXTRACTION OF ZIRCONIUM AND MOLYBDENUM BEAMS FROM A PENNING DISCHARGE ION-SOURCE
    LEWIS, MB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 219 (01): : 247 - 249
  • [46] Simulation of Penning ion source with optimized beam extraction system for tagged neutron tube
    Yu, Zitong
    Zhao, Sijia
    Guo, Wenting
    Zheng, Yulai
    Jing, Shiwei
    Zhang, Wenjuan
    OPTIK, 2020, 213 (213):
  • [47] A COLD-HOLLOW-CATHODE LATERAL-EXTRACTION PENNING ION-SOURCE
    MA, M
    MYNARD, JE
    SEALY, BJ
    STEPHENS, KG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 55 (1-4): : 335 - 338
  • [48] Sufficient cusp field generated by permanent magnet for compact ECR ion source
    Rashid, MH
    Bhandari, RK
    INDIAN JOURNAL OF PHYSICS, 2004, 78 (09) : 955 - 959
  • [49] Design of a Prototype Positive Ion Source with Slit Aperture Type Extraction System
    Sharma, Sanjeev K.
    Vattilli, Prahlad
    Choksi, Bhargav
    Punyapu, Bharathi
    Sidibomma, Rambabu
    Bonagiri, Sridhar
    Aggrawal, Deepak
    Baruah, Ujjwal K.
    10TH ASIA PLASMA AND FUSION ASSOCIATION CONFERENCE (APFA), 2017, 823
  • [50] Development of a compact permanent magnet helicon plasma source for ion beam bioengineering
    Kerdtongmee, P.
    Srinoum, D.
    Nisoa, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (10):