Immersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas

被引:2
|
作者
Skrzypecki, Janusz [1 ,2 ]
Grabska-Liberek, Iwona [3 ]
Guszkowska, Maria [1 ]
Izdebska, Justyna [1 ]
Szaflik, Jacek P. [1 ]
机构
[1] Med Univ Warsaw, Dept Ophthalmol, Warsaw, Poland
[2] Med Univ Warsaw, Dept Expt Physiol & Pathophysiol, Warsaw, Poland
[3] Med Ctr Postgrad Educ, Dept Ophthalmol, Warsaw, Poland
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
intraocular lens; intraocular lens power; Barrett Universal formula; cataract; PARTIAL COHERENCE INTERFEROMETRY; CHAMBER DEPTH MEASUREMENT; ACCURACY; EYES;
D O I
10.2147/OPTH.S259078
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Fourth-generation formulas for intraocular lens power calculations, including the Barrett Universal II formula, the Olsen formula or the Holladay 2 formula, were thoroughly validated with optical biometry measurements. They precisely predict the effective lens position not only in normal eyes but also in eyes with unusual anatomy. However, in the setting of dense nuclear or posterior subcapsular cataracts, optical biometers fail to obtain accurate measurements and third-generation formulas, i.e. the Hoffer Q or the SRK/T, combined with ultrasound measurements are a method of choice. Considering that optical biometry was fine-tuned to immersion ultrasound, we hypothesize that fourth-generation formulas will yield precise intraocular lens power calculations with immersion ultrasound measurements. Methods: We retrospectively analyzed 50 eyes of 50 patients who underwent uneventful cataract surgery. All patients had intraocular lens power calculated based on immersion ultrasound measurements. Refractive error predictions were compared between third-generation formulas and fourth-generation formulas. Results: There were no statistically significant differences in the median absolute error between formulas. In the study, 86%, 88%, 86%, 84%, 88% and 80% of eyes were within 1 D of target refraction for the SRK/T, the Barrett II, the Hoffer Q, the Holladay 1, the Holladay 2 and the Olsen formula respectively. Conclusion: Fourth-generation formulas combined with immersion ultrasound produced similar results to third-generation formulas. However, the percentage of eyes within 1 D of target refraction remains inferior to previously reported results for optical biometry measurements.
引用
收藏
页码:2159 / 2162
页数:4
相关论文
共 50 条
  • [11] Challenges in pediatric cataract surgery: comparison of intraocular lens power calculation formulas using optical biometry
    Yilmaz, Ibrahim Edhem
    Kimyon, Sabit
    Mete, Alper
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (10) : 3071 - 3077
  • [12] Biometry and intraocular lens power calculation for cataract surgery: an update
    Findl, O.
    SPEKTRUM DER AUGENHEILKUNDE, 2007, 21 (02) : 90 - 93
  • [13] Understanding intraocular lens calculation and biometry
    Barrett, Graham D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (12): : 1499 - 1501
  • [14] Comparison of 9 intraocular lens power calculation formulas
    Cooke, David L.
    Cooke, Timothy L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1157 - 1164
  • [15] THEORETICAL FORMULAS FOR INTRAOCULAR-LENS POWER CALCULATION
    AFLALO, G
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1987, 10 (04): : 283 - 293
  • [16] Intraocular Lens Power Calculation Formulas—A Systematic Review
    Wiktor Stopyra
    Achim Langenbucher
    Andrzej Grzybowski
    Ophthalmology and Therapy, 2023, 12 : 2881 - 2902
  • [17] Comparison of 9 modern intraocular lens power calculation formulas for a quadrifocal intraocular lens
    Shajari, Mehdi
    Kolb, Carolin M.
    Petermann, Kerstin
    Boehm, Myriam
    Herzog, Michael
    de'Lorenzo, Nina
    Schoenbrunn, Sabrina
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (08): : 942 - 948
  • [18] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [19] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384
  • [20] Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients
    Lin, Lei
    Fang, Jiayan
    Sun, Weijie
    Gu, Siyi
    Xu, Liming
    Chen, Siping
    Chang, Pingjun
    Zhao, Yun-e
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (04) : 1019 - 1027